Magnum 6KQE Managed Edge Switch Installation and User Guide | 02/09 |
4.4Power Budget Calculations for 6KQE Modules with Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget. To calculate the power budget of different fiber media installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss) Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125μm (M.m) is 2.8 dB/km, and the “Cable Loss” for 100/140
and the “Cable Loss” for 9/125
and the “Cable Loss” for 9/125
See http://www.garrettcom.com/techsupport/power_budget.pdf for more information on Power budget calculations
5.0Magnum 6KQE Managed Edge Switch Port Modules
This chapter describes each Port Module (PM), including appearance, functionality, and status displays.
5.16KQE Modules
An important feature of the Magnum 6KQE is the use of Port Modules for
flexible
Note: The 6KQE Port modules are not identical to the port modules used in other 6K products such as the 6K25e and 6K16V. For information about other 6K products, please see the applicable manual. For a list of 6KQE Port Modules, refer to Section 1.2
Each 6KQE Port Module (PM) is individually described in the following sections.
www . GarrettCom . com
28