Lyngdorf Audio RP-1 owner manual RoomKnowledge, RoomCorrection

Page 24

‘Add more room meas.? Yes/No’ will show in the display:

choose Yes to add another room measurement or,

choose No to stop adding more room measurements. If No is chosen the RP-1 is will return to full scale output.

‘Save room measurement(s)? Yes/No’ will hereafter be shown.

choose Yes to save the performed room measurement,

and No to exit without saving any of the performed measurements.

Adding one or more room measurements leads to a re-calculation of both filters (i.e. Global and Focus filters) due to the fact that more of room’s acoustic properties have been learned, something that affects these filters.

When adding room measurements, make sure the system volume is the same for all measurements. Whether adding more room measurements now or later.

If you can´t remember the volume setting, we recommend to delete the filter and start over.

RoomKnowledge

The RoomKnowledge index is a parameter that tells how much of the room’s acoustical properties have been learned. A high RoomKnowledge ( 90%) means that most of the room’s acoustical properties have been learned. The more room measurements you add, the higher the RoomKnowledge will become. The more that the acoustical properties of the room are learned, the greater the accuracy of the room correction.

RoomCorrection

The RoomCorrection index is a measure of how much processing is being employed in the room correc- tion filter. To some extent the RoomCorrection index reflects how audible the correction is. However, the same amount of processing can sound very different due to placement in frequency of the processing. For low values (below 10%) of the room correction index, only subtle correction is needed to the original sound in the room. With high room correction index values more extensive processing is employed.

24

Image 24
Contents RP-1 RoomPerfect Page Table of Contents Operating Voltage Unpacking the RP-1Serial Number Registration Introduction Accessories Remote controlFront Panel ControlsDisplay Indicators Rear PanelPage Remote Control Page Connecting the RP-1 Connecting to sources and amplifiersIntegrated amp / Preamp-poweramp RP-1 Setup options of Main and Line outputs Menu System Navigating the Menu SystemMenu Tree Introduction to RoomPerfect Global ListeningFocus Listening VoicingGuided Setup RoomPerfectSetting the Measurement Volume Level Focus Measurement Room MeasurementsAdding more Room Measurements Calculation of Focus and Global Filters Advanced Options Change Focus PositionMeasure Room Pos RoomKnowledge RoomCorrectionDisplay Timeout DisplayInput Connection Display BrightnessAdvanced Setup Input SensitivityCommunication Comm AddressLine Out Level RoutingCrossover Frequency Filter TypeDelay Remote ControlFactory Reset Firmware VersionsTroubleshooting RoomPerfectRP-1 Firmware Upgrading Connectors Cleaning and MaintenanceMains Connector Balanced InputsTechnical Specifications AudioProtection MainsTechnical Assistance Appendix Voicing CurvesPage