RAD Data comm operation manual ASM-20 Strap Selection Settings

Page 28

ASM-20Installation and Operation ManualChapter 2. Installation and Setup

Table 2-1 ASM-20 Strap Selection Settings

Jumper and

Function

Possible

Factory

Switch Identity

 

Settings

Setting

 

 

 

 

J1

Prevents activation of remote V.54 loops.

EN

EN

V54 DIS

 

DIS

 

 

 

 

 

J2

Selects the transmit carrier mode. When ON,

ON

ON

CARRIER

transmit carrier is constantly ON. When CNTRL,

CNTRL

 

 

transmit carrier is ON only when RTS is High. In

 

 

 

X.21, RTS is replaced by the CONTROL signal.

 

 

 

 

 

 

J3

Selects the transmit timing signal from either:

INT

INT

XMT CLK

internal clock, external clock or receive clock and

EXT

 

 

enables working in Asynchronous mode.

RCV

 

 

 

ASY

 

 

 

 

 

J4

Selects the delay between RTS and CTS.

0

 

RTS-CTS

 

9

9 msec

DLY (ms)

 

70

 

 

 

 

 

J6

Enables activation of DIG, ANA and REM

ON

ON

SW. EN.

loopbacks via the front panel push buttons.

OFF

 

 

 

 

 

J7

Enables Remote Loopback command from the

EN

EN

RLB DTE

DTE.

DIS

 

 

 

 

 

J8

Enables Analog Loopback command from the

EN

EN

ALB DTE

DTE.

DIS

 

 

 

 

 

J9

Selects the receiver sensitivity level required.

LOW

LOW

RCV LVL

 

HIGH

 

 

 

 

 

J10

Selects receive line impedance.

150Ω

150 Ω

RCV IMP

 

HIGH

 

 

 

 

 

J11

Enables the Remote Power Failure feature.

ON

ON

RPF*

 

OFF

 

 

 

 

 

J12

Selects the transmit output level to the line.

0 dBm

0 dBm

XMT LVL

 

-6 dBm

 

 

 

 

 

J13

Selects the transmit line impedance.

150Ω

150Ω

XMT IMP

 

LOW

 

 

 

 

 

J14

The CON setting connects Signal Ground to

DIS

 

CHASS

Chassis Ground. The DIS setting disconnects

CON

CON

 

them.

 

 

 

 

 

 

*Only for standalone option

Electrical Installation

2-5

Image 28
Contents ASM-20 RAD data communications Headquarters US East US WestPage Warranty Safety Warnings Ports Safety StatusRegulatory Information Safety Supplementary InformationInstalling and Operating ASM-20 Adjust the jumpers. See , Installation and SetupQuick-Start Guide INT or EXT and the other modem RCV LBTPreface Conventions Contents Troubleshooting and Diagnostics List of Figures List of Tables Overview Chapter IntroductionApplications DTE interface Following DTE interface options are availablePhysical Description Front PanelCDD conditional diphase modulation technique Functional DescriptionAsync to Sync Converter Unloaded twisted pair 19 to 26 AWG Technical SpecificationsRange See Table Level Digital Interface Diagnostics Timing ElementsPower Red Bit errors Err YellowPower Supply 115 or 230 V 10% 47 to 63 Hz 5W Weight 290 gm / 10.1 ozApproximate Range Baud 19 AWG 22 AWG 24 AWG 26 AWG RateIntroduction Technical Specifications Introduction Chapter Installation and SetupSite Preparation and Prerequisites Mechanical Installation Package ContentsElectrical Installation Strap Selection Setting Internal Jumpers Switches ASM-20 X.21 Rear PanelPCB Layout Diagram X.21, one of the modems should be set to RCV clockASM-20 Strap Selection Settings Jumper Function Possible Factory Switch Identity SettingsStart Bit Data Bits Parity Stop Bit No. of Bits Power Connection Installation and Setup Electrical Installation Controls and Indicators Chapter OperationGeneral ASM-20Control and Indicator Functions Name Type FunctionPower On Procedure Operating InstructionsPower Off Activation of Tests Operational Jumper Switch ChangesProcedure Chapter Troubleshooting Diagnostics Frequently Asked QuestionsDifferences in Versions ASM-20 ASM-20-2Loop Tests Procedure Bit Error Rate Tester BertBert Using Loops Modem Self Test Local Test Analog LoopbackCommunication Link Tests Remote Digital LoopbackLocal Digital Loopback Remote ASM-20 in Digital LoopbackChapter Card Cage Version ASM-MN-214 Card CageASM-20/R Card Version ASM-MN-214 Rear PanelPower Supply AC Supply 100, 115 or 230 VAC DC Supply -48 VDCPower Supply with Redundancy ASM-MN-214 Front PanelInstallation Card Cage Version Installation Appendix a Ethernet Interface DescriptionIR-ETH Connector Options Signal Pin DB-25 RJ-45Installation and Operation Ethernet Bridge SpecificationsGeneral Other devices do not OptionTable A-3 IR-ETH Bridge LED Indicators Description Location Color NameAppendix A. Ethernet Interface Installation and Operation Appendix B IR-G.703 Codirectional Interface 64 kbps General DescriptionEXT Mode Figure B-2 Location of JP1 on the IR-G.703 Interface ModuleModem B INT/RCV ModeOdem a Odem B Page Appendix C IR-X.21B Interface Module Figure C-1 Typical ASM-20 X.21 ApplicationInterface module $87,21 25&21,18 Table C-1 IR-X.21B DB-15 RS-422 Connector Pin AssignmentPin Function IR-X.21B Interface Module PositionFigure C-4 EXT Mode Timing Block Appendix D DTE Interface Connectors Pin Circuit FunctionRTS Signal General 13/4/99 Appendix E Connection to RS-422 Signal Function RS-449 RS-422/423 EIA PinsPin Circuit Appendix E. Connection to RS-422 Appendix F Unit Case Assembly Installation of the Unit Case into a 19 RackInstallation of a Single Unit Unit CaseInstallation of Two Units Figure F-1 Installation of a Single UnitAppendix F. Unit Case Assembly Figure F-3 Installation of Two Units