RAD Data comm ARC-101 operation manual Chapter Operation, Name Description

Page 31

Chapter 3

Operation

The ARC-101 has several LED indicators, providing information on the ARC-101's general status, as well as right and left module status

(see Figure 3-1). The indicators are ON, OFF, or BLINK, depending on the state of ARC-101. Table 3-1 lists the functions of the front panel indicators.

 

 

Figure 3-1 ARC-101 Front Panel

 

 

Table 3-1 ARC-101 LED Indicators

 

 

 

Name

 

Description

 

 

 

PWR (green)

ON

When ARC 101 is powered.

 

 

 

FLT (red)

BLINKS

Error detected during self-test

 

 

If the error is in one of the modules, the module's two LEDs blink;

 

 

In case of a system error, the two module's LEDs blink.

 

ON

During self-test

ATM (green)

ON

During active ATM connections on the module's port:

 

 

That is when no HEC error was detected during the last second and,

 

 

at least one cell was received and transmitted in the last second.

 

 

 

SYNC (green)

ON

When the module's port is synchronized (no alarm)

 

OFF

During local alarm (a fault is detected on the receive side of ARC-101).

 

BLINKS

During remote alarm the remote unit signals that a fault has been

 

 

detected.

 

 

 

Operating Procedure

3-1

Image 31
Contents RAD data communications Headquarters US East US West ARC-101Page Warranty Safety Status Ports Safety WarningsRegulatory Information Supplementary Information SafetyContents Operation List of Figures List of Tables General Description Chapter IntroductionInterfaces Supported ARC-101 FeaturesTraffic Management Loopback Mode Specifications RM-1 Ordering ARC-101/#RM-2 Introduction Specifications Unpacking GeneralRack Mounting Instructions Site RequirementsATM Connection Control Port InstallationCable Connections Two UnitsPinout Changing Control Port ModeGrounding AC Power ConnectionST13S/155 Module Module CharacteristicsARC-101 Modules SC13M/155 ModuleCX/BNC/155 Module ST13L/155 Module12 UTP/155 Module Front Panel UTP/155 ModuleT3 Module E3 ModuleModules E1 and E1/LTUInserting Modules Removing Modules Inserting Removing ModulesFor E1 and E1/LTU Jumper Settings17 T3 Jumper Locations Jumper Settings for T3Installation Name Description Chapter OperationOperating Procedure ARC-101 Block Diagram Operation Introduction Accessing, Using and Exiting Monitor ModeARC Menu General Information Configuration WindowScreen Explanations General Information WindowALL Changes will be SAVED. are YOU SURE? Y/N ConfigurationSystem ParametersLeft Module Right/Left Module ConfigurationAscii Terminal Configuration Ascii Terminal ConfigurationDiagnostics Diagnostics WindowPerformance Monitoring Window Link Status SLM SONET/SDH Link Status WindowLOS LOC OOF AIS RDI BIP Febe T3 Link Status Window Errors/Alarms displayed in Plcp ModeE1 Link Status Window ATM TrafficATM Status E3 Link Status WindowCounter precision is 1/10,000 Software Management Performance Monitoring Window