Chapter 3: Installation and Initial Setup

12. See the Port x ID Remap screen.

a. To access this screen, click the “Next” button or click the “Port x ID Remap” link on the left side of the screen. b. This screen allows you to set Modbus Slave ID Remap settings.

Figure 3-25. Port ID Remap screen.

c. The first box in line is the start of the remap range on the serial port you want to remap. Valid value range is from 1 to 247. d. The second box in line is the last serial port of that range. Valid value range is from 1 to 247.

e. The third box in line is the starting ID of a range to remap to. Valid value range is from 1 to 247.

f. The fourth box in line is auto filled-in based on the range filled in the first 3 boxes. Valid value range is from 1 to 247. g. Save settings by clicking the “Save” button.

13. See the Modbus ID Routing screen.

a. To access this screen, click the “Next” button or click the “Modbus ID Routing” Link on the left side of the screen. b. This screen allows you to set the Modbus Slave ID routing.

724-746-5500 blackbox.com

Page 29

Image 29
Contents Modbus Hardened Serial Server Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Specifications SpecificationsSpecifications Dimensional Diagrams Overview FeaturesOverview Introduction What‘s IncludedLES431A front and back panels LES431A components Modbus Hardened Serial Server Configuration SoftwareInstallation and Initial Setup Connecting the Power Supply Installation and Initial Setup1 RS-232 2 RS-422Modbus Hardened Serial Server Configuration Connections Connecting Modbus Hardened Serial Servers to a NetworkModbus License Acceptance Screen Installation and Initial Setup Software Installing screen 10. Installation Complete screen Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup See the General Settings screen in Figure Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup Installation and Initial Setup 29. Type IP Address 31. Web properties screen Installation and Initial Setup Null-modem Cable Modbus Hardened Serial Server LES431A 35. Serial Port Selection 36. Direct IP Connection Reloading Factory DefaultsDownloading Firmware Files Upgrading the Modbus Hardened Serial Server FirmwareUpgrading the Modbus Hardened Serial Server Firmware Uploading the Firmware to the Modbus Hardened Serial Server Testing a Modbus Hardened Serial Server Connection DiagnosticsDiagnostics Testing a Modbus Hardened Serial Server connection Ethernet Master and Serial Slaves Application ExamplesApplication Examples Application Examples Application Examples Modbus ID routing Modbus priority Port 1 Modbus Serial and Ethernet Masters, Serial and Ethernet SlavesModbus Slave ID routing 11. Port 1 Serial Serial Masters, IP Slaves12. Port 1 Modbus Identical Production Lines Identical Hard-Coded SlavesHints and Tips Modbus HelpModbus Help Modbus ASCII/RTU Basics Appendix A. Default Modbus Hardened Serial Server Settings Appendix a Default Modbus Hardened Serial Server SettingsTerminal Block Appendix B Connector PinoutsAppendix B. Connector Pinouts DB9 M Connector Standard Ethernet Cable RJ-45 Pinout Appendix C. Glossary Appendix C GlossaryBlackbox.com Blackbox.com Blackbox.com Black Box Tech Support FREE! Live /7