RAD Data comm ASM-20 operation manual Physical Description, Front Panel

Page 16

ASM-20Installation and Operation Manual

Chapter 1. Introduction

 

 

Connection to an RS-449/V.36 interface is accomplished via the RS-530 interface (see Appendix A, Ethernet Interface). ASM-20 incorporates a built-in Bit Error Rate Tester (BERT). The internal BERT allows complete testing of both modems and the line without external test equipment. A front panel switch generates a pseudo-random test pattern (511-bit, according to ITU/V.52) for testing end-to-end connectivity. The ERROR LED will flash when a bit error is encountered.

 

1.2 Physical Description

 

ASM-20 is available as a desk-top unit or a rack-mountable card for a

 

19" rack. The rack can carry up to 14 ASM-20 cards which provide a 25-pin

 

D-type connection to the digital interface. Optional interface adapters for

 

V.35, X.21, G703 and ETH are available. The ASM-20/R card can detect and

 

indicate power failure on the remote ASM-20 standalone unit. The RPF LED

 

will light up if remote power failure occurs.

Front Panel

Figure 1-4shows a general view of ASM-20.

 

Figure 1-4 ASM-20, General View

LEDs

All controls (push button and LED indicators are located on the ASM-20 front

 

panel (see Figure 1-4). A description of the front panel can be found in

 

Controls and Indicators in Chapter 3.

Jumpers

A description of the jumpers can be found in Setting Internal Jumpers and

 

Switches in Chapter 2. See Table 2-1 and Figure 2-3.

Rear Panel

Figure 1-5shows an example of an ASM-20 rear panel. A description of the

 

rear panel can be found in Electrical Installation in Chapter 2.

 

The line and interface connectors are located on the rear panel of ASM-20

 

(see Figure 1-5).

Physical Description

1-3

Image 16
Contents ASM-20 RAD data communications Headquarters US East US WestPage Warranty Safety Warnings Ports Safety StatusRegulatory Information Safety Supplementary InformationInstalling and Operating ASM-20 Adjust the jumpers. See , Installation and SetupQuick-Start Guide INT or EXT and the other modem RCV LBTPreface Conventions Contents Troubleshooting and Diagnostics List of Figures List of Tables Overview Chapter IntroductionApplications DTE interface Following DTE interface options are availablePhysical Description Front PanelCDD conditional diphase modulation technique Functional DescriptionAsync to Sync Converter Unloaded twisted pair 19 to 26 AWG Technical SpecificationsRange See Table Level Digital Interface Diagnostics Timing ElementsPower Red Bit errors Err YellowPower Supply 115 or 230 V 10% 47 to 63 Hz 5W Weight 290 gm / 10.1 ozApproximate Range Baud 19 AWG 22 AWG 24 AWG 26 AWG RateIntroduction Technical Specifications Introduction Chapter Installation and SetupSite Preparation and Prerequisites Mechanical Installation Package ContentsElectrical Installation Strap Selection Setting Internal Jumpers Switches ASM-20 X.21 Rear PanelPCB Layout Diagram X.21, one of the modems should be set to RCV clockASM-20 Strap Selection Settings Jumper Function Possible Factory Switch Identity SettingsStart Bit Data Bits Parity Stop Bit No. of Bits Power Connection Installation and Setup Electrical Installation Controls and Indicators Chapter OperationGeneral ASM-20Control and Indicator Functions Name Type FunctionPower On Procedure Operating InstructionsPower Off Activation of Tests Operational Jumper Switch ChangesProcedure Chapter Troubleshooting Diagnostics Frequently Asked QuestionsDifferences in Versions ASM-20 ASM-20-2Loop Tests Procedure Bit Error Rate Tester BertBert Using Loops Modem Self Test Local Test Analog LoopbackCommunication Link Tests Remote Digital LoopbackLocal Digital Loopback Remote ASM-20 in Digital LoopbackChapter Card Cage Version ASM-MN-214 Card CageASM-20/R Card Version ASM-MN-214 Rear PanelPower Supply AC Supply 100, 115 or 230 VAC DC Supply -48 VDCPower Supply with Redundancy ASM-MN-214 Front PanelInstallation Card Cage Version Installation Appendix a Ethernet Interface DescriptionIR-ETH Connector Options Signal Pin DB-25 RJ-45Installation and Operation Ethernet Bridge SpecificationsGeneral Other devices do not OptionTable A-3 IR-ETH Bridge LED Indicators Description Location Color NameAppendix A. Ethernet Interface Installation and Operation Appendix B IR-G.703 Codirectional Interface 64 kbps General DescriptionEXT Mode Figure B-2 Location of JP1 on the IR-G.703 Interface ModuleModem B INT/RCV ModeOdem a Odem B Page Appendix C IR-X.21B Interface Module Figure C-1 Typical ASM-20 X.21 ApplicationInterface module $87,21 25&21,18 Table C-1 IR-X.21B DB-15 RS-422 Connector Pin AssignmentPin Function IR-X.21B Interface Module PositionFigure C-4 EXT Mode Timing Block Appendix D DTE Interface Connectors Pin Circuit FunctionRTS Signal General 13/4/99 Appendix E Connection to RS-422 Signal Function RS-449 RS-422/423 EIA PinsPin Circuit Appendix E. Connection to RS-422 Appendix F Unit Case Assembly Installation of the Unit Case into a 19 RackInstallation of a Single Unit Unit CaseInstallation of Two Units Figure F-1 Installation of a Single UnitAppendix F. Unit Case Assembly Figure F-3 Installation of Two Units