Stacking Dell PowerConnect 7000 Series Switches
If PoE is enabled on a switch port shortly before a master failover and the hardware status change had not yet been communicated to the backup unit, the switch will continue to provide PoE power even though PoE is not enabled for the port in the configuration on the new master. The user can correct this configuration mismatch by
Stack Member Failover
When a unit in the stack fails, the master unit removes the failed unit from the stack. No changes or configuration settings are applied to the other stack members; however, dynamic protocols will try to
Failover Scenarios
This section describes examples of what happens when a stack member or the master unit fails.
Scenario 1
In this example, the stack has four members that are connected through a
Switch 1
Switch 2 Standby
Switch 3 Master
Switch 4
When all four units are up and running, the show switch CLI command gives the following output:
console#show switch
Switch | Managemen | Standby | Preconfig | Switch | Code | |
Status | Status | Model ID | Model ID | Status | Version | |
1 | Stack Mbr | Standby | PCT7048 | PCT7048 | OK | 4.0.0.6 |
2 | Stack Mbr |
| PCT7048 | PCT7048 | OK | 4.0.0.6 |
3 | Mgmt Sw |
| PCT7048 | PCT7048 | OK | 4.0.0.6 |
4 | Stack Mbr |
| PCT7048 | PCT7048 | OK | 4.0.0.6 |
At this point, if Unit 2 is powered off or rebooted due to an unexpected failure, show switch gives the following output:
Page 19