Device Details

 

Description

 

 

Settings

 

 

 

 

 

 

 

 

 

Comments

 

Configurable field. Information about the Micro125.

 

 

 

Double-click the field, type in the value, and press Enter to complete. This

 

 

 

description or comment is not visible on other PCs or laptops using

 

 

 

DeviceInstaller.

 

 

 

 

 

Device Family

 

Non-configurable field. Displays the Micro125’s device family as Micro125.

 

 

 

 

 

Type

 

Non-configurable field. Displays the device type as Micro125.

 

 

 

 

 

ID

 

Non-configurable field. Displays the Micro125’s ID embedded within the

 

 

 

box.

 

Hardware Address

 

Non-configurable field. Displays the Micro125’s hardware (or MAC)

 

 

 

address.

 

Firmware Version

 

Non-configurable field. Displays the firmware currently installed on the

 

 

 

Micro.

 

Extended Firmware

 

Non-configurable field. Displays the full version nomenclature of the

 

Version

 

firmware.

 

Online Status

 

Non-configurable field. Displays the Micro125’s status as online, offline,

 

 

 

unreachable (the Micro125 is on a different subnet), or busy (the Micro125

 

 

 

is currently performing a task).

 

 

 

 

 

IP Address

 

Non-configurable field. Displays the Micro125’s current IP address. To

 

 

 

change the IP address, click Assign IP on the DeviceInstaller menu bar.

 

IP Address was

 

Displays “Dynamically” if the device automatically received an IP address

 

Obtained

 

(e.g., from DHCP). Displays “Statically” if the IP address was configured

 

 

 

manually. If the IP address was assigned dynamically, the following fields

 

 

 

appear:

 

 

 

Obtain via DHCP with value of True or False.

 

 

 

Obtain via BOOTP with value of True or False.

 

 

 

Obtain via RARP with value of True or False

 

 

 

Obtain via Auto IP with value of True or False

 

Subnet Mask

 

Non-configurable field. Displays the Micro125’s current subnet mask.

 

 

 

 

 

Gateway

 

Non-configurable field. Displays the Micro125’s current gateway.

 

 

 

 

 

Number of COB

 

Non-configurable field. Displays the number of COB partitions supported.

 

partitions supported

 

 

 

 

 

Number of Serial

 

Non-configurable field. Displays the number of ports on the Micro125.

 

Ports

 

 

 

 

 

TCP Keepalive

 

Non-configurable field. Displays 1-65s, the Micro125’s TCP keepalive

 

 

 

value. The default setting is 45.

 

 

 

 

 

Telnet Supported

 

Non-configurable field. Indicates whether Telnet is enabled on this

 

 

 

Micro125.

 

 

 

 

 

Telnet Port

 

Non-configurable field. Displays the Micro125’s port for Telnet sessions.

 

 

 

 

 

Web Port

 

Non-configurable field. Displays the Micro125’s port for Web-Manager

 

 

 

configuration.

 

 

 

 

 

Maximum Baud Rate

 

Non-configurable field. Displays the Micro125’s maximum baud rate.

 

Supported

 

Note: the Micro125 may not currently be running at this rate.

 

 

 

 

 

 

