Lantronix UDS2100 manual Next Step, To configure the unit using a Telnet session

Page 19

 

 

 

 

 

3: Getting Started

 

 

 

 

 

 

 

 

 

 

Setting

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gateway

Displays the UDS2100’s current gateway. To change the

 

 

 

 

 

gateway, see Assigning an IP Address on page 16.

 

 

 

 

 

 

 

Number of Ports

 

Displays 2, the number of ports on the UDS2100.

 

 

 

 

 

 

 

TCP Keepalive

 

Displays the UDS2100’s TCP keepalive value. The value is

 

 

 

 

 

in the range 1-65s, and the default setting is 45.

 

 

 

 

 

 

 

Supports Configurable

 

Displays False.

 

 

Pins

 

 

 

 

 

 

 

 

 

 

 

Supports Email Triggers

 

Displays False.

 

 

 

 

 

 

 

Supports AES Data

 

Displays False.

 

 

Stream

 

 

 

 

 

 

 

 

 

 

 

Supports 485

 

Displays True. The UDS2100 supports the RS-485

 

 

 

 

 

protocol.

 

 

 

 

 

 

 

Supports 920K Baudrate

 

Displays True. The UDS2100 supports baud rates up to

 

 

 

 

 

920K.

 

 

 

 

 

 

 

Supports HTTP Server

 

Displays True. The UDS2100 supports HTTP server.

 

 

 

 

 

 

 

Supports HTTP Setup

 

Displays True. The UDS2100 supports HTTP setup.

 

 

 

 

 

 

 

Supports 230K Baud

 

Displays True. The UDS2100 supports a baud rate of

 

 

Rate

 

230K.

 

 

 

 

 

 

 

Supports GPIO

 

False

 

 

 

 

 

 

 

 

Next Step

You have the following options:

To configure the unit using a Web browser:

1.Click the Web Configuration tab.

2.Do one of the following:

To view the Web Manager in the current DeviceInstaller window, click the Go button.

To open the Web Manager in a web browser, click the External Browser button.

The Web Manager displays. A user and password dialog box displays.

3.By default, no user and password are configured, so just press OK.

4.Continue with 4: Configuration Using Web Manager.

Note: Alternatively, to open Web Manager, open your web browser and enter the IP address of the unit.

To configure the unit using a Telnet session:

1.Click the Telnet Configuration tab. The Setup Mode window displays.

2.Press Enter within 5 seconds.

