Motorola manual MVME3100 vmeCfg -s -o1

Page 36

Chapter 3 MOTLoad Firmware

Inbound window 0 (ITAT0) is not enabled; Virtual FIFO at 256 bytes, 2eSST timing at SST320, respond to 2eSST, 2eVME, MBLT, and BLT cycles, A32 address space, respond to Supervisor, User, Program, and Data cycles. Image maps from 0x00000000 to 0x1FFF0000 on the VMbus, translates 1x1 to the PCI-X bus (thus 1x1 to local memory). To enable this window, set bit 31 of ITAT0 to 1.

Note For Inbound Translations, the Upper Translation Offset Register needs to be set to 0xFFFFFFFF to ensure proper translations to the PCI-X Local Bus.

MVME3100> vmeCfg –s –o1

Displaying the

selected Default VME

Setting

 

 

- interpreted as

follows:

 

 

 

Outbound Image

1

Attribute Register

= 80001462

 

 

Outbound Image

1

Starting Address Upper Register

=

00000000

Outbound Image

1

Starting Address Lower Register

=

91000000

Outbound Image

1

Ending Address Upper Register =

00000000

Outbound Image

1

Ending Address Lower Register =

AFFF0000

Outbound Image

1

Translation Offset

Upper Register

= 00000000

Outbound Image

1

Translation Offset

Lower Register

= 70000000

Outbound Image

1

2eSST Broadcast Select Register

=

00000000

MVME3100>

 

 

 

 

 

Outbound window 1 (OTAT1) is enabled, 2eSST timing at SST320, transfer mode of 2eSST, A32/D32 Supervisory access. The window accepts transfers on the PCI-X Local Bus from 0x91000000-0xAFFF0000 and translates them onto the VMEbus using an offset of 0x70000000, thus an access to 0x91000000 on the PCI-X Local Bus becomes an access to 0x01000000 on the VMEbus.

MVME3100> vmeCfg –s –o2

Displaying the

selected Default VME

Setting

 

 

- interpreted as

follows:

 

 

 

Outbound Image

2

Attribute Register

= 80001061

 

 

Outbound Image

2

Starting Address Upper Register

=

00000000

Outbound Image

2

Starting Address Lower Register

=

B0000000

Outbound Image

2

Ending Address Upper Register =

00000000

Outbound Image

2

Ending Address Lower Register =

B0FF0000

Outbound Image

2

Translation Offset

Upper Register

= 00000000

Outbound Image

2

Translation Offset

Lower Register

= 40000000

Outbound Image

2

2eSST Broadcast Select Register

=

00000000

MVME3100>

 

 

 

 

 

Outbound window 2 (OTAT2) is enabled, 2eSST timing at SST320, transfer mode of SCT, A24/D32 Supervisory access. The window accepts transfers on the PCI-X Local Bus from 0xB0000000-0xB0FF0000 and translates them onto the VMEbus using an offset of 0x40000000, thus an access to 0xB0000000 on the PCI-X Local Bus becomes an access to 0xF0000000 on the VMEbus.

MVME3100> vmeCfg –s –o3

Displaying the

selected Default VME

Setting

- interpreted as

follows:

 

 

Outbound Image

3

Attribute Register

= 80001061

Outbound

Image

3

Starting Address Upper

Register = 00000000

Outbound

Image

3

Starting Address Lower

Register = B3FF0000

24MVME3100 Single-Board Computer Installation and Use (V3100A/IH1)

