Hand Held Products
IT4600, IT4X80 Encoded Message, Error Correction/Error Correction Characters
Error Correction Level ECL
Symbology
Dimension
Safety
Obtaining Factory Service
Using the Quick*View Software
Page 22
Page 21
Page 23
Image 22
Page 21
Page 23
Contents
User’s Guide
Quick Check 2D Print Quality Assessment
Disclaimer
Chapter 1 - Introduction
Table of Contents
Symbology
Chapter 2 - Quick*View
Chapter 3 - Customer Support
X-dimension
User Operation
Introduction
Reading Techniques
Symbology/Parameter Specifics
Full Report
2D PQA Reporting
Screening Report
A Data Safety Margin = 100% 0 Erasures & 0 Errors
Identifying Symbol Content
This is a representative PDF417 symbol PQA from HHP
PDF417 11 rows x 3 cols, 25 data & 8 chks ECL = 2 X roughly =
PDF417
2D Stacked / Multi-row
Excessive Print Shrinkage -43% of
where
In Screening modes, this parameter is reported as Useful Row Height is Too Short 1.5X when that is the case
MicroPDF417
1