Enterasys Networks A2H254-16 manual Regulatory Compliance Information

Page 4

Regulatory Compliance Information

Federal Communications Commission (FCC) Notice

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.

WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Industry Canada Notice

This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.

Class A ITE Notice

WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Clase A. Aviso de ITE

ADVERTENCIA: Este es un producto de Clase A. En un ambiente doméstico este producto puede causar interferencia de radio en cuyo caso puede ser requerido tomar medidas adecuadas.

Klasse A ITE Anmerkung

WARNHINWEIS: Dieses Produkt zählt zur Klasse A (Industriebereich). In Wohnbereichen kann es hierdurch zu Funkstörungen kommen, daher sollten angemessene Vorkehrungen zum Schutz getroffen werden.

Product Safety

This product complies with the following: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950, EN 60825, 21 CFR 1040.10.

Seguridad del Producto

El producto de Enterasys cumple con lo siguiente: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950, EN 60825, 21 CFR 1040.10.

Produktsicherheit

Dieses Produkt entspricht den folgenden Richtlinien: UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950, IEC 60950, EN 60825, 21 CFR 1040.10.

ii

Image 4
Contents SecureStack A2 Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Safety Information Class 1 Laser Transceivers Declaration of Conformity Enterasys Networks, Inc Firmware License Agreement Vii Viii Contents Troubleshooting Figures Xii About This Guide Who Should Use This GuideHow to Use This Guide Related DocumentsConventions Used in This Guide Following conventions are used in this guideConventions Used in This Guide Xvi About This Guide Introduction OverviewA2H254-16 Redundant Power Supply Capability Stack ConnectionsConnectivity Description of Mini-GBICsLanview Diagnostic LEDs Switch Configuration Using WebViewSwitch Configuration Using CLI Commands ManagementGetting Help Network Requirements 10BASE-TX Twisted Pair Network1000BASE-T Twisted Pair Gigabit Ethernet Network 100BASE-TX Twisted Pair Network100BASE-FX Multimode Fiber-Optic Network 1000BASE-FX Fiber-Optic Network 1000BASE-FX Fiber-Optic Network Network Requirements Hardware Installation Considerations Prior to Installation Unpacking the SwitchContents of Switch Carton Required ToolsInstalling Optional Mini-GBICs PreparationInstallation Mini-GBIC with MT-RJ Connector Mini-GBIC with LC Connector Removing the Mini-GBICInstalling the Switch on a Flat Surface Installing the Rubber FeetGuidelines for Flat Surface Installation Chassis Bottom, Rubber Feet PlacementRack Mounting the Switch Area Guidelines for Switch Installation on Flat SurfaceGuidelines for Rackmount Installation Attaching Brackets and Installing in RackConnecting Stacking Cables Fastening the Switch to the RackConfiguring Switches in a Stack About SecureStack A2 Switch Operation in a StackConfiguring Switches in a Stack Recommended Procedures for New and Existing Stacks Installing a New Stackable System of Up to Eight SwitchesConnecting AC and RPS-SYS Power AC PowerSwitch Rear View C2RPS-SYS Redundant Power System 10 Accessing the RPS ConnectorWhat Is Needed Connecting to Console Port for Local ManagementStack Initialization Overview Connecting to an IBM or Compatible Device DB9 Male Console Port Pinout AssignmentsConnecting to a VT Series Terminal 12 Connecting an IBM PC or CompatibleConnecting to a Modem 13 Connecting a VT Series Terminal14 Connecting to a Modem Connecting to the Network Connecting Fiber-Optic Cables to Fixed MT-RJ Ports15 Connecting a Fiber-Optic Cable Segment to MT-RJ Port Connecting Fiber-Optic Cables to MT-RJ Mini-GBIC Ports Connecting to the Network Connecting Fiber-Optic Cables to LC Mini-GBIC Ports Connecting to the Network Connecting UTP Cables to RJ45 Ports 16 Connecting a UTP Cable Segment to RJ45 PortConnecting to the Network 17 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TX TX1+ RX1 TX2+ TX3+ RX3 RX2 TX4+ RX4 Completing the Installation Initial Logon to Switch ManagementCompleting the Installation Hardware Installation Troubleshooting This chapter provides information concerning the followingUsing Lanview Lanview LEDs of A2H254-16Lanview LEDs Color State Recommended ActionDown RPS Troubleshooting Checklist Configuration Guide for proper setupConfiguration Guide for the IP address Using the Reset Password Button Reset Password ButtonSwitch Specifications SpecificationsTable A-1 A2H254-16 Switch Specifications Physical EnvironmentalMini-GBIC Input/Output Specifications Table A-2 Mini-GBIC Input/Output Port SpecificationsMGBIC-LC01/MGBIC-MT01 Specifications 1000BASE-SX Gigabit Ethernet SpecificationsMGBIC-LC03 Specifications 1000BASE-SX MGBIC-LC09 Specifications 1000BASE-LX MGBIC-08 Specifications 1000BASE-ELX MGBIC-02 Specifications 1000BASE-TTable A-9 MGBIC-08 Optical Specifications Table A-11 MGBIC-02 SpecificationsRegulatory Compliance Console Port Pinout AssignmentsTable A-12 Compliance Standards Regulatory Compliance Regulatory Compliance Specifications Index NumericsIndex-2