Hand Held Products
IT4800, IT4X80
manual
User’s Guide, Quick Check 2D Print Quality Assessment
Error Correction Level ECL
Symbology
Dimension
Safety
Obtaining Factory Service
Using the Quick*View Software
Page 1
Quick Check 2D Print Quality Assessment
Applies to the following products: IT4410, IT4710, IT4600, IT4800, IT4X80
User’s Guide
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
Quick Check 2D Print Quality Assessment
User’s Guide
Disclaimer
Table of Contents
Chapter 1 - Introduction
Chapter 3 - Customer Support
Chapter 2 - Quick*View
Symbology
X-dimension
User Operation
Introduction
Reading Techniques
Symbology/Parameter Specifics
Full Report
2D PQA Reporting
Screening Report
This is a representative PDF417 symbol PQA from HHP
Identifying Symbol Content
A Data Safety Margin = 100% 0 Erasures & 0 Errors
PDF417 11 rows x 3 cols, 25 data & 8 chks ECL = 2 X roughly =
PDF417
2D Stacked / Multi-row
Excessive Print Shrinkage -43% of
where
In Screening modes, this parameter is reported as Useful Row Height is Too Short 1.5X when that is the case
1 is the Encoded Message
MicroPDF417
Aztec Code
2D Matrix
1 This is a representative Data Matrix symbol 2 PQA from HHP
Data Matrix
6 A Fixed Patterns 0 module errors
3 DATA MATRIX ECC200 24 x 24 modules in size
7 A Data Safety Margin = 100%
QR Code
1 This is a representative QR Code symbol 2 PQA from HHP
4 lists this symbols Mask Pattern and Error Correction Level
MaxiCode
Postnet and Planet Code
Postal Height-Modulated Bar Code Symbologies
7 A Ok Bar Widths = 0.022 in 8 A Ok Inter-Bar Gaps = 0.023 in
1 B15AJ6T 2 PQA from HHP
4-State Codes
3 4-STATEBritish 34 Bars, nominally from 38.5 to 42.3 mm. in Width
4 Bar Sequence ADHTATDAHDDAADADAADTHTADHHDATHTADH
Average Bar/Gap Width
Parameter Interpretation
Average Bar Height/Extension Height
Table 1 Dimensional Tolerances for the Various 4-State Bar
Bar Sequence
Data Safety Margin
Codeword Data and Check
Codeword Yield
Error Correction Level ECL
Error Correction/Error Correction Characters
Error Detection/Error Detection Characters
Encoded Message
Symbology
Module Errors
Print Growth Horizontal and Vertical
Row Height
X-dimension
Setting Up the Imager and the Quick*View Software
Installing Quick*View from the Web
Quick*View
Quick*View Demonstration Software Instructions
IT4600/4800/4X80
Temporary Quick*View Configuration
IT4410/4710
If Communication Cannot Be Established
Using the Quick*View Software
Scan Data Window
Customer Support
Obtaining Factory Service
North America
Latin America
North America/Canada
Technical Assistance
Asia
Page
QC2DPQA-UG Rev B
Related pages
Where can I find the administration instructions for
wag160n
?
Top
Page
Image
Contents