RAD Data comm ARC-101 operation manual Configuration, System Parameters

Page 37

ARC-101Installation & Operation Manual

Chapter 4. Software Management

 

 

To Save the Configuration:

CONFIGURATION

1.System Parameters

2.Left Module

3.Right Module

4.ASCII Terminal Configuration

5.Set Default Parameters

6.Save Changes

ESC. Exit

After making all changes, return to the Configuration window, and select option 6. If a new value was entered at any menu, the following prompt will appear upon exiting the menu:

ALL CHANGES WILL BE SAVED. ARE YOU SURE? (Y/N)

Type Y for "Yes", or press any other key for "No".

Note

To Set Default Parameters

Note

If you change a module, the ARC-101 will reboot with its default parameters.

To return all configuration parameters to their factory defaults, go to the Configuration window, and select option 5.

If you set the Default Parameters, the Baud Rate parameter will be changed and saved as 9600. The ASCII Terminal Baud will be changed to 9600 the next time the ARC is restarted.

System

To set system parameters, select option 1 from the Configuration menu.

Parameters

 

 

 

 

 

 

 

 

 

 

 

SYSTEM PARAMETERS

 

 

 

1.

FIFO Congestion Threshold: 90%

 

 

2.

EFCI Marking:

Disable

 

 

3.

CLP Dropping:

Disable

 

 

4.

Early Packet Discard:

Disable

 

 

ESC. Exit

 

 

 

Select item from the menu:

 

 

 

 

 

 

 

 

 

 

FIFO Congestion

(Default - 75%); options: 25%, 50%, 75%, 90%, 100%

Threshold

 

 

 

 

The FIFO threshold in which the ARC-101 will enter the "congestion" state

Configuration Window

4-3

Image 37
Contents RAD data communications Headquarters US East US West ARC-101Page Warranty Safety Status Ports Safety WarningsRegulatory Information Supplementary Information SafetyContents Operation List of Figures List of Tables General Description Chapter IntroductionInterfaces Supported ARC-101 FeaturesTraffic Management Loopback Mode Specifications RM-1 Ordering ARC-101/#RM-2 Introduction Specifications Unpacking GeneralRack Mounting Instructions Site RequirementsCable Connections InstallationTwo Units ATM Connection Control PortPinout Changing Control Port ModeGrounding AC Power ConnectionARC-101 Modules Module CharacteristicsSC13M/155 Module ST13S/155 ModuleCX/BNC/155 Module ST13L/155 Module12 UTP/155 Module Front Panel UTP/155 ModuleT3 Module E3 ModuleModules E1 and E1/LTUInserting Modules Removing Modules Inserting Removing ModulesFor E1 and E1/LTU Jumper Settings17 T3 Jumper Locations Jumper Settings for T3Installation Name Description Chapter OperationOperating Procedure ARC-101 Block Diagram Operation Introduction Accessing, Using and Exiting Monitor ModeARC Menu Screen Explanations Configuration WindowGeneral Information Window General InformationSystem ConfigurationParameters ALL Changes will be SAVED. are YOU SURE? Y/NLeft Module Right/Left Module ConfigurationAscii Terminal Configuration Ascii Terminal ConfigurationDiagnostics Diagnostics WindowPerformance Monitoring Window Link Status SLM SONET/SDH Link Status WindowLOS LOC OOF AIS RDI BIP Febe T3 Link Status Window Errors/Alarms displayed in Plcp ModeATM Status ATM TrafficE3 Link Status Window E1 Link Status WindowCounter precision is 1/10,000 Software Management Performance Monitoring Window