RAD Data comm ASM-20 operation manual Start Bit Data Bits Parity Stop Bit No. of Bits

Page 29

Chapter 2. Installation and SetupASM-20Installation and Operation Manual

Table 2-1 ASM-20 Strap Selection Settings (Cont.)

Jumper and

Function

Possible

Factory

Switch Identity

 

Settings

Setting

 

 

 

 

SW2

Select character length in async mode

ASYNC LENGTH

(see Table 2-2for further explanation).

(3 dip switches)

 

S1

S2

No. Bits

S1 = OFF

OFF OFF

8

S2 = OFF

ON

OFF

9

 

OFF ON

10

 

ON ON

11

 

 

 

S3

 

S3 = ON

 

Selects the stop bit reduction rate to be used in

OFF 25%

 

 

async mode.

 

 

ON 12.5%

 

 

 

 

 

 

 

 

SW3

Selects the data rate.

Rate

 

Baud Rate (kbps)

 

0)

256 kbps

 

 

 

 

 

 

1)

192 kbps

 

 

 

2)

144 kbps

 

 

 

3)

128 kbps

 

 

 

4)

115.2 kbps $

 

 

 

5)

112 kbps

 

 

 

6)

96 kbps

 

 

 

7)

72 kbps

 

 

 

8)

64 kbps

64 kbps

 

 

9)

57.6 kbps $

 

 

 

A) 56 kbps

 

 

 

B) 48 kbps

 

 

 

C) 38.4 kbps $

 

 

 

D) 32 kbps

 

 

 

E) 28.8 kbps $

 

 

 

F) 19.2 kbps $$

 

 

 

 

 

 

$ Async baud rate

 

 

 

 

$$ Async/Sync baud rate

 

 

 

 

 

Table 2-2

Async Character Length Setting

 

 

 

 

 

 

Start Bit

Data Bits

Parity

Stop Bit

No. of Bits

 

 

 

 

 

1

5

NONE

2

8

 

 

 

 

 

1

6

NONE

1, 1.5, 2

8

 

 

 

 

9

 

 

 

 

 

1

6

ODD, EVEN

1, 1.5, 2

9

 

 

 

 

10

 

 

 

 

 

1

7

NONE

1, 1.5, 2

9

 

 

 

 

10

 

 

 

 

 

1

7

ODD, EVEN

1, 1.5, 2

10

 

 

 

 

11

 

 

 

 

 

1

8

NONE

1, 1.5, 2

10

 

 

 

 

11

 

 

 

 

 

1

8

ODD, EVEN

1, 1.5, 2

11

 

 

 

 

 

2-6 Electrical Installation

Image 29
Contents RAD data communications Headquarters US East US West ASM-20Page Warranty Ports Safety Status Safety WarningsRegulatory Information Supplementary Information SafetyAdjust the jumpers. See , Installation and Setup Installing and Operating ASM-20Quick-Start Guide INT or EXT and the other modem RCV LBTPreface Conventions Contents Troubleshooting and Diagnostics List of Figures List of Tables Applications Chapter IntroductionOverview Following DTE interface options are available DTE interfaceFront Panel Physical DescriptionFunctional Description CDD conditional diphase modulation techniqueAsync to Sync Converter Range See Table Level Technical SpecificationsUnloaded twisted pair 19 to 26 AWG Timing Elements Digital Interface DiagnosticsRed Bit errors Err Yellow PowerPower Supply 115 or 230 V 10% 47 to 63 Hz 5W Weight 290 gm / 10.1 ozBaud 19 AWG 22 AWG 24 AWG 26 AWG Rate Approximate RangeIntroduction Technical Specifications Site Preparation and Prerequisites Chapter Installation and SetupIntroduction Electrical Installation Package ContentsMechanical Installation ASM-20 X.21 Rear Panel Strap Selection Setting Internal Jumpers SwitchesX.21, one of the modems should be set to RCV clock PCB Layout DiagramJumper Function Possible Factory Switch Identity Settings ASM-20 Strap Selection SettingsStart Bit Data Bits Parity Stop Bit No. of Bits Power Connection Installation and Setup Electrical Installation Chapter Operation Controls and IndicatorsGeneral ASM-20Name Type Function Control and Indicator FunctionsOperating Instructions Power On ProcedureProcedure Activation of Tests Operational Jumper Switch ChangesPower Off Frequently Asked Questions Chapter Troubleshooting DiagnosticsDifferences in Versions ASM-20 ASM-20-2Bit Error Rate Tester Bert Loop Tests ProcedureBert Using Loops Local Test Analog Loopback Modem Self TestRemote Digital Loopback Communication Link TestsRemote ASM-20 in Digital Loopback Local Digital LoopbackASM-MN-214 Card Cage Chapter Card Cage VersionASM-MN-214 Rear Panel ASM-20/R Card VersionAC Supply 100, 115 or 230 VAC DC Supply -48 VDC Power SupplyASM-MN-214 Front Panel Power Supply with RedundancyInstallation Card Cage Version Installation Description Appendix a Ethernet InterfaceSignal Pin DB-25 RJ-45 IR-ETH Connector OptionsGeneral Ethernet Bridge SpecificationsInstallation and Operation Option Other devices do notDescription Location Color Name Table A-3 IR-ETH Bridge LED IndicatorsAppendix A. Ethernet Interface Installation and Operation General Description Appendix B IR-G.703 Codirectional Interface 64 kbpsFigure B-2 Location of JP1 on the IR-G.703 Interface Module EXT ModeOdem a Odem B INT/RCV ModeModem B Page Figure C-1 Typical ASM-20 X.21 Application Appendix C IR-X.21B Interface ModulePin Function Table C-1 IR-X.21B DB-15 RS-422 Connector Pin AssignmentInterface module $87,21 25&21,18 Position IR-X.21B Interface ModuleFigure C-4 EXT Mode Timing Block Pin Circuit Function Appendix D DTE Interface ConnectorsRTS Signal General 13/4/99 Pin Circuit Signal Function RS-449 RS-422/423 EIA PinsAppendix E Connection to RS-422 Appendix E. Connection to RS-422 Installation of the Unit Case into a 19 Rack Appendix F Unit Case AssemblyInstallation of a Single Unit Unit CaseFigure F-1 Installation of a Single Unit Installation of Two UnitsAppendix F. Unit Case Assembly Figure F-3 Installation of Two Units