Lyngdorf Audio RP-1 owner manual Setting the Measurement Volume Level

Page 19

Setting the Measurement Volume Level

When setting the measurement volume level, it is important that you always judge whether the calibra- tion volume is too loud. The calibration volume should not be so loud that it causes:

uncomfortably loud sounds that are inconvenient to you or your environment, or

damage to your loudspeakers.

When the message ‘Connect and place mic. in focus pos.’ appears, connect the microphone to the mi- crophone input found on the back panel. Thereafter, place the microphone, using the microphone stand, in an appropriate focus/listening position. This location should be at your main listening position, typically more or less centered between the loudspeakers.

Make sure that the height and the orientation of the microphone corresponds to your typical listening height and direction as illustrated and do not block the line of sight between the microphone and the loudspeakers.

When the microphone has been correctly connected and placed in the focus position, you are ready to set the calibration volume. The calibration signal is a combination of the high and low frequency measur- ing signals and is only presented in your left loudspeaker. The measuring signals sound very artificial and disharmonic due to the fact that they are composed of pure tones at different frequencies.

Press Enter to confirm and to commence the calibration process.

If the RP-1 is connected before the volume control of your amplifier e.g. when using Option 2 or a ‘tape 2’ loop as described in Option 3 in the “Connecting the RP-1” chapter, be aware that the volume control of your amplifier is set at an appropriate level when making the RoomPerfect calibration.

The volume control should be set at 0dB, which typically is in the “12 o´ clock” po- sition. This setting must be used again if you wish to add additional RoomPerfect measurements later.

The test signal will start and shortly thereafter the RP-1 will suggest an initial estimate of the desired maximum calibration volume, displayed as ‘Adjust level: XX up/down - Retry/Save Current’

Please raise or lower the volume by pressing the Up/Down buttons on the RP-1 front panel or remote control towards the desired number of steps shown on the display but ensure you avoid clipping, uncom- fortably loud levels and damage to the loudspeakers. Continue choosing Retry for a re-estimation of the desired maximum calibration volume, until an appropriate calibration volume is reached. If you find the suggested calibration volume too loud simply turn down the volume to an appropriate level and choose Save current.

19

Image 19
Contents RP-1 RoomPerfect Page Table of Contents Unpacking the RP-1 Operating VoltageSerial Number Registration Introduction Remote control AccessoriesControls Front PanelRear Panel Display IndicatorsPage Remote Control Page Connecting to sources and amplifiers Connecting the RP-1Integrated amp / Preamp-poweramp RP-1 Setup options of Main and Line outputs Navigating the Menu System Menu SystemMenu Tree Voicing Introduction to RoomPerfectGlobal Listening Focus ListeningRoomPerfect Guided SetupSetting the Measurement Volume Level Room Measurements Focus MeasurementAdding more Room Measurements Calculation of Focus and Global Filters Change Focus Position Advanced OptionsMeasure Room Pos RoomCorrection RoomKnowledgeDisplay Brightness Display TimeoutDisplay Input ConnectionComm Address Advanced SetupInput Sensitivity CommunicationRouting Line Out LevelFilter Type Crossover FrequencyRemote Control DelayFirmware Versions Factory ResetRoomPerfect TroubleshootingRP-1 Firmware Upgrading Balanced Inputs ConnectorsCleaning and Maintenance Mains ConnectorMains Technical SpecificationsAudio ProtectionTechnical Assistance Voicing Curves AppendixPage