Lantronix UDS2100 manual Static IP Address Configuration, Ethernet Configuration

Page 24

4: Configuration Using Web Manager

4.When you are finished, click the OK button.

5.On the main menu, click Apply Settings.

Static IP Address Configuration

You can manually assign an IP address to the unit and enter related network settings.

To assign an IP address manually:

1.On the main menu, click Network.

2.Select Use the following IP configuration.

3.Enter the following (as necessary):

IP Address

If DHCP is not used to assign IP addresses, enter it

 

manually in decimal-dot notation. The IP address must be

 

set to a unique value in the network.

 

 

Subnet Mask

A subnet mask defines the number of bits taken from the

 

IP address that are assigned for the host part.

 

 

Default Gateway

The gateway address, or router, allows communication to

 

other LAN segments. The gateway address should be the

 

IP address of the router connected to the same LAN

 

segment as the unit. The gateway address must be within

 

the local network.

 

 

4.When you are finished, click the OK button.

5.On the main menu, click Apply Settings.

Ethernet Configuration

You must specify the speed and direction of data transmission.

To specify how data will be transmitted:

1.On the main menu, click Network.

2.Enter the following (as necessary):

Auto Negotiate

With this option, the Ethernet port auto-negotiates the speed and duplex with the hardware endpoint to which it is connected. This is the default.

If this option is not selected, complete the fields that become available:

Speed: The speed of data transmission. The default setting is 100 Mbps.

Duplex: The direction of data transmission. The default setting is Full.

3.When you are finished, click the OK button.

4.On the main menu, click Apply Settings.

UDS2100 User Guide

24

Image 24
Contents UDS2100 User Guide Copyright & Trademark ContactsRevisions Date Rev CommentsContents Setup Mode Server Configuration Warranty Figures TablesUsing This Guide Purpose and AudienceChapter Summary Chapter DescriptionAdditional Documentation DocumentIntroduction ApplicationsApplication Examples Introduction Additional Features Configuration MethodsProtocol Support Product Information Label Sample Hardware Address 00-20-4A-14-01-18 or 00204A140118Package Contents Getting StartedInstalling the UDS To install the unitRequired Information Hardware AddressIP Address IP Address Subnet Mask GatewayAssigning the IP Address DeviceInstaller Installing DeviceInstallerAssigning an IP Address Select Assign a specific IP address and click NextAccessing the UDS2100 Using DeviceInstaller Viewing the Current ConfigurationTo view the units current settings Adding the Unit to the Manage ListSetting Getting StartedTo configure the unit using a Telnet session Next StepPress Enter within 5 seconds Assigning the IP Address Serial Port Login Configuration Using Web Manager Accessing UDS2100 Using DeviceInstallerNetwork Configuration Lantronix Web ManagerAutomatic IP Address Configuration To assign an IP address automaticallySelect Obtain IP address automatically Static IP Address Configuration Ethernet ConfigurationSelect Use the following IP configuration To assign an IP address manuallyServer Configuration To configure the UDS2100’s device server settingsServer Configuration AdvancedHost List Configuration To configure the host listChannel 1 and Channel 2 Configuration Serial SettingsRetry Settings Host InformationPort Settings ChannelPack Control Flush Input Buffer Serial to NetworkConnection Settings TCP To configure a channel’s TCP settingsFlush Output Buffer Network to Serial Connect Mode Passive Connection Connect Mode Active ConnectionEndpoint Configuration Connect ProtocolDisconnect Mode Common OptionsConnection Settings UDP To configure a channel’s UDP settingsDatagram Mode Apply Settings Apply Factory DefaultsConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection Serial Port Connection To establish a Telnet connectionExiting Setup Mode To exit setup modeSetup Mode Server Configuration Server Configuration OptionIP Address Set Gateway IP AddressChange Telnet Configuration Password Netmask Number of Bits for Host PartDhcp Name Network Class Host Bits NetmaskSetup Mode Server Configuration Setup Mode Channel Configuration Channel 1 OptionBaudrate Interface Mode Mode OptionCommon I/F Mode Setting Binary FlowConnect Mode Port NumberFlow Control Option Hex Port Numbers Reserved forConnect Mode Option Incoming Connection ResponseActive Startup Manual Connection Address Example To enable the hostlist Datagram TypeModem Mode MessageMeaning No CarrierSend the Escape Sequence +++ in Modem Mode Modem Mode Function CommandAuto Increment Source Port Disconnect Mode Option Remote IP AddressRemote Port DisConnModeFlush Mode Buffer Flushing Pack ControlPacking Interval Trailing CharactersSend Characters OptionDisConnTime Inactivity Timeout Channel Port PasswordSend Characters Telnet Terminal TypeSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds ARP Cache timeout in seconds Disable Monitor Mode at bootupEnable alternate MAC Http Port NumberSecurity Settings Option Disable SnmpDisable Telnet Setup Snmp Community NameDisable Tftp Firmware Update Disable Port 77FE HexDisable Web Server Disable Web SetupDefault Settings Option Channel 1 and Channel 2 Configuration DefaultsExpert Settings Defaults Security Settings DefaultsSetup Mode Advanced Settings Firmware Upgrades Using Tftp Graphical User InterfaceObtaining Firmware Reloading Firmware ROM FileUsing Tftp Command Line Interface To recover firmwareFirmware Upgrades Monitor Mode Entering Monitor Mode Using the Serial PortEntering Monitor Mode Using the Network Port Monitor Mode CommandsCommand Command Name Function Response MeaningTroubleshooting and Contact Information LEDsDiagnostic, Power, and Serial Port LEDs UDS2100 LEDs LEDs MeaningProblems and Error Messages Problem/Message Reason SolutionProblem/Message Reason Solution Technical Support Technical Support Europe, Middle East, and AfricaSerial Connector Pinouts Connections and PinoutsUDS2100 Serial Ports Reset Button Ethernet Connector Pinouts Power PlugTo reset the unit to factory defaults Network PortTechnical Specifications Category DescriptionCategory Description Transient over voltages Alternative Ways to Assign an IP Address AutoIPARP and Telnet To assign a temporary IP addressConverting Binary to Hexadecimal Conversion TableDecimal Binary Hex Scientific Calculator Warranty Compliance and Disclaimer Disclaimer and Supplementary Information Index

