Dell 7000 Series manual NSF Scenario Configuration via CLI, Router

Page 27

Stacking Dell PowerConnect 7000 Series Switches

NSF Scenario Configuration via CLI

Router 1:

configure terminal hostname Router_1 ip multicast

ip pim rp-address 192.168.10.1 239.0.1.1 255.255.255.0 ip pim sparse

vlan database vlan 10

exit

interface vlan 10

ip address 192.168.10.1 255.255.255.0 ip pim

exit

router ospf router-id 1.1.1.1

network 192.168.0.0 0.0.255.255 area 0 enable

exit

interface Port-channel1

description “LAG to switch stack – gi1/0/10, gi1/0/20” switchport mode trunk

switchport trunk native vlan 10 switchport trunk allowed vlan remove 1

exit

interface GigabitEthernet 1/0/1 description “Interface to multicast source” no spanning-tree

switchport access vlan 10 exit

interface GigabitEthernet 1/0/10 no spanning-tree auto-portfast channel-group 1 mode auto

exit

interface GigabitEthernet 1/0/20 no spanning-tree auto-portfast channel-group 1 mode auto

exit

-----------------------------------------

Page 25

Image 27
Contents Dell Technical White Paper Stacking Dell PowerConnect Series SwitchesStacking Dell PowerConnect 7000 Series Switches Contents Introduction ApplicabilityStacking and Management Stacking and Redundancy Stacking and PerformanceDual Stacking Modules Configured in a Ring Power-Up Sequencing Considerations Mixing M6348 and PC7000 Series Switches in a StackConsole#boot auto-copy-sw allow-downgrade Initial Installation and Power-up of a Stack Selecting the Standby Unit Selecting the Master UnitUpdating the Firmware on a Stack Automatic UpdateManual Update FTP Creating a Separate Vlan for File DownloadsFrom the Switching Vlan Vlan Membership page, click Add Navigate to the Routing IP IP Interface Configuration Page Stacking Dell PowerConnect 7000 Series Switches Click Apply Adding a Stack Member with Minimal Interruption Removing a Stack Member with Minimal Interruption Merging Two Operational Stacks Master FailoverEffect of Master Failover on PoE Devices Stack Member Failover Failover ScenariosScenario Stack Split Stack Split with Manager Failure Nonstop Forwarding Nonstop Forwarding Scenario Initiating a Warm Failover of the Manager UnitNonstop Forwarding Example Router NSF Scenario Configuration via CLIStack Switch Switch NSF Example Parameter Timing NSF Re-convergence TimingSmall Configuration Stacking CLI CommandsSummary Stacking Web Interface