Lantronix UDS2100 manual Compliance and Disclaimer

Page 81

D: Compliance and Disclaimer

Manufacturer’s Name & Address

Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA

Declares that the following product:

Product Name Model: UDS2100 Device Server

Conforms to the following standards or other normative documents:

Safety

UL 60950-1

CSA 22.2. No 60950-1-03

EN 60950-1

TUV

VCCI

C-TICK

Electromagnetic Emissions

FCC Part 15 Subpart B Class A

ICES-003 Issue 4 February 2004 Class A

AS/NZS CISPR 22: 2006 Class A

EN55022: 1998 + A1: 2000 + A2: 2003 CLASS A

EN61000-3-2: 2000 Class A

EN61000-3-3: 1995 +A1: 2001

VCCI

V-3/2006.04 Class A

Electromagnetic Immunity

EN55024: 1998 +A1: 2001 +A2: 2003

IEC 61000-4-2: 1995

IEC 61000-4-3: 1995

IEC 61000-4-4: 1995

IEC 61000-4-5: 1995

IEC 61000-4-6: 1996

IEC 61000-4-8: 1993

IEC 61000-4-11: 1994

UDS2100 User Guide

81

Image 81
Contents UDS2100 User Guide Contacts Copyright & TrademarkRevisions Date Rev CommentsContents Setup Mode Server Configuration Warranty Tables FiguresPurpose and Audience Using This GuideChapter Summary Chapter DescriptionDocument Additional DocumentationIntroduction ApplicationsApplication Examples Introduction Additional Features Configuration MethodsProtocol Support Sample Hardware Address 00-20-4A-14-01-18 or 00204A140118 Product Information LabelGetting Started Package ContentsTo install the unit Installing the UDSHardware Address Required InformationIP Address IP Address Subnet Mask GatewayInstalling DeviceInstaller Assigning the IP Address DeviceInstallerAssigning an IP Address Select Assign a specific IP address and click NextViewing the Current Configuration Accessing the UDS2100 Using DeviceInstallerTo view the units current settings Adding the Unit to the Manage ListGetting Started SettingTo configure the unit using a Telnet session Next StepPress Enter within 5 seconds Assigning the IP Address Serial Port Login Accessing UDS2100 Using DeviceInstaller Configuration Using Web ManagerLantronix Web Manager Network ConfigurationAutomatic IP Address Configuration To assign an IP address automaticallySelect Obtain IP address automatically Ethernet Configuration Static IP Address ConfigurationSelect Use the following IP configuration To assign an IP address manuallyTo configure the UDS2100’s device server settings Server ConfigurationServer Configuration AdvancedTo configure the host list Host List ConfigurationSerial Settings Channel 1 and Channel 2 ConfigurationRetry Settings Host InformationChannel Port SettingsFlush Input Buffer Serial to Network Pack ControlConnection Settings TCP To configure a channel’s TCP settingsFlush Output Buffer Network to Serial Connect Mode Active Connection Connect Mode Passive ConnectionEndpoint Configuration Connect ProtocolCommon Options Disconnect ModeConnection Settings UDP To configure a channel’s UDP settingsDatagram Mode Apply Factory Defaults Apply SettingsConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection To establish a Telnet connection Serial Port ConnectionTo exit setup mode Exiting Setup ModeServer Configuration Option Setup Mode Server ConfigurationIP Address Set Gateway IP AddressNetmask Number of Bits for Host Part Change Telnet Configuration PasswordDhcp Name Network Class Host Bits NetmaskSetup Mode Server Configuration Setup Mode Channel Configuration Channel 1 OptionBaudrate Mode Option Interface ModeCommon I/F Mode Setting Binary FlowPort Number Connect ModeFlow Control Option Hex Port Numbers Reserved forConnect Mode Option Incoming Connection ResponseActive Startup Manual Connection Address Example Datagram Type To enable the hostlistModem Mode No Carrier MessageMeaningSend the Escape Sequence +++ in Modem Mode Modem Mode Function CommandAuto Increment Source Port Remote IP Address Disconnect Mode OptionRemote Port DisConnModePack Control Flush Mode Buffer FlushingTrailing Characters Packing IntervalSend Characters OptionChannel Port Password DisConnTime Inactivity TimeoutSend Characters Telnet Terminal TypeSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds Disable Monitor Mode at bootup ARP Cache timeout in secondsEnable alternate MAC Http Port NumberDisable Snmp Security Settings OptionDisable Telnet Setup Snmp Community NameDisable Port 77FE Hex Disable Tftp Firmware UpdateDisable Web Server Disable Web SetupChannel 1 and Channel 2 Configuration Defaults Default Settings OptionExpert Settings Defaults Security Settings DefaultsSetup Mode Advanced Settings Using Tftp Graphical User Interface Firmware UpgradesObtaining Firmware Reloading Firmware ROM FileTo recover firmware Using Tftp Command Line InterfaceFirmware Upgrades Entering Monitor Mode Using the Serial Port Monitor ModeEntering Monitor Mode Using the Network Port Monitor Mode CommandsResponse Meaning Command Command Name FunctionLEDs Troubleshooting and Contact InformationLEDs Meaning Diagnostic, Power, and Serial Port LEDs UDS2100 LEDsProblem/Message Reason Solution Problems and Error MessagesProblem/Message Reason Solution Technical Support Europe, Middle East, and Africa Technical SupportSerial Connector Pinouts Connections and PinoutsUDS2100 Serial Ports Ethernet Connector Pinouts Power Plug Reset ButtonTo reset the unit to factory defaults Network PortCategory Description Technical SpecificationsCategory Description Transient over voltages AutoIP Alternative Ways to Assign an IP AddressTo assign a temporary IP address ARP and TelnetConverting Binary to Hexadecimal Conversion TableDecimal Binary Hex Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index

UDS2100 specifications

The Lantronix UDS2100 is a versatile device server designed to facilitate connections between serial devices and Ethernet networks. This innovative product acts as a bridge, allowing for seamless communication between legacy serial devices and modern IP-based systems. Its importance has grown, particularly in industries that still rely on serial technology but seek to integrate with contemporary IT infrastructures.

One of the main features of the UDS2100 is its ability to connect up to two serial devices simultaneously. This dual-port capability makes it an efficient solution for environments where multiple devices need to be networked without additional complexity. By enabling these connections, the UDS2100 allows for remote control and monitoring of various equipment, leading to increased operational efficiency.

The device supports a variety of communication protocols, including TCP/IP, UDP, and HTTP, ensuring compatibility with a broad range of applications. This flexibility is complemented by the UDS2100’s support for both standard and custom baud rates, making it adaptable to various serial device configurations. Users can configure the device via a web-based interface, simplifying the setup process and enhancing user experience.

In terms of security, the Lantronix UDS2100 is equipped with numerous features to protect data transmission over the network. These include support for Secure Sockets Layer (SSL) and Transport Layer Security (TLS), which encrypt the data being transmitted, ensuring that sensitive information remains protected from potential threats.

The UDS2100 also features robust diagnostic capabilities, offering real-time monitoring and logging of connections. This allows users to troubleshoot issues efficiently and maintain optimal performance of their connected devices. Moreover, the device supports multiple networking protocols, including DHCP and static IP addressing, providing further flexibility in network management.

With its compact design and robust enclosure, the UDS2100 can be easily integrated into existing systems without requiring significant modifications. Its reliability and performance make it suitable for various applications, including manufacturing, telecommunications, and medical devices. Overall, the Lantronix UDS2100 stands out as a reliable solution for businesses looking to modernize their infrastructure while maintaining compatibility with legacy equipment.