Using LANVIEW
Table 4-1 LANVIEW LEDs (continued)
LED | Color State | Recommended Action |
|
|
|
DOWN | Off | No valid connection to switch |
|
| stackup connector. |
1.Make sure the switch connected to the stackup connector is powered on.
2.Replace cable with a known good one.
3.If the problem still exists, contact Enterasys Networks for technical support.
| Green | Solid. Valid connection to | None. |
|
| switch stackup connector. |
|
|
| Flashing. Information is being |
|
|
| transferred via the stacking |
|
|
| cable. |
|
|
|
|
|
UP | Off | No valid connection to switch | 1. Make sure the switch connected to the |
|
| stackdown connector. | stackdown connector is powered on. |
|
|
| 2. Replace cable with a known good one. |
|
|
| 3. If the problem still exists, contact |
|
|
| Enterasys Networks for technical |
|
|
| support. |
|
|
|
|
| Green | Solid. Valid connection to | None. |
|
| switch stackdown connector. |
|
|
| Flashing. Information is being |
|
|
| transferred via the stacking |
|
|
| cable. |
|
|
|
|
|
Manager | Off | Switch is operating as a | None. |
|
| Member in the stack. |
|
|
|
|
|
| Green | Solid. Switch is operating as | None. |
|
| the Manager of the stack. |
|