Appendix
Setting items of the network
Item | Outline | |
IP Address | The IP address of the Presenter. | |
| Specifies the value allocated by the administrator of the network in use. | |
| Factory set to 192.168.0.100. | |
|
| |
Subnet mask | The mask value for separating the network address from the host address. | |
| Used in combination with the IP address to specify the network to which this Presenter | |
| belongs.Specifies the value allocated by the administrator of the network in use. | |
| Factory set to 255.255.255.0. | |
|
| |
Default | Specifies the IP address of the router when this Presenter is used on the network equipped with | |
Gateway | a router. For the IP address of the router, ask the administrator of the network to in use. Factory | |
set to 0.0.0.0. Set to 0.0.0.0. when using the Presenter on the network equipped with no router. | ||
| ||
root password | The password for setting up the network and using telnet. Not factory set. | |
| Should preferably be set for the security purpose. | |
user password | The password for setting up the FTP client to enable the use of the image transfer button | |
| [IMAGE TRANSFER] and for using the FTP server function. Not factory set. |
Setting items of the FTP client
Item | Outline |
IMAGE TRANSFER | Specifies Enable/Disable of the image transfer button [IMAGE TRANSFER]. Factory set to Disable. |
The IP address / the | Specifies the IP address of the destination host to save. |
image receiving server | Factory set to 0.0.0.0. |
The port number / the | Specifies the port number used by the FTP server in operation at the destination host to save. |
image receiving server | Normally, no need to be changed. Factory set to 21. |
The account / the | Specifies the account name used for connection to the destination host to save. |
image receiving server | Factory set to anonymous. |
The password / the | Specifies the password of the above account. |
image receiving server | Not factory set. |
Passive mode | Specifies which mode is used for file transfer, the passive mode or active mode. |
| When the port is limited by firewall, etc., use the passive mode. For whether the passive mode |
| should be used or not, ask the administrator of the network in use. Factory set to no use. |
|
|
Destination | Specifies the destination directory to save the image file. Specifies the |
directory to save | of the assigned account. Not factory set. (The root directory has been specified.) |
|
|
Image size | Specifies the size of image to be saved from among SXGA, VGA and QVGA. The image sizes |
| are 1280X1024 for SXGA, 640X512 for VGA, and 320X256 for QVGA. |
| Factory set to SXGA. |
|
|
File name of | Specifies the name of the file to be saved. Automatically adds the extension [.jpg] to the file |
image | name. Since any file under the same name in the saving destination is overwritten, specify a |
| different file name from the existing file names. Factory set to [img]. |
|
|
Add sequential | Specifies whether Yes/No to the addition of sequential number to the file name. When [Yes] is |
number to file | specified, the image is saved under the file name specified for the image with the sequential |
name | number added (e.g., img000000.jpg, img000001.jpg) each time the file is saved. When the |
| power supply to the Presenter is turned ON or the FTP client settings are changed, the |
| sequential number to be added to the file name is reset to the number specified for the star |
| number of sequence. Factory set to Yes. |
Start number of | Specifies the start number of sequence when the sequential number is add to the file name. |
sequence | Factory set to [0]. |
End number of | Specifies the end number of sequence when the sequential number is added to the file name. |
sequence | When the sequential number reaches the end number, the sequential number returns to the start |
| number of sequence. Then, if there is a file already saved with the start number of sequence, |
| that file will overwritten when the new file is saved. Therefore, the end number of sequence |
| should preferably be larger. Factory set to 999. |
|
|
- 44 -