RAD Data comm ASM-20 operation manual Control and Indicator Functions, Name Type Function

Page 33

Chapter 3. Operation

ASM-20Installation and Operation Manual

 

 

E

P W R

RT S

TD

D C D

TE S T E R R

R P F

D IG

A N A

PATT

ASM - 20

1

2

3

4

5

7

A

B

C

D

 

 

Figure 3-2 ASM-20R Front Panel

 

 

Table 3-1

Control and Indicator Functions

Item

Name

Type

Function

 

 

 

 

A

DIG

Pushbutton

The Digital Loopback switch causes the local ASM-20 to loop

 

 

 

received data and clock back to its transmitter. Data Set Ready

 

 

 

will turn off (see Figure 4-5).

 

 

 

 

B

ANA

Pushbutton

The Analog Loopback (V.54 Loop 3) switch causes the local

 

 

 

ASM-20 to loop its transmitter output back to its receiver (see

 

 

 

Figure 4-3). This loopback may also be activated from the DTE

 

 

 

when DTE COMMAND ALB strap is set to EN.

 

 

 

 

C

REM

Pushbutton

The Remote Digital Loopback (V.54 Loop 2) switch causes the

 

 

 

remote ASM-20 to loop received data and clock to its

 

 

 

transmitter (see Figure 4-4). Data Set Ready will turn off. This

 

 

 

loopback may be also activated from the terminal when DTE

 

 

 

COMMAND RLB strap is set to RLB EN.

 

 

 

 

D

PATT

Pushbutton

The PATT switch causes the ASM-20 to send and receive a 511

 

 

 

test pattern. If errors are encountered,, the ERROR LED is ON

 

 

 

or blinks. Receive Data and Clear to Send will turn off.

Note: The CARRIER jumper should be set to ON; if set to

CNTRL, the RTS signal must be high.

3-2 Controls and Indicators

Image 33
Contents RAD data communications Headquarters US East US West ASM-20Page Warranty Ports Safety Status Safety WarningsRegulatory Information Supplementary Information SafetyAdjust the jumpers. See , Installation and Setup Installing and Operating ASM-20Quick-Start Guide INT or EXT and the other modem RCV LBTPreface Conventions Contents Troubleshooting and Diagnostics List of Figures List of Tables Chapter Introduction OverviewApplications Following DTE interface options are available DTE interfaceFront Panel Physical DescriptionFunctional Description CDD conditional diphase modulation techniqueAsync to Sync Converter Technical Specifications Unloaded twisted pair 19 to 26 AWGRange See Table Level Timing Elements Digital Interface DiagnosticsRed Bit errors Err Yellow PowerPower Supply 115 or 230 V 10% 47 to 63 Hz 5W Weight 290 gm / 10.1 ozBaud 19 AWG 22 AWG 24 AWG 26 AWG Rate Approximate RangeIntroduction Technical Specifications Chapter Installation and Setup IntroductionSite Preparation and Prerequisites Package Contents Mechanical InstallationElectrical Installation ASM-20 X.21 Rear Panel Strap Selection Setting Internal Jumpers SwitchesX.21, one of the modems should be set to RCV clock PCB Layout DiagramJumper Function Possible Factory Switch Identity Settings ASM-20 Strap Selection SettingsStart Bit Data Bits Parity Stop Bit No. of Bits Power Connection Installation and Setup Electrical Installation Chapter Operation Controls and IndicatorsGeneral ASM-20Name Type Function Control and Indicator FunctionsOperating Instructions Power On ProcedureActivation of Tests Operational Jumper Switch Changes Power OffProcedure Frequently Asked Questions Chapter Troubleshooting DiagnosticsDifferences in Versions ASM-20 ASM-20-2Bit Error Rate Tester Bert Loop Tests ProcedureBert Using Loops Local Test Analog Loopback Modem Self TestRemote Digital Loopback Communication Link TestsRemote ASM-20 in Digital Loopback Local Digital LoopbackASM-MN-214 Card Cage Chapter Card Cage VersionASM-MN-214 Rear Panel ASM-20/R Card VersionAC Supply 100, 115 or 230 VAC DC Supply -48 VDC Power SupplyASM-MN-214 Front Panel Power Supply with RedundancyInstallation Card Cage Version Installation Description Appendix a Ethernet InterfaceSignal Pin DB-25 RJ-45 IR-ETH Connector OptionsEthernet Bridge Specifications Installation and OperationGeneral Option Other devices do notDescription Location Color Name Table A-3 IR-ETH Bridge LED IndicatorsAppendix A. Ethernet Interface Installation and Operation General Description Appendix B IR-G.703 Codirectional Interface 64 kbpsFigure B-2 Location of JP1 on the IR-G.703 Interface Module EXT ModeINT/RCV Mode Modem BOdem a Odem B Page Figure C-1 Typical ASM-20 X.21 Application Appendix C IR-X.21B Interface ModuleTable C-1 IR-X.21B DB-15 RS-422 Connector Pin Assignment Interface module $87,21 25&21,18Pin Function Position IR-X.21B Interface ModuleFigure C-4 EXT Mode Timing Block Pin Circuit Function Appendix D DTE Interface ConnectorsRTS Signal General 13/4/99 Signal Function RS-449 RS-422/423 EIA Pins Appendix E Connection to RS-422Pin Circuit Appendix E. Connection to RS-422 Installation of the Unit Case into a 19 Rack Appendix F Unit Case AssemblyInstallation of a Single Unit Unit CaseFigure F-1 Installation of a Single Unit Installation of Two UnitsAppendix F. Unit Case Assembly Figure F-3 Installation of Two Units