Lantronix 900-588 manual DisConnTime Inactivity Timeout, Packing Interval, Trailing Characters

Page 54

8: Setup Mode: Channel Configuration

 

Option

 

 

7

 

 

6

 

 

5

 

 

4

 

 

3

 

 

2

 

 

1

 

 

0

 

 

Interval: 12ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 52ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 250ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 5sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trailing Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Byte Send Character Sequence

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Immediately After Send chars

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Packing Interval

Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is between successive network segments containing data. For alternate packing, the default interval is 12 ms.

Trailing Characters

In some applications, CRC, Checksum, or other trailing characters follow the end-of- sequence character; this option helps to adapt frame transmission to the frame boundary.

Send Characters

If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2- byte sequence; if this option is not enabled, the unit interprets them independently.

If Send Immediately After Characters is not set, any characters already in the serial buffer are included in the transmission after a "transmit" condition is found. If this option is set, the unit sends immediately after recognizing the transmit condition (sendchar or timeout).

Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.

DisConnTime (Inactivity Timeout)

Use this parameter to set an inactivity timeout. The unit drops the the TCP connection to port 10001/10002* if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds.

Note*: The default port number for Port 1 is 10001 and 10002 for Port 2. However, port numbers may be set to a different value.

Micro125 User Guide

54

Image 54
Contents User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersTechnology Drive Irvine, CA 92618, USA Toll Free Phone Fax Date Rev Firmware CommentsTable of Contents Configuration via Telnet or Serial Port Setup Mode Setup Mode Advanced Settings Problems and Error Messages Technical SupportList of Figures List of TablesChapter Summary Using This GuidePurpose and Audience Remaining chapters in this guide includeDocument Description DeviceInstaller Online HelpAdditional Documentation Micro125 Integration GuideIntroduction CapabilitiesApplications Addresses and Port Numbers Configuration MethodsProtocol Support Hardware AddressIP Address Port NumbersRequired Information Physically Connecting the UnitGetting Started 10/100 EthernetGetting Started To install DeviceInstaller Using DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressDeviceInstaller provides a view of the units configuration Accessing the Micro125 Using DeviceInstallerViewing the Current Configuration To view the units current settingsType CommentsDevice Family Hardware AddressSetup Supports 230K Baud UpgradeableConfigurable Pins FirmwareConfiguration Using Web Manager Accessing Web-Manager Using DeviceInstallerWeb-Manager Login Window Lantronix Web-ManagerAutomatic IP Address Configuration Network ConfigurationNetwork Mode Select Obtain IP address automaticallyEnter the following as necessary Static IP Address ConfigurationSelect Use the following IP configuration To assign an IP address manuallyTo specify how data will be transmitted Ethernet ConfigurationEthernet Settings Description Auto NegotiateServer Configuration To configure the Micro125’s device server settingsServer Configuration Description Settings Advanced Settings Description Host List ConfigurationTo configure the Micro125’s host list On the main menu, click HostlistRetry Settings Description Channel 1 and Channel 2 ConfigurationRetry Settings Host InformationChannel Setting Description Serial SettingsTo configure the channel’s serial settings Port Settings DescriptionPack Control Settings Description With Active Connect Flush Input Buffer Settings DescriptionFlush Output Buffer Description Settings With Passive ConnectConnection Settings TCP To configure a channel’s TCP settingsActive Connection Mode Description Settings Connect Protocol Setting DescriptionPassive Connection Mode Description Settings Available fields, enter or modify the following informationEndpoint Configuration Description Settings Common Option Settings DescriptionDisconnect Mode Settings Description Inactivity Timeout Connection Settings UDPTo configure a channel’s UDP settings Check EOT Ctrl-DApply Settings Datagram Mode Description SettingsConnection Protocol Description Apply Defaults Applying SettingsConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection Serial Port Connection To establish a Telnet connectionClick OK. The following information displays Exiting Setup Mode To exit setup mode, utilize one of the following two optionsThis chapter explains how to configure the network settings Setup Mode Server ConfigurationServer Configuration Option IP AddressSet DNS Server IP Address Set Gateway IP AddressNetmask Number of Bits for Host Part Standard IP Network NetmasksChange Telnet/Web-Manager Password Dhcp NameSetup Mode Channel Configuration ChannelsBaudrate Mode Option Interface ModeFollowing table displays available I/F Mode options Common I/F Mode Setting Binary HexFlow Port NumberUse the following table to select flow control options Connect Mode Options Connect ModeEnter Connect Mode options in hexadecimal notation Connect Mode OptionResponse Active StartupC28.10/12 Manual Connection Address ExampleC121.2.4.5/1 C0.0.0.0/0To enable the hostlist Hostlist OptionDatagram Type Modem ModeModem Mode Description Datagram Type DescriptionMessage Meaning Modem Mode MessagesFull Verbose Command was executed without error Network connection has been establishedSend the Escape Sequence +++ in Modem Mode Modem Mode Function CommandRemote IP Address Show IP addr after RingAuto Increment Source Port Remote Port11. Disconnect Mode Options Disconnect Mode OptionFlush Mode Buffer Flushing Pack ControlOption Trailing Characters DisConnTime Inactivity TimeoutPacking Interval Send CharactersChannel Port Password Send CharactersTelnet Terminal Type Default settings are listed below Setup Mode Advanced SettingsExpert Settings Option Device Details Settings DescriptionTCP Re-transmission Timeout ARP Cache Timeout in SecondsDisable Monitor Mode at Bootup Enable Alternate MACDisable Telnet Setup Security Settings OptionDisable Snmp Select 6 to configure security settingsDisable Web Server Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Web SetupEnable Enhanced Password To configure AES encryption on the Micro125Expert Settings Defaults Default Settings OptionChannel 1 and Channel 2 Configuration Defaults Channel Setting Default ConfigurationSecurity Settings Defaults Security Setting Default ConfigurationObtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface To download new firmware from a computerUsing Tftp Command Line Interface Firmware UpgradesTo recover firmware Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsG0, G1, ....,Ge, Gf Monitor Mode CommandsCommand Command Name Function S0, S1,...,Se, SfResponse Meaning Troubleshooting Problems and Error MessagesProblem/Message Reason Solution Troubleshooting Caps Lock is not onCorrectly to make a good socket Phone 800 422-7044 US Only 949 Technical SupportTechnical Support US Technical Support Europe, Middle East, and AfricaConversion Table Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Decimal Binary HexScientific Calculator