Maxtor 96147H8, 93073H4, 91536H2, 94610H6 Mode Set/Check Commands, Value Description, Ev E L

Page 46

INTERFACE COMMANDS

Mode Set/Check Commands

Set Features Mode

Enables or disables features supported by the drive. When the drive receives this command it:

1.Sets BSY,

2.Checks the contents of the Features register,

3.Clears BSY and

4.Generates an interrupt.

If the value of the register is not a feature supported by the drive, the command is aborted. The acceptable values in the Features register are defined as follows:

VALUE

DESCRIPTION

0 2 h

Enabled Write Cache

03h

Set Transfer Mode based on value in Sector Count register

05h

Enable Advanced Power Management

42h

Enable Automatic Acoustic Management. The sector count register contains the

 

Automatic Acoustic Management level.

 

S E C T O R

L EV E L

 

F F h

Maxtor specific

 

FEh

Maximum performance

 

81h - FDh

Intermediate acoustic management levels

 

80h

Minimum acoustic emanation level

 

00h-7Fh

reserved

44h

Length of data appended on Read Long/Write Long commands specified in the

 

Identify Device information

55h

Disable Read Look-ahead feature

66h

Disable reverting to Power-on defaults

82h

Disable Write Cache

85h

Disable Advanced Power Management

AAh

Enable Read Look-ahead feature

BBh

4 bytes of Maxtor specific data appended on Read Long/Write Long commands

C2h

Disable Automatic Acoustic Management

C C h

Enable reverting to Power-on defaults

7 – 6

Image 46
Contents DiamondMax Before You Begin U T I O NContents Product Specifications AT Interface Description Service and Support Figures Manual Organization IntroductionMaxtor Corporation AbbreviationsConventions DiamondMax 60 Key Features Product DescriptionModel CYL Product FeaturesFunctional / Interface MAX LBA CapacityCache Management Major HDA Components Jumper Location / Configuration Subsystem ConfigurationCylinder Limitation Jumper Description Performance Specifications Product SpecificationsDrive Configuration Models and CapacitiesPhysical Dimensions maximum Parameter A N D a R D MetricEPA Energy Star Compliance Power RequirementsPower Mode Definitions Environmental LimitsShock and Vibration Reliability SpecificationsParameter E R a T I N G Safety Regulatory Compliance EMC/EMIHard Drive Handling Precautions Handling and InstallationElectro-Static Discharge ESD Unpacking and Inspection Multi-pack Shipping ContainerPhysical Installation RepackingBefore You Begin Hook upSet up Start upAT Interface Description Interface ConnectorPIN Signal Pin Description SummaryPIN Name Signal Name Signal Description Pin Description TableTiming Parameters Mode PIO TimingDMA Timing Ultra DMA Timing Timing Parameters all times in nanosecondsSustained Ultra DMA Data In Burst Device Terminating an Ultra DMA Data In Burst Initiating an Ultra DMA Data Out Burst Device Pausing an Ultra DMA Data Out Burst Device Terminating an Ultra DMA Data Out Burst Task File Registers Host Software InterfacePort Read Write N T E N T S LBA Bits Command Register Summary R a M E T E R S U S E DControl Diagnostic Registers Reset and Interrupt Handling Interface Commands Read Commands Read DMA Write Commands Write Multiple Value Description Mode Set/Check CommandsEV E L Value M M a N D Power Mode Commands Timer Value TIME-OUT PeriodSleep Mode Initialization Commands Content Description15 -3 = reserved R D Content Description Initialize Drive Parameters Seek, Format and Diagnostic Commands Error Code DescriptionA.R.T. Command Set Key RegisterNo Quibble Service Service and SupportService Policy SupportFrom Dial Glossary BlockCorrectableerror Fetch Landingzoneorlzone Physicalsector Softerror