RAD Data comm ARC-101 ATM Traffic, ATM Status, E3 Link Status Window, E1 Link Status Window

Page 44

Chapter 4. Software ManagementARC-101Installation & Operation Manual

E3 Link Status Window

LOS

Loss of Signal

 

 

OOF

Out of Frame

 

 

LOC

Loss of Cell Delineation

 

 

AIS

Alarm Indication Signal

 

 

RDI

Remote Defect Indicator

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the "Last Sec." column indicates that there are one or more errors in the last second. The number in the "All" column is equal to the cumulative number of seconds in which errors occurred.

BIP

Bit Interleaved Parity

 

 

FEBE

Far End Block Error

 

 

E1 Link Status Window

LOC

Loss of Cell Delineation

A '0'' in the "Last Sec" columns of the Alarms listed above, indicates that no errors have occurred. A '1' in the "Last Sec." column indicates that there are one or more errors in the last second. The number in the "All" column is equal to the cumulative number of seconds in which errors occurred.

ATM Traffic

ATM cell statistics are displayed in this window - the number of events that

Monitoring

have occurred since counters reset or overflow in the right and left

 

modules:

Cells transmitted

Cells received

Cells discarded due to HEC errors

ATM STATUS

 

 

 

 

Left Module

Last Sec.

All

Right Module

Last Sec.

All

Cells

1200

412000

Cells

1990

412010

Transmitted:

 

 

Transmitted:

 

 

Cells

1208

412020

Cells

1990

412000

Received

 

 

Received

 

 

Cells

 

 

Cells

 

 

Discarded:

 

 

Discarded:

 

 

(HEC errors)

0

0

(HEC errors)

0

0

Time since the last Counters Reset:

00:34:46

 

 

 

 

 

 

Press ESC to exit

 

 

 

 

 

 

4-10

Performance Monitoring Window

Image 44
Contents ARC-101 RAD data communications Headquarters US East US WestPage Warranty Safety Warnings Safety Status PortsRegulatory Information Safety Supplementary InformationContents Operation List of Figures List of Tables Chapter Introduction General DescriptionARC-101 Features Interfaces SupportedTraffic Management Loopback Mode Specifications RM-2 Ordering ARC-101/#RM-1 Introduction Specifications General UnpackingSite Requirements Rack Mounting InstructionsInstallation Cable ConnectionsTwo Units ATM Connection Control PortChanging Control Port Mode PinoutAC Power Connection GroundingModule Characteristics ARC-101 ModulesSC13M/155 Module ST13S/155 ModuleST13L/155 Module CX/BNC/155 ModuleUTP/155 Module 12 UTP/155 Module Front PanelE3 Module T3 ModuleE1 and E1/LTU ModulesInserting Removing Modules Inserting Modules Removing ModulesJumper Settings For E1 and E1/LTUJumper Settings for T3 17 T3 Jumper LocationsInstallation Chapter Operation Name DescriptionOperating Procedure ARC-101 Block Diagram Operation ARC Menu Accessing, Using and Exiting Monitor ModeIntroduction Configuration Window Screen ExplanationsGeneral Information Window General InformationConfiguration SystemParameters ALL Changes will be SAVED. are YOU SURE? Y/NRight/Left Module Configuration Left ModuleAscii Terminal Configuration Ascii Terminal ConfigurationPerformance Monitoring Window Diagnostics WindowDiagnostics Link Status SONET/SDH Link Status Window SLMT3 Link Status Window Errors/Alarms displayed in Plcp Mode LOS LOC OOF AIS RDI BIP FebeATM Traffic ATM StatusE3 Link Status Window E1 Link Status WindowCounter precision is 1/10,000 Software Management Performance Monitoring Window