Lantronix 900-588 manual Show IP addr after Ring, Auto Increment Source Port, Remote IP Address

Page 51

8: Setup Mode: Channel Configuration

Show IP addr after 'RING'

Show IP addr after ‘RING’ (Y) ?

Disable or enable the Micro125's ability to show the IP address after RING in Modem Mode. The default is Y (Yes), to show the IP address.

Auto Increment Source Port

Auto increment source port (N) ? _

Y (Yes) auto increment the source port. The Micro125 increments the port number used with each new connection.

Remote IP Address

This is the destination IP address used with an outgoing connection.

Remote IP Address : (000) (000) (000) (000)_

Note: This option does not display when Hostlist is enabled from the ConnectMode prompt (see Connect Mode on page 44 for more information).

Remote Port

You must set the remote TCP port number for the unit to make outgoing connections. This parameter defines the port number on the target host to which a connection is attempted.

Remote Port (00) ? _

To connect an ASCII terminal to a host using the unit for login purposes, use the remote port number 23 (Internet standard port number for Telnet services).

Note: This option does not display when Hostlist is enabled from the ConnectMode prompt (see Connect Mode on page 44 for more information).

DisConnMode

This setting determines the conditions under which the unit will cause a network connection to terminate.

DisConnMode (00) ? _

Notes:

In DisConnMode (Disconnect Mode), Modem Control In drop either drops the connection or is ignored.

All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Micro125 User Guide

51

Image 51
Contents User Guide Date Rev Firmware Comments Lantronix Corporate HeadquartersTechnology Drive Irvine, CA 92618, USA Toll Free Phone Fax Technical Support Sales OfficesTable of Contents Configuration via Telnet or Serial Port Setup Mode Problems and Error Messages Technical Support Setup Mode Advanced SettingsList of Tables List of FiguresRemaining chapters in this guide include Using This GuidePurpose and Audience Chapter SummaryMicro125 Integration Guide DeviceInstaller Online HelpAdditional Documentation Document DescriptionIntroduction CapabilitiesApplications Hardware Address Configuration MethodsProtocol Support Addresses and Port NumbersPort Numbers IP Address10/100 Ethernet Physically Connecting the UnitGetting Started Required InformationGetting Started Assigning an IP Address Using DeviceInstallerInstalling DeviceInstaller To install DeviceInstallerTo view the units current settings Accessing the Micro125 Using DeviceInstallerViewing the Current Configuration DeviceInstaller provides a view of the units configurationHardware Address CommentsDevice Family TypeFirmware UpgradeableConfigurable Pins Setup Supports 230K BaudAccessing Web-Manager Using DeviceInstaller Configuration Using Web ManagerLantronix Web-Manager Web-Manager Login WindowSelect Obtain IP address automatically Network ConfigurationNetwork Mode Automatic IP Address ConfigurationTo assign an IP address manually Static IP Address ConfigurationSelect Use the following IP configuration Enter the following as necessaryAuto Negotiate Ethernet ConfigurationEthernet Settings Description To specify how data will be transmittedServer Configuration To configure the Micro125’s device server settingsServer Configuration Description Settings On the main menu, click Hostlist Host List ConfigurationTo configure the Micro125’s host list Advanced Settings DescriptionHost Information Channel 1 and Channel 2 ConfigurationRetry Settings Retry Settings DescriptionPort Settings Description Serial SettingsTo configure the channel’s serial settings Channel Setting DescriptionPack Control Settings Description With Passive Connect Flush Input Buffer Settings DescriptionFlush Output Buffer Description Settings With Active ConnectTo configure a channel’s TCP settings Connection Settings TCPAvailable fields, enter or modify the following information Connect Protocol Setting DescriptionPassive Connection Mode Description Settings Active Connection Mode Description SettingsEndpoint Configuration Description Settings Common Option Settings DescriptionDisconnect Mode Settings Description Check EOT Ctrl-D Connection Settings UDPTo configure a channel’s UDP settings Inactivity TimeoutApply Settings Datagram Mode Description SettingsConnection Protocol Description Applying Settings Apply DefaultsConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection Serial Port Connection To establish a Telnet connectionClick OK. The following information displays To exit setup mode, utilize one of the following two options Exiting Setup ModeIP Address Setup Mode Server ConfigurationServer Configuration Option This chapter explains how to configure the network settingsStandard IP Network Netmasks Set Gateway IP AddressNetmask Number of Bits for Host Part Set DNS Server IP AddressDhcp Name Change Telnet/Web-Manager PasswordSetup Mode Channel Configuration ChannelsBaudrate Common I/F Mode Setting Binary Hex Interface ModeFollowing table displays available I/F Mode options Mode OptionFlow Port NumberUse the following table to select flow control options Connect Mode Option Connect ModeEnter Connect Mode options in hexadecimal notation Connect Mode OptionsActive Startup ResponseC0.0.0.0/0 Manual Connection Address ExampleC121.2.4.5/1 C28.10/12Hostlist Option To enable the hostlistDatagram Type Description Modem ModeModem Mode Description Datagram TypeNetwork connection has been established Modem Mode MessagesFull Verbose Command was executed without error Message MeaningModem Mode Function Command Send the Escape Sequence +++ in Modem ModeRemote Port Show IP addr after RingAuto Increment Source Port Remote IP AddressDisconnect Mode Option 11. Disconnect Mode OptionsFlush Mode Buffer Flushing Pack ControlOption Send Characters DisConnTime Inactivity TimeoutPacking Interval Trailing CharactersChannel Port Password Send CharactersTelnet Terminal Type Device Details Settings Description Setup Mode Advanced SettingsExpert Settings Option Default settings are listed belowEnable Alternate MAC ARP Cache Timeout in SecondsDisable Monitor Mode at Bootup TCP Re-transmission TimeoutSelect 6 to configure security settings Security Settings OptionDisable Snmp Disable Telnet SetupDisable Web Setup Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Web ServerTo configure AES encryption on the Micro125 Enable Enhanced PasswordChannel Setting Default Configuration Default Settings OptionChannel 1 and Channel 2 Configuration Defaults Expert Settings DefaultsSecurity Setting Default Configuration Security Settings DefaultsTo download new firmware from a computer Firmware UpgradesUsing Tftp Graphical User Interface Obtaining Firmware Reloading FirmwareFirmware Upgrades Using Tftp Command Line InterfaceTo recover firmware Monitor Mode Commands Monitor ModeEntering Monitor Mode Using the Serial Port Entering Monitor Mode Using the Network PortS0, S1,...,Se, Sf Monitor Mode CommandsCommand Command Name Function G0, G1, ....,Ge, GfResponse Meaning Troubleshooting Problems and Error MessagesProblem/Message Reason Solution Caps Lock is not on TroubleshootingCorrectly to make a good socket Technical Support Europe, Middle East, and Africa Technical SupportTechnical Support US Phone 800 422-7044 US Only 949Decimal Binary Hex Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableScientific Calculator