UDS2100 specifications

The Lantronix UDS2100 is a versatile device server designed to facilitate connections between serial devices and Ethernet networks. This innovative product acts as a bridge, allowing for seamless communication between legacy serial devices and modern IP-based systems. Its importance has grown, particularly in industries that still rely on serial technology but seek to integrate with contemporary IT infrastructures.

One of the main features of the UDS2100 is its ability to connect up to two serial devices simultaneously. This dual-port capability makes it an efficient solution for environments where multiple devices need to be networked without additional complexity. By enabling these connections, the UDS2100 allows for remote control and monitoring of various equipment, leading to increased operational efficiency.

The device supports a variety of communication protocols, including TCP/IP, UDP, and HTTP, ensuring compatibility with a broad range of applications. This flexibility is complemented by the UDS2100’s support for both standard and custom baud rates, making it adaptable to various serial device configurations. Users can configure the device via a web-based interface, simplifying the setup process and enhancing user experience.

In terms of security, the Lantronix UDS2100 is equipped with numerous features to protect data transmission over the network. These include support for Secure Sockets Layer (SSL) and Transport Layer Security (TLS), which encrypt the data being transmitted, ensuring that sensitive information remains protected from potential threats.

The UDS2100 also features robust diagnostic capabilities, offering real-time monitoring and logging of connections. This allows users to troubleshoot issues efficiently and maintain optimal performance of their connected devices. Moreover, the device supports multiple networking protocols, including DHCP and static IP addressing, providing further flexibility in network management.

With its compact design and robust enclosure, the UDS2100 can be easily integrated into existing systems without requiring significant modifications. Its reliability and performance make it suitable for various applications, including manufacturing, telecommunications, and medical devices. Overall, the Lantronix UDS2100 stands out as a reliable solution for businesses looking to modernize their infrastructure while maintaining compatibility with legacy equipment.