Juniper Networks 5000 manual Fan Led

Page 63

FAN LED

The following table describes the Fan LED on both the NetScreen-5200 and NetScreen-5400 chassis.

LED Color

Meaning of the LED

 

 

green

Fans are operating.

 

 

off

Power is off.

 

 

NetScreen-5000 Series

VII

Image 63
Contents NETSCREEN-5000 Series Copyright Notice Table of Contents Servicing the Device IX-I Table of Contents Guide Organization PrefaceJuniper Networks Netscreen Publications Command Line Interface CLI ConventionsOverview1 NetScreen-5200 NetScreen-5400NETSCREEN-5000 Series NetScreen-5200 Power Recommendations NetScreen-5400 Power RecommendationsPower Supplies AC Power Supply DC Power SupplyNETSCREEN-5000 Modules FAN Modules5000-M Management Module Management Modules5000-M2 Management Module 5000-8G SPM Secure Port Modules5000-2G24FE SPM 5000-8G2 SPM Part Number Description Distance Fiber Type 5000-2XGE SPMOverview User’s Guide Installing the Device Equipment Rack Installation Guidelines General Installation GuidelinesMounting the NETSCREEN-5000 Series NetScreen-5200 Front and Rear MountNetScreen-5400 Front Mount NetScreen-5200 Mid-MountInstalling and Wiring a DC Power Supply Installing and Connecting the AC Power Supply48V COMThumbscrew Power Establishing AN HA Connection Connecting the NETSCREEN-5000 Series to a Router or SwitchInstalling the Device User’s Guide Configuring the Device Transparent Mode Route ModeOperational Modes NETSCREEN-5000 Interfaces NetScreen-5200 InterfacesNetScreen-5400 Interfaces Configurable InterfacesEstablishing a Terminal Emulator Connection Performing Initial Connection and ConfigurationUpgrading the Firmware During the Boot Process Setting the IP Address of the Management Interface Changing Your Admin Name and PasswordSetting Port and Interface IP Addresses Viewing Current Interface SettingsSetting the IP Address for the Untrust Zone Interface Setting the IP Address for the Trust Zone InterfaceStarting a Console Session Using Telnet Configuring the Device for Telnet and Webui SessionsAllowing Outbound Traffic Establishing a GUI Management Session Starting a Console Session Using DialupHttp//10.100.2.183 Configuring the Chassis AlarmConfiguring Aggregate Interfaces Configuring Jumbo FramesFollowing CLI command unset admin device-reset Using CLI Commands to Reset the DevicePress the y key Following message appears Servicing the Device Removing and Reseating Modules Replacing a DC Power SupplyReplacing the FAN Module Replacing AN AC Power SupplyNetScreen-5200 Fan Module Remove the fan tray See NetScreen-5200 Fan Module on NetScreen-5200 Fan Tray FilterNetScreen-5400 Fan Module Replacing the Fan Module Remove the fan tray See NetScreen-5400 Fan Module on NetScreen-5400 Fan Tray FilterRemoving and Installing a MINI-GBIC Transceiver Connecting and Disconnecting Gigabit Ethernet CablesServicing the Device User’s Guide Specifications Environmental Electrical SpecificationNETSCREEN-5200 Attributes NETSCREEN-5400 AttributesEMI Certifications Safety CertificationsConnectors Nebs CertificationsAppendix a Specifications Port Descriptions and LED Status B MGT Module Port DescriptionsFollowing table details the ports on the 5000-8G2 SPM Module LED DescriptionsStatus LED States Interpreting Status LEDs for the Management ModulesInterpreting Ethernet Port Status LEDs for All Modules Interpreting Status LEDs for the Secure Port ModuleSingle SPM Installed Interpreting Power Supply LED Status for the NetScreen-5200Interpreting Power Supply LED Status for the NetScreen-5400 Power Supply LedsFAN LED Viii Index IX-II