UDS2100 User Guide

19

Image 19
Contents UDS2100 User Guide Date Rev Comments Copyright & TrademarkContacts RevisionsContents Setup Mode Server Configuration Warranty Tables FiguresChapter Description Using This GuidePurpose and Audience Chapter SummaryDocument Additional DocumentationApplications IntroductionApplication Examples Introduction Configuration Methods Additional FeaturesProtocol Support Sample Hardware Address 00-20-4A-14-01-18 or 00204A140118 Product Information LabelGetting Started Package ContentsTo install the unit Installing the UDSIP Address Subnet Mask Gateway Required InformationHardware Address IP AddressSelect Assign a specific IP address and click Next Assigning the IP Address DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressAdding the Unit to the Manage List Accessing the UDS2100 Using DeviceInstallerViewing the Current Configuration To view the units current settingsGetting Started SettingNext Step To configure the unit using a Telnet sessionPress Enter within 5 seconds Assigning the IP Address Serial Port Login Accessing UDS2100 Using DeviceInstaller Configuration Using Web ManagerLantronix Web Manager Network ConfigurationTo assign an IP address automatically Automatic IP Address ConfigurationSelect Obtain IP address automatically To assign an IP address manually Static IP Address ConfigurationEthernet Configuration Select Use the following IP configurationAdvanced Server ConfigurationTo configure the UDS2100’s device server settings Server ConfigurationTo configure the host list Host List ConfigurationHost Information Channel 1 and Channel 2 ConfigurationSerial Settings Retry SettingsChannel Port SettingsFlush Input Buffer Serial to Network Pack ControlTo configure a channel’s TCP settings Connection Settings TCPFlush Output Buffer Network to Serial Connect Protocol Connect Mode Passive ConnectionConnect Mode Active Connection Endpoint ConfigurationCommon Options Disconnect ModeTo configure a channel’s UDP settings Connection Settings UDPDatagram Mode Apply Factory Defaults Apply SettingsAccessing Setup Mode Configuration via Telnet or Serial Port Setup ModeTelnet Connection To establish a Telnet connection Serial Port ConnectionTo exit setup mode Exiting Setup ModeSet Gateway IP Address Setup Mode Server ConfigurationServer Configuration Option IP AddressNetwork Class Host Bits Netmask Change Telnet Configuration PasswordNetmask Number of Bits for Host Part Dhcp NameSetup Mode Server Configuration Channel 1 Option Setup Mode Channel ConfigurationBaudrate Flow Interface ModeMode Option Common I/F Mode Setting BinaryPort Numbers Reserved for Connect ModePort Number Flow Control Option HexConnect Mode Option Response Incoming ConnectionActive Startup Manual Connection Address Example Datagram Type To enable the hostlistModem Mode No Carrier MessageMeaningModem Mode Function Command Send the Escape Sequence +++ in Modem ModeAuto Increment Source Port DisConnMode Disconnect Mode OptionRemote IP Address Remote PortPack Control Flush Mode Buffer FlushingOption Packing IntervalTrailing Characters Send CharactersTelnet Terminal Type DisConnTime Inactivity TimeoutChannel Port Password Send CharactersExpert Settings Option Setup Mode Advanced SettingsTCP Keepalive time in seconds Http Port Number ARP Cache timeout in secondsDisable Monitor Mode at bootup Enable alternate MACSnmp Community Name Security Settings OptionDisable Snmp Disable Telnet SetupDisable Web Setup Disable Tftp Firmware UpdateDisable Port 77FE Hex Disable Web ServerSecurity Settings Defaults Default Settings OptionChannel 1 and Channel 2 Configuration Defaults Expert Settings DefaultsSetup Mode Advanced Settings ROM File Firmware UpgradesUsing Tftp Graphical User Interface Obtaining Firmware Reloading FirmwareTo recover firmware Using Tftp Command Line InterfaceFirmware Upgrades Monitor Mode Commands Monitor ModeEntering Monitor Mode Using the Serial Port Entering Monitor Mode Using the Network PortResponse Meaning Command Command Name FunctionLEDs Troubleshooting and Contact InformationLEDs Meaning Diagnostic, Power, and Serial Port LEDs UDS2100 LEDsProblem/Message Reason Solution Problems and Error MessagesProblem/Message Reason Solution Technical Support Europe, Middle East, and Africa Technical SupportConnections and Pinouts Serial Connector PinoutsUDS2100 Serial Ports Network Port Reset ButtonEthernet Connector Pinouts Power Plug To reset the unit to factory defaultsCategory Description Technical SpecificationsCategory Description Transient over voltages AutoIP Alternative Ways to Assign an IP AddressTo assign a temporary IP address ARP and TelnetConversion Table Converting Binary to HexadecimalDecimal Binary Hex Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index

UDS2100 specifications

The Lantronix UDS2100 is a versatile device server designed to facilitate connections between serial devices and Ethernet networks. This innovative product acts as a bridge, allowing for seamless communication between legacy serial devices and modern IP-based systems. Its importance has grown, particularly in industries that still rely on serial technology but seek to integrate with contemporary IT infrastructures.

One of the main features of the UDS2100 is its ability to connect up to two serial devices simultaneously. This dual-port capability makes it an efficient solution for environments where multiple devices need to be networked without additional complexity. By enabling these connections, the UDS2100 allows for remote control and monitoring of various equipment, leading to increased operational efficiency.

The device supports a variety of communication protocols, including TCP/IP, UDP, and HTTP, ensuring compatibility with a broad range of applications. This flexibility is complemented by the UDS2100’s support for both standard and custom baud rates, making it adaptable to various serial device configurations. Users can configure the device via a web-based interface, simplifying the setup process and enhancing user experience.

In terms of security, the Lantronix UDS2100 is equipped with numerous features to protect data transmission over the network. These include support for Secure Sockets Layer (SSL) and Transport Layer Security (TLS), which encrypt the data being transmitted, ensuring that sensitive information remains protected from potential threats.

The UDS2100 also features robust diagnostic capabilities, offering real-time monitoring and logging of connections. This allows users to troubleshoot issues efficiently and maintain optimal performance of their connected devices. Moreover, the device supports multiple networking protocols, including DHCP and static IP addressing, providing further flexibility in network management.

With its compact design and robust enclosure, the UDS2100 can be easily integrated into existing systems without requiring significant modifications. Its reliability and performance make it suitable for various applications, including manufacturing, telecommunications, and medical devices. Overall, the Lantronix UDS2100 stands out as a reliable solution for businesses looking to modernize their infrastructure while maintaining compatibility with legacy equipment.