Lantronix 900-588 manual Apply Settings, Connection Protocol Description

Page 33

 

 

 

 

5: Configuration Using Web Manager

Connect Protocol

 

 

 

 

 

 

 

 

 

 

Connection Protocol

 

Description

 

 

 

 

 

 

 

Protocol

 

Select UDP from the drop-down menu.

 

 

 

 

 

Datagram Mode

 

 

 

 

 

 

 

 

 

 

Datagram Mode

 

Description

 

 

Settings

 

 

 

 

 

 

 

 

 

 

Datagram Type

 

Configures the remote IP or network broadcast address and the

 

 

 

 

remote port. Enter 01 for directed or broadcast UDP. The default

 

 

 

 

setting is 00.

 

 

Accept Incoming

 

Select Yes to accept incoming UDP datagrams.

 

 

 

 

 

Endpoint Configuration

 

 

 

 

 

 

 

 

 

 

Endpoint Configuration

 

Description

 

 

Settings

 

 

 

 

 

 

 

 

 

 

 

Local Port

 

Enter the local port number.

 

 

 

 

 

 

 

Remote Port

 

Enter the port number of the remote device.

 

 

 

 

 

 

 

Remote Host

 

Enter the IP address of the remote device.

 

 

 

 

 

 

 

Use Broadcast

 

Select to broadcast the UDP datagram. The default is not to

 

 

 

 

broadcast.

 

 

 

 

Note: Datagrams are sent as subnet-directed broadcasts.

 

 

 

 

 

 

 

Device Address Table

 

The table is enabled when Datagram Type is set to FD. Enter values

 

 

 

 

between 1 and 255 to identify units on the local network of device

 

 

 

 

servers.

 

 

 

 

Note: Lantronix Tech Support supports Datagram type 01. Datagram

 

 

 

 

Type FD is for OEM use.

3.When you are finished, click the OK button.

4.On the main menu, click Apply Settings.

Apply Settings

1.To save and apply the configuration changes to the device server, click the Apply Settings button.

Note: Clicking OK on each page does not change the configuration on the device. Clicking the OK button tells the MatchPort what changes to use; the Apply Settings makes the changes permanent and reboots the Micro125.