Image 36
Contents Installation and Use Page Safety Summary Flammability CE Notice European Community Limited and Restricted Rights Legend Contents Functional Description Specifications List of Figures 13. MVME721 Host I/O Connector J10 Pin Assignments List of TablesOverview of Contents About This ManualComments and Suggestions Conventions Used in This ManualHardware Preparation and Installation IntroductionDescription Getting StartedOverview of Startup Procedures Unpacking GuidelinesStartup Overview Hardware Configuration MVME3100 LayoutMVME3100 Board Layout Configuration Switch S4 Configuration Switch S4 SettingsSetting Switch Pos OFF Factory Default Geographical Address Switch S3 Geographical Address Switch AssignmentsSlot Geographical Address Settings PMC I/O Voltage Configuration RTM Seeprom Address Switch S1RTM Eeprom Address Switch Assignments Function Not UsedHardware Installation Installing the MVME3100 into a ChassisEeprom Address Settings Device Address A20MVME3100 Connectors MVME721 Rear Transition Module ConnectorsConnector Function Connection to PeripheralsCompleting the Installation Applying Power Switches and IndicatorsFront-Panel LED Status Indicators Startup and OperationMVME721 LED Status Indicators Additional Onboard Status IndicatorsGenet DS3 MOTLoad Commands MOTLoad FirmwareOverview MOTLoad Implementation and Memory RequirementsMOTLoad Utility Applications MOTLoad TestsUsing MOTLoad Command Line InterfaceCommand Line Help Command Line RulesMOTLoad Command List MOTLoad CommandsCommand Description DownLoad ErrorDisplayNetBoot EchoCommand Description NetStats ResetNoCm PciDataRdMOTLoad Commands Default VME Settings MVME3100 vmeCfg -s -mMVME3100 vmeCfg -s -o1 Firmware Settings CR/CSR SettingsDisplaying VME Settings Editing VME Settings Deleting VME Settings Restoring Default VME SettingsRemote Start Slot Position CS/CSR Starting Address Alternate Boot Images and Safe Start Firmware Startup Sequence Following ResetFirmware Scan for Boot Image Address UsageValid Boot Images Checksum AlgorithmName Type Size MOTLoad Image Flags User ImagesMOTLoad Image Flags Name Value InterpretationAlternate Boot Data Structure MOTLoad Firmware Features MVME3100 Features SummaryFeature Description Functional DescriptionFunctional Description MVME721 RTM Features Summary Block Diagrams MVME3100 Block DiagramProcessor System MemoryLocal Bus Interface Control and Timers Logic I2C Serial Interface and DevicesFlash Memory Ethernet Interfaces Asynchronous Serial PortsPCI/PCI-X Interfaces and Devices MPC8540 PCI-X InterfaceTSi148 VME Controller Serial ATA Host ControllerPCI-X-to-PCI-X Bridges PCI Mezzanine Card SlotsGeneral-Purpose Timers Real-time Clock BatteryPMC Expansion Reset Control Logic Debug SupportPin Assignments Connectors PMC Expansion Connector J4PMC Expansion Connector J4 Pin Assignments Pin SignalPAR Ethernet Connectors GENET1/J41B, GENET2/J2B, ENET1/J2A Ethernet Connectors Pin AssignmentPin # Signal 1000 Mb/s 10/100 Mb/s PCI Mezzanine Card PMC Connectors J11 J14, J21 J23 PMC Slot 1 Connector J11 Pin AssignmentsPMC Slot 1 Connector J12 Pin Assignments PMC Slot 1 Connector J13 Pin Assignments PMC Slot 1 Connector J14 Pin Assignments PMC Slot 2 Connector J21 Pin Assignments PMC Slot 2 Connector J22 Pin Assignments PMC Slot 2 Connector J23 Pin Assignments Serial Port Connectors COM1/J41A, COM2-COM5/J2A-D 10. COM Port Connector Pin AssignmentsVMEbus P1 Connector 11. VMEbus P1 Connector Pin AssignmentsVMEbus P2 Connector 12. VME P2 Connector PinoutsPin P2-Z P2-A P2-B P2-C P2-D MVME721 PMC I/O Module PIM Connectors J10, J14 13. MVME721 Host I/O Connector J10 Pin AssignmentsPlanar sATA Power Connector J30 USB Connector J2714. Planar sATA Power Connector J30 Pin Assignments 15. USB Connector J27 Pin AssignmentsSATA Connectors J28 and J29 16. sATA Connectors J28 and J29 Pin AssignmentsHeaders Boundary Scan Header J24Processor COP Header J25 18. Processor COP Header J25 Pin AssignmentsPower Requirements Environmental SpecificationsModel Power Characteristics SpecificationsAppendix a Specifications Related Documentation Motorola Computer Group DocumentsTable B-1. Motorola Computer Group Documents Manufacturers’ Documents Table B-2. Manufacturers’ DocumentsDocument Title and Source Publication Number Table B-2. Manufacturers’ Documents Related Specifications Table B-3. Related SpecificationsIeee http//standards.ieee.org/catalog