Maxtor 94610H6, 93073H4, 96147H8, 91536H2, 92305H3 Power Mode Commands, Timer Value TIME-OUT Period

Page 48

INTERFACE COMMANDS

Power Mode Commands

Standby Immediate – 94h/E0h

Spin down and do not change time out value. This command will spin the drive down and cause the drive to enter the STANDBY MODE immediately. If the drive is already spun down, the spin down sequence is not executed.

Idle Immediate – 95h/E1h

Spin up and do not change time out value. This command will spin up the spin motor if the drive is spun down, and cause the drive to enter the IDLE MODE immediately. If the drive is already spinning, the spin up sequence is not executed. The actuator is parked and some circuits are powered off.

Standby – 96h/E2h

Spin down and change time out value. This command will spin the drive down and cause the drive to enter the STANDBY MODE immediately. If the drive is already spun down, the spin down sequence is not executed. A non-zero value placed in the sector count register will enable the Automatic Power Down sequence. The timer will begin counting down when the drive returns to the IDLE MODE. A value of zero placed in the sector count register will disable the Automatic Power Down sequence.

Idle – 97h/E3h

Spin up and change time out value. This command will spin-up the spin motor if the drive is spun-down.

If the drive is already spinning, the spin up sequence is not executed. A non-zero value placed in the Sector Count register will enable the Automatic Power Down sequence and their timer will begin counting down immediately. A value of zero placed in the Sector Count register will disable the Automatic Power Down sequence. The actuator is parked and some circuits are powered off.

TIMER VALUE

TIME-OUT PERIOD

0

Time-out disabled

1 - 240

(value * 5) seconds

241 - 251

((value - 240) * 30) minutes

252

21 minutes

253

Vendor unique period = 10 hours

254

Reserved

255

21 minutes, 15 seconds

Check Power Mode – 98h/E5h

This command returns a code in the Sector Count register that determines the current Power Mode status of the drive. If the drive is in, going to, or recovering from the STANDBY MODE the drive sets the Sector Count register to OOh. If the drive is in the IDLE MODE or ACTIVE MODE, the drive sets the Sector Count register to FFh.

Set Sleep Mode – 99h/E6h

This command will spin the drive down and cause the drive to enter the SLEEP MODE immediately. If the drive is already spun down, the spin down sequence is not executed.

Note: The only way to recover from SLEEP MODE is with a software reset or a hardware reset.

7 – 8

Image 48
Contents DiamondMax Before You Begin U T I O NContents Product Specifications AT Interface Description Service and Support Figures Introduction Maxtor CorporationManual Organization AbbreviationsConventions DiamondMax 60 Key Features Product DescriptionProduct Features Functional / InterfaceModel CYL MAX LBA CapacityCache Management Major HDA Components Subsystem Configuration Jumper Location / ConfigurationCylinder Limitation Jumper Description Product Specifications Drive ConfigurationPerformance Specifications Models and CapacitiesPhysical Dimensions maximum Parameter A N D a R D MetricPower Requirements Power Mode DefinitionsEPA Energy Star Compliance Environmental LimitsReliability Specifications Shock and VibrationParameter E R a T I N G Safety Regulatory Compliance EMC/EMIHandling and Installation Hard Drive Handling PrecautionsElectro-Static Discharge ESD Unpacking and Inspection Multi-pack Shipping ContainerPhysical Installation RepackingBefore You Begin Hook upSet up Start upInterface Connector PIN SignalAT Interface Description Pin Description SummaryPIN Name Signal Name Signal Description Pin Description TableTiming Parameters Mode PIO TimingDMA Timing Ultra DMA Timing Timing Parameters all times in nanosecondsSustained Ultra DMA Data In Burst Device Terminating an Ultra DMA Data In Burst Initiating an Ultra DMA Data Out Burst Device Pausing an Ultra DMA Data Out Burst Device Terminating an Ultra DMA Data Out Burst Host Software Interface Task File RegistersPort Read Write N T E N T S LBA Bits Command Register Summary R a M E T E R S U S E DControl Diagnostic Registers Reset and Interrupt Handling Interface Commands Read Commands Read DMA Write Commands Write Multiple Mode Set/Check Commands Value DescriptionEV E L Value M M a N D Power Mode Commands Timer Value TIME-OUT PeriodSleep Mode Initialization Commands Content Description15 -3 = reserved R D Content Description Initialize Drive Parameters Seek, Format and Diagnostic Commands Error Code DescriptionA.R.T. Command Set Key RegisterService and Support Service PolicyNo Quibble Service SupportFrom Dial Glossary BlockCorrectableerror Fetch Landingzoneorlzone Physicalsector Softerror