Micro125 User Guide

16

Image 16
Contents User Guide Lantronix Corporate Headquarters Technology Drive Irvine, CA 92618, USA Toll Free Phone FaxTechnical Support Sales Offices Date Rev Firmware CommentsTable of Contents Configuration via Telnet or Serial Port Setup Mode Setup Mode Advanced Settings Problems and Error Messages Technical SupportList of Figures List of TablesUsing This Guide Purpose and AudienceChapter Summary Remaining chapters in this guide includeDeviceInstaller Online Help Additional DocumentationDocument Description Micro125 Integration GuideCapabilities IntroductionApplications Configuration Methods Protocol SupportAddresses and Port Numbers Hardware AddressIP Address Port NumbersPhysically Connecting the Unit Getting StartedRequired Information 10/100 EthernetGetting Started Using DeviceInstaller Installing DeviceInstallerTo install DeviceInstaller Assigning an IP AddressAccessing the Micro125 Using DeviceInstaller Viewing the Current ConfigurationDeviceInstaller provides a view of the units configuration To view the units current settingsComments Device FamilyType Hardware AddressUpgradeable Configurable PinsSetup Supports 230K Baud FirmwareConfiguration Using Web Manager Accessing Web-Manager Using DeviceInstallerWeb-Manager Login Window Lantronix Web-ManagerNetwork Configuration Network ModeAutomatic IP Address Configuration Select Obtain IP address automaticallyStatic IP Address Configuration Select Use the following IP configurationEnter the following as necessary To assign an IP address manuallyEthernet Configuration Ethernet Settings DescriptionTo specify how data will be transmitted Auto NegotiateTo configure the Micro125’s device server settings Server ConfigurationServer Configuration Description Settings Host List Configuration To configure the Micro125’s host listAdvanced Settings Description On the main menu, click HostlistChannel 1 and Channel 2 Configuration Retry SettingsRetry Settings Description Host InformationSerial Settings To configure the channel’s serial settingsChannel Setting Description Port Settings DescriptionPack Control Settings Description Flush Input Buffer Settings Description Flush Output Buffer Description SettingsWith Active Connect With Passive ConnectConnection Settings TCP To configure a channel’s TCP settingsConnect Protocol Setting Description Passive Connection Mode Description SettingsActive Connection Mode Description Settings Available fields, enter or modify the following informationCommon Option Settings Description Endpoint Configuration Description SettingsDisconnect Mode Settings Description Connection Settings UDP To configure a channel’s UDP settingsInactivity Timeout Check EOT Ctrl-DDatagram Mode Description Settings Apply SettingsConnection Protocol Description Apply Defaults Applying SettingsAccessing Setup Mode Configuration via Telnet or Serial Port Setup ModeTelnet Connection To establish a Telnet connection Serial Port ConnectionClick OK. The following information displays Exiting Setup Mode To exit setup mode, utilize one of the following two optionsSetup Mode Server Configuration Server Configuration OptionThis chapter explains how to configure the network settings IP AddressSet Gateway IP Address Netmask Number of Bits for Host PartSet DNS Server IP Address Standard IP Network NetmasksChange Telnet/Web-Manager Password Dhcp NameChannels Setup Mode Channel ConfigurationBaudrate Interface Mode Following table displays available I/F Mode optionsMode Option Common I/F Mode Setting Binary HexPort Number FlowUse the following table to select flow control options Connect Mode Enter Connect Mode options in hexadecimal notationConnect Mode Options Connect Mode OptionResponse Active StartupManual Connection Address Example C121.2.4.5/1C28.10/12 C0.0.0.0/0To enable the hostlist Hostlist OptionModem Mode Modem Mode DescriptionDatagram Type Datagram Type DescriptionModem Mode Messages Full Verbose Command was executed without errorMessage Meaning Network connection has been establishedSend the Escape Sequence +++ in Modem Mode Modem Mode Function CommandShow IP addr after Ring Auto Increment Source PortRemote IP Address Remote Port11. Disconnect Mode Options Disconnect Mode OptionPack Control Flush Mode Buffer FlushingOption DisConnTime Inactivity Timeout Packing IntervalTrailing Characters Send CharactersSend Characters Channel Port PasswordTelnet Terminal Type Setup Mode Advanced Settings Expert Settings OptionDefault settings are listed below Device Details Settings DescriptionARP Cache Timeout in Seconds Disable Monitor Mode at BootupTCP Re-transmission Timeout Enable Alternate MACSecurity Settings Option Disable SnmpDisable Telnet Setup Select 6 to configure security settingsDisable Tftp Firmware Upgrade Disable Port 77FE HexDisable Web Server Disable Web SetupEnable Enhanced Password To configure AES encryption on the Micro125Default Settings Option Channel 1 and Channel 2 Configuration DefaultsExpert Settings Defaults Channel Setting Default ConfigurationSecurity Settings Defaults Security Setting Default ConfigurationFirmware Upgrades Using Tftp Graphical User InterfaceObtaining Firmware Reloading Firmware To download new firmware from a computerUsing Tftp Command Line Interface Firmware UpgradesTo recover firmware Monitor Mode Entering Monitor Mode Using the Serial PortEntering Monitor Mode Using the Network Port Monitor Mode CommandsMonitor Mode Commands Command Command Name FunctionG0, G1, ....,Ge, Gf S0, S1,...,Se, SfResponse Meaning Problems and Error Messages TroubleshootingProblem/Message Reason Solution Troubleshooting Caps Lock is not onCorrectly to make a good socket Technical Support Technical Support USPhone 800 422-7044 US Only 949 Technical Support Europe, Middle East, and AfricaBinary to Hexadecimal Conversions Converting Binary to HexadecimalConversion Table Decimal Binary HexScientific Calculator