Maxtor 91280D5, 91024D4 Power Requirements, Power Mode Definitions, EPA Energy Star Compliance

Page 20

PRODUCTSPECIFICATIONS

Power Requirements

MODE

12V ± 8%

5V ± 10%

POWER

 

 

 

 

Spin-up (peak)

2900 mA

360 mA

36.6 W

 

 

 

 

Seek (avg)

780 mA

335 mA

11.1 W

 

 

 

 

Read/Write (avg)

310 mA

390 mA

5.7 W

 

 

 

 

Idle (avg)

305 mA

320 mA

5.3 W

 

 

 

 

Standby (avg)

20 mA

165 mA

1.1 W

 

 

 

 

Sleep (avg)

20 mA

55 mA

0.52 W

 

 

 

 

Power Mode Definitions

Spin-up

The drive is spinning up following initial application of power and has not yet reached full speed.

Seek

A random access operation by the disk drive.

Read/Write

Data is being read from or written to the drive.

Idle

The drive is spinning, the actuator is parked and powered off and all other circuitry is powered on. The drive is capable of responding to read commands within 40 ms.

Standby

The spin motor is not spinning. The drive will leave this mode upon receipt of a command that requires disk access. The time-out value for this mode is programmable. The buffer is active to accept write data.

Sleep

This is the lowest power state – with the interface set to inactive. A software or hardware reset is required to return the drive to the Standby state.

EPA Energy Star Compliance

Maxtor Corporation supports the goals of the U.S. Environmental Protection Agency’s Energy Star program to reduce the electrical power consumption of computer equipment.

Environmental Limits

PARAMETER

OPERATING

 

NON-OPERATING/STORAGE

 

 

 

 

Temperature

5° C to 55° C

 

low temperature (-40° C)

 

 

 

high temperature (71° C) per MIL-STD-810E, method 501.3,

 

 

 

climatic category; hot-induced conditions.

Thermal Gradient

 

25° C per hour (maximum)

 

 

 

 

Relative Humidity

 

5% to 95% (non-condensing)

 

 

 

 

Wet Bulb

 

 

27° C (maximum)

 

 

 

 

Altitude

-200 to 10,000 feet

 

-200 to 40,000 feet

 

 

 

 

Acoustic Noise (Idle mode)

3.5 bel average sound power

 

 

 

(per ISO 7779, 10 microphone)

 

 

 

 

 

 

3 – 3

Image 20
Contents HA RD Drive Produc T MA Nual DiamondMax Plus Revisions Manual No Before You Begin U T I O NContents Product Specifications Handling and InstallationAT Interface Description Host Software InterfaceGlossary Interface CommandsService and Support Figures Introduction Maxtor CorporationManual Organization AbbreviationsSignal Conventions ConventionsKey Words NumberingDiamondMax Plus 5120 Key Features Product DescriptionProduct Features Functional / InterfaceOn-the-Fly Hardware Error Correction Code ECC Logical Block AddressingDefect Management Zone DMZ Software ECC CorrectionRead-Ahead Mode Cache ManagementBuffer Segmentation Automatic Write Reallocation AWRMajor HDA Components Subsystem Configuration Jumper Location/ConfigurationCylinder Limitation Dual Drive SupportProduct Specifications Drive ConfigurationPerformance Specifications Models and CapacitiesPhysical Dimensions Parameter Standard MetricPower Requirements Power Mode DefinitionsEPA Energy Star Compliance Environmental LimitsReliability Specifications Shock and VibrationCanadian Emissions Statement Safety Regulatory ComplianceRadiated Electromagnetic Field Emissions EMC Compliance Handling and Installation Hard Drive Handling PrecautionsPre-formatted Drive Important NoticeUnpacking and Inspection Multi-pack Shipping ContainerRepacking Physical InstallationRecommended Mounting Configuration Before You Begin General Requirements Mounting Drive in System Attaching Interface Power Cables System Setup Hard Drive Preparation System Hangs During Boot Interface Connector SignalAT Interface Description Pin Description SummaryPIN Name Signal Name Signal Description Pin Description TableTiming Parameters Mode PIO TimingDMA Timing Ultra DMA Timing Timing Parameters all times in nanosecondsSustained Ultra DMA Data In Burst Device Terminating an Ultra DMA Data In Burst Initiating an Ultra DMA Data Out Burst Device Pausing an Ultra DMA Data Out Burst Device Terminating an Ultra DMA Data Out Burst Error Register Features RegisterHost Software Interface Task File RegistersSector Count Register Sector Number RegisterCylinder Number Registers Device/Head RegisterCommand Register Command Name Command Code Parameters Used SDH SummaryControl Diagnostic Registers Alternate Status RegisterDevice Control Register Digital Input RegisterInterrupt Handling Reset and Interrupt HandlingReset Handling Interface Commands Set Feature CommandsRead Verify Sectors Read CommandsRead Sectors Read DMA Read MultipleWrite Commands Set Multiple ModeWrite Sectors Write Verify SectorsWrite Multiple Write DMASet Feature Commands Set Features ModePower Mode Commands Sleep Mode Initialization Commands Identify Drive15-8 = PIO data transfer mode = Write Cache enabled Initialize Drive Parameters Format Track Seek, Format and Diagnostic CommandsExecute Drive Diagnostic A.R.T. Command Set Execute S.M.A.R.TService and Support Service PolicyNo Quibble Service SupportInternet MaxFax ServiceCustomer Service Glossary Direct Access Direct Memory AccessError Correction Code ECC Error FreeHard Error Head Disk Assembly HDAFile Allocation Table FAT Flux Changes PER InchPhase Locked Loop PLL Logical AddressLogical Block Addressing Logical SectorRandom Access Memory RAM Read Gate SignalRecoverable Error Sector Pulse SignalUN-CORRECTABLE Error Unrecoverable ErrorWrite Gate Signal THIN-FILM Media