RAD Data comm ARC-101 operation manual SONET/SDH Link Status Window, Slm

Page 42

 

Chapter 4. Software Management

ARC-101Installation & Operation Manual

 

 

 

 

 

 

 

 

 

 

SONET/SDH Link Status Window

 

 

 

 

 

 

 

LOS

Loss of Signal

 

 

 

 

 

 

LOF

Loss of Frame

 

 

 

 

 

 

LOP

Loss of Pointer

 

 

 

 

 

 

LOC

Loss of Cell Delineation

 

 

 

 

 

 

SLM

Signal Cable Mismatch

 

 

 

 

 

 

 

 

 

 

Line AIS

Line Alarm Indication Signal

 

 

 

 

 

 

Path AIS

Path Alarm Indication Signal

 

 

 

 

 

 

Line FERF/RDI

Line Far End Receive Failure/Remote Defect Indicator

 

 

 

 

 

 

Path FERF/RDI

Path Far End Receive Failure/Remote Defect Indicator

 

 

 

 

 

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the "Last Sec." column indicates that there are one or more errors in the last second. The number in the "All" column is equal to the cumulative number of seconds in which errors occurred.

Section BIP

Section Bit Interleaved Parity

 

 

Line BIP

Line Bit Interleaved Parity

 

 

Path BIP

Path Bit Interleaved Parity

 

 

Line FEBE

Line Far End Block Error

 

 

Path FEBE

Path Far End Block Error

 

 

T3 Link Status Window - Errors/Alarms displayed in Direct (HEC) Mode

LOS

Loss of Signal

 

 

OOF

Out of Frame

 

 

LOC

Loss of Cell Delineation

 

 

AIS

Alarm Indication Signal

 

 

Yellow

Yellow Alarm

 

 

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the "Last Sec." column indicates that there are one or more errors in the last second.

BIP

Bit Interleaved Parity

 

 

FEBE

Far End Block Error

 

 

P1/P2

P1/P2

 

 

4-8

Performance Monitoring Window

Image 42
Contents ARC-101 RAD data communications Headquarters US East US WestPage Warranty Safety Warnings Safety Status PortsRegulatory Information Safety Supplementary InformationContents Operation List of Figures List of Tables Chapter Introduction General DescriptionARC-101 Features Interfaces SupportedTraffic Management Loopback Mode Specifications Ordering ARC-101/# RM-1RM-2 Introduction Specifications General UnpackingSite Requirements Rack Mounting InstructionsTwo Units InstallationCable Connections ATM Connection Control PortChanging Control Port Mode PinoutAC Power Connection GroundingSC13M/155 Module Module CharacteristicsARC-101 Modules ST13S/155 ModuleST13L/155 Module CX/BNC/155 ModuleUTP/155 Module 12 UTP/155 Module Front PanelE3 Module T3 ModuleE1 and E1/LTU ModulesInserting Removing Modules Inserting Modules Removing ModulesJumper Settings For E1 and E1/LTUJumper Settings for T3 17 T3 Jumper LocationsInstallation Chapter Operation Name DescriptionOperating Procedure ARC-101 Block Diagram Operation Accessing, Using and Exiting Monitor Mode IntroductionARC Menu General Information Window Configuration WindowScreen Explanations General InformationParameters ConfigurationSystem ALL Changes will be SAVED. are YOU SURE? Y/NRight/Left Module Configuration Left ModuleAscii Terminal Configuration Ascii Terminal ConfigurationDiagnostics Window DiagnosticsPerformance Monitoring Window Link Status SONET/SDH Link Status Window SLMT3 Link Status Window Errors/Alarms displayed in Plcp Mode LOS LOC OOF AIS RDI BIP FebeE3 Link Status Window ATM TrafficATM Status E1 Link Status WindowCounter precision is 1/10,000 Software Management Performance Monitoring Window