Dell 7000 Series manual NSF Re-convergence Timing, Parameter Timing

Page 32

Stacking Dell PowerConnect 7000 Series Switches

NSF Re-convergence Timing

As mentioned in the previous section, NSF protects against failures by check-pointing information to a standby unit. In an NSF-protected stack, the worst-case scenario is when the master unit fails. The following statistics show representative re-convergence times of an NSF-enabled standby switch as measured from the detection of failure. With NSF enabled, data plane forwarding continues non-stop on the non-failed switches while the standby unit converges the control plane protocols using the check-pointed information. The re-convergence times given below include re-establishing communication with the upper layer protocol peers, synchronization of shared information with the peer, and re-establishment of any data plane forwarding paths around the failed master unit.

Medium Configuration

8 switches stacked

100 VLANs, all ports are members of all VLANs

4/4 static/dynamic lags with 8 members each

3 MSTP instance with VLANs

30 ACLs applied on 30 interfaces

10 Diffserv service interfaces with policies on 10 interfaces

6 VLAN routing interfaces

128 L2 Multicast group entries

512 ARP entries

128 Unicast routes

Parameter

Timing

L2 loss duration (non-failed or rerouted stack member)

0 msec

L2 loss duration (failed/rerouted stack member)

10 msec

L3 loss duration (failed/rerouted stack member)

12 msec

IPMC loss duration (failed/rerouted stack member)

12 msec

L2 convergence time

25.70 sec

L3 convergence time

25.410 sec

IPMC convergence time

25.420 sec

Total convergence time

25.420 sec

Page 30

Image 32
Contents Stacking Dell PowerConnect Series Switches Dell Technical White PaperStacking Dell PowerConnect 7000 Series Switches Contents Stacking and Management IntroductionApplicability Stacking and Performance Stacking and RedundancyDual Stacking Modules Configured in a Ring Mixing M6348 and PC7000 Series Switches in a Stack Power-Up Sequencing ConsiderationsConsole#boot auto-copy-sw allow-downgrade Initial Installation and Power-up of a Stack Selecting the Master Unit Selecting the Standby UnitAutomatic Update Updating the Firmware on a StackManual Update Creating a Separate Vlan for File Downloads FTPFrom the Switching Vlan Vlan Membership page, click Add Navigate to the Routing IP IP Interface Configuration Page Stacking Dell PowerConnect 7000 Series Switches Click Apply Adding a Stack Member with Minimal Interruption Removing a Stack Member with Minimal Interruption Effect of Master Failover on PoE Devices Merging Two Operational StacksMaster Failover Scenario Stack Member FailoverFailover Scenarios Stack Split Stack Split with Manager Failure Nonstop Forwarding Initiating a Warm Failover of the Manager Unit Nonstop Forwarding ScenarioNonstop Forwarding Example NSF Scenario Configuration via CLI RouterStack Switch Switch NSF Example NSF Re-convergence Timing Parameter TimingStacking CLI Commands Small ConfigurationStacking Web Interface Summary