RAD Data comm ARC-101 operation manual Operating Procedure

Page 32

Chapter 3. OperationARC-101Installation & Operation Manual

 

3.1 Operating Procedure

 

 

Note

The interface modules are not hot-swappable. If you install or change

 

modules, make sure to first disconnect power to the ARC-101, and then

 

remove/install modules slowly and carefully (so as not to damage the modules

 

or the ARC-101 enclosure). See section 2.6.

Turning on the ARC-101

Normal

Operation

Turning off the ARC-101

Procedure in

Case of

Malfunctioning

Install the ARC-101 as described in Chapter 2. Make sure that the power cord is connected to the ARC-101's power connector on the rear panel. Plug the other end of the power cord into the mains outlet. The PWR indicator on the front panel should light.

Upon power-up, the ARC-101 goes through a self-test that takes about

40 seconds to complete. The FLT indicator is ON during the self-test. After the self-test is completed, if no faults have been detected, the FLT indicator is OFF. Detailed test results can e viewed from an ASCII terminal connected to the ARC-101's CONTROL port.

The ARC-101 operates unattended. During normal operation, the PWR indicators should light continuously, the FLT indicator should be OFF, the ATM indicator should light up when ATM traffic passes through the module, and the SYNC indicator should light up continuously.

To turn off the ARC-101, disconnect the power cord from the mains outlet.

The following table lists several common problems and their possible solutions.

The PWR LED does not light up

Check the power cord connection on the back of the unit and at the

 

mains outlet.

 

Verify power availability at the mains outlet.

 

 

Fault (FLT) LED blinks

Unplug the unit (power OFF). Make sure that the modules are inserted

 

properly. Tighten the modules' screws. Power ON the unit.

 

Using an ASCII terminal port, check for a fault indication in the

 

Diagnostics window. If there is a fault, inform a qualified ARC-101

 

technician.

 

 

Data transmission difficulties

Ensure that the plugged-in modules are compatible with the protocol

 

used (media, data rate).

 

Check the module's software configuration in the Configuration window.

 

Verify that the SYNC indicator is ON. If it is OFF (indicating a fault in the

 

data reception link), run diagnostics on the remote unit from which data

 

is being transmitted to the ARC-101. If it is BLINKING (indicating a fault

 

in the data transmission link), run diagnostics on the remote unit, or

 

implement a loop on the ARC-101 module, and verify that the

 

SYNC LED is ON.

3-2

Operating Procedure

Image 32
Contents ARC-101 RAD data communications Headquarters US East US WestPage Warranty Safety Warnings Safety Status PortsRegulatory Information Safety Supplementary InformationContents Operation List of Figures List of Tables Chapter Introduction General DescriptionARC-101 Features Interfaces SupportedTraffic Management Loopback Mode Specifications RM-2 Ordering ARC-101/#RM-1 Introduction Specifications General UnpackingSite Requirements Rack Mounting InstructionsInstallation Cable ConnectionsTwo Units ATM Connection Control PortChanging Control Port Mode PinoutAC Power Connection GroundingModule Characteristics ARC-101 ModulesSC13M/155 Module ST13S/155 ModuleST13L/155 Module CX/BNC/155 ModuleUTP/155 Module 12 UTP/155 Module Front PanelE3 Module T3 ModuleE1 and E1/LTU ModulesInserting Removing Modules Inserting Modules Removing ModulesJumper Settings For E1 and E1/LTUJumper Settings for T3 17 T3 Jumper LocationsInstallation Chapter Operation Name DescriptionOperating Procedure ARC-101 Block Diagram Operation ARC Menu Accessing, Using and Exiting Monitor ModeIntroduction Configuration Window Screen ExplanationsGeneral Information Window General InformationConfiguration SystemParameters ALL Changes will be SAVED. are YOU SURE? Y/NRight/Left Module Configuration Left ModuleAscii Terminal Configuration Ascii Terminal ConfigurationPerformance Monitoring Window Diagnostics WindowDiagnostics Link Status SONET/SDH Link Status Window SLMT3 Link Status Window Errors/Alarms displayed in Plcp Mode LOS LOC OOF AIS RDI BIP FebeATM Traffic ATM StatusE3 Link Status Window E1 Link Status WindowCounter precision is 1/10,000 Software Management Performance Monitoring Window