INTRODUCTION

Owner Orientation

The illustrations are for typical circumstances and are meant to familiarize you with the installation options available with your transfer switch.

Local codes, appearance, and distances are the factors that must be considered when negotiating with an installation professional. As the distance from the existing electrical service increases, compensation in wiring materials must be allowed for.This is necessary to comply with local codes and overcome electrical voltage drops.

The factors mentioned above will have a direct effect on the overall price of your transfer switch installation.

NOTE: Your installer must check local codes AND obtain permits before installing the system.

Read and follow the instructions given in this manual.

Follow a regular schedule in caring for and using your transfer switch, as specified in the manual.

Installer Responsibilities

Read and observe the safety rules.

Read and follow the instructions given in this manual.

Check federal, state and local codes, standards and regulations.

Ensure generator is not overloaded with selected loads.

Equipment Description

These transfer switches are intended to operate compatible electrical loads of normal residential installations.The load is connected either to utility power (normal) or home standby power (generator).

These manual transfer switches are equipped with two circuit breakers (“GENERATOR SUPPLY” and “UTILITY SUPPLY”) and a mechanical interlock.The “GENERATOR SUPPLY” circuit breaker provides power from the generator to the load devices wired to the manual transfer switch.The “UTILITY SUPPLY” circuit breaker provides utility power from the distribution panel to the load devices wired to the manual transfer switch.

The mechanical interlock allows the circuit breakers for either the generator power “GENERATOR SUPPLY” or the utility power “UTILITY SUPPLY” to be turned on to provide power to the selected house loads.These manual transfer switches will not allow utility line power and generator power to be connected to a load device at the same time.

If utility line power is restored while generator power is being used, there will be no affect on the generator or transfer switch components.When utility power is restored, follow the instructions in the section “System Operation”.

5

Image 5
Contents 50A Nema 1 / Nema 3R Manual Transfer Switch Table of Contents Contact with live parts can cause electric shock or burn Important Safety InstructionsFor the Home Owner For the Installing Dealer/ContractorIntroduction Equipment Description Installer ResponsibilitiesOwner Orientation Mounting Guidelines InstallationUnpacking Isolation Essential CircuitTypical Installation Diagram for Transfer Switch Power Wiring InterconnectionsSystem Operation SpecificationsWhen Calling the Factory Model 071004 Nema Model 071005 Nema 3R Transfer Switch Service PartsLimited Warranty Fonctionnement DU Système Table DES MatièresAvertissement Responsabilités de lInstallateur Au Détaillant ou à lEntrepreneur Procédant à lInstallationIntroduction Conseils au PropriétaireDéballage InstallationDescription de lÉquipement Alimentation de la Isolation DES Circuits EssentielsInterconnexions du Câblage dAlimentation Si vous Devez Communiquer avec lUsine Fonctionnement DU SystèmeCaractéristiques Période DE Garantie Funcionamiento DEL Sistema Tabla DE ContenidoPrecaución AdvertenciaPara el Propietario Doméstico IntroducciónResponsabilidades del Instalador Orientación para el PropietarioDescripción del Equipo Desempaque Instalación120V Aislamiento DE LOS Circuitos FundamentalesInterconexiones de Cableado de Energía Si Necesita Llamar a Fábrica Funcionamiento DEL SistemaEspecificaciones Período DE Garantía