Micro125 User Guide

33

Image 33
Contents User Guide Technology Drive Irvine, CA 92618, USA Toll Free Phone Fax Lantronix Corporate HeadquartersTechnical Support Sales Offices Date Rev Firmware CommentsTable of Contents Configuration via Telnet or Serial Port Setup Mode Problems and Error Messages Technical Support Setup Mode Advanced SettingsList of Tables List of FiguresPurpose and Audience Using This GuideChapter Summary Remaining chapters in this guide includeAdditional Documentation DeviceInstaller Online HelpDocument Description Micro125 Integration GuideIntroduction CapabilitiesApplications Protocol Support Configuration MethodsAddresses and Port Numbers Hardware AddressPort Numbers IP AddressGetting Started Physically Connecting the UnitRequired Information 10/100 EthernetGetting Started Installing DeviceInstaller Using DeviceInstallerTo install DeviceInstaller Assigning an IP AddressViewing the Current Configuration Accessing the Micro125 Using DeviceInstallerDeviceInstaller provides a view of the units configuration To view the units current settingsDevice Family CommentsType Hardware AddressConfigurable Pins UpgradeableSetup Supports 230K Baud FirmwareAccessing Web-Manager Using DeviceInstaller Configuration Using Web ManagerLantronix Web-Manager Web-Manager Login WindowNetwork Mode Network ConfigurationAutomatic IP Address Configuration Select Obtain IP address automaticallySelect Use the following IP configuration Static IP Address ConfigurationEnter the following as necessary To assign an IP address manuallyEthernet Settings Description Ethernet ConfigurationTo specify how data will be transmitted Auto NegotiateServer Configuration To configure the Micro125’s device server settingsServer Configuration Description Settings To configure the Micro125’s host list Host List ConfigurationAdvanced Settings Description On the main menu, click HostlistRetry Settings Channel 1 and Channel 2 ConfigurationRetry Settings Description Host InformationTo configure the channel’s serial settings Serial SettingsChannel Setting Description Port Settings DescriptionPack Control Settings Description Flush Output Buffer Description Settings Flush Input Buffer Settings DescriptionWith Active Connect With Passive ConnectTo configure a channel’s TCP settings Connection Settings TCP Passive Connection Mode Description Settings Connect Protocol Setting Description Active Connection Mode Description Settings Available fields, enter or modify the following informationEndpoint Configuration Description Settings Common Option Settings DescriptionDisconnect Mode Settings Description To configure a channel’s UDP settings Connection Settings UDPInactivity Timeout Check EOT Ctrl-DApply Settings Datagram Mode Description SettingsConnection Protocol Description Applying Settings Apply DefaultsConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection Serial Port Connection To establish a Telnet connectionClick OK. The following information displays To exit setup mode, utilize one of the following two options Exiting Setup ModeServer Configuration Option Setup Mode Server ConfigurationThis chapter explains how to configure the network settings IP AddressNetmask Number of Bits for Host Part Set Gateway IP AddressSet DNS Server IP Address Standard IP Network NetmasksDhcp Name Change Telnet/Web-Manager PasswordSetup Mode Channel Configuration ChannelsBaudrate Following table displays available I/F Mode options Interface ModeMode Option Common I/F Mode Setting Binary HexFlow Port NumberUse the following table to select flow control options Enter Connect Mode options in hexadecimal notation Connect ModeConnect Mode Options Connect Mode OptionActive Startup ResponseC121.2.4.5/1 Manual Connection Address ExampleC28.10/12 C0.0.0.0/0Hostlist Option To enable the hostlistModem Mode Description Modem ModeDatagram Type Datagram Type DescriptionFull Verbose Command was executed without error Modem Mode MessagesMessage Meaning Network connection has been establishedModem Mode Function Command Send the Escape Sequence +++ in Modem ModeAuto Increment Source Port Show IP addr after RingRemote IP Address Remote PortDisconnect Mode Option 11. Disconnect Mode OptionsFlush Mode Buffer Flushing Pack ControlOption Packing Interval DisConnTime Inactivity TimeoutTrailing Characters Send CharactersChannel Port Password Send CharactersTelnet Terminal Type Expert Settings Option Setup Mode Advanced SettingsDefault settings are listed below Device Details Settings DescriptionDisable Monitor Mode at Bootup ARP Cache Timeout in SecondsTCP Re-transmission Timeout Enable Alternate MACDisable Snmp Security Settings OptionDisable Telnet Setup Select 6 to configure security settingsDisable Port 77FE Hex Disable Tftp Firmware UpgradeDisable Web Server Disable Web SetupTo configure AES encryption on the Micro125 Enable Enhanced PasswordChannel 1 and Channel 2 Configuration Defaults Default Settings OptionExpert Settings Defaults Channel Setting Default ConfigurationSecurity Setting Default Configuration Security Settings DefaultsUsing Tftp Graphical User Interface Firmware UpgradesObtaining Firmware Reloading Firmware To download new firmware from a computerFirmware Upgrades Using Tftp Command Line InterfaceTo recover firmware Entering Monitor Mode Using the Serial Port Monitor ModeEntering Monitor Mode Using the Network Port Monitor Mode CommandsCommand Command Name Function Monitor Mode CommandsG0, G1, ....,Ge, Gf S0, S1,...,Se, SfResponse Meaning Troubleshooting Problems and Error MessagesProblem/Message Reason Solution Caps Lock is not on TroubleshootingCorrectly to make a good socket Technical Support US Technical SupportPhone 800 422-7044 US Only 949 Technical Support Europe, Middle East, and AfricaConverting Binary to Hexadecimal Binary to Hexadecimal ConversionsConversion Table Decimal Binary HexScientific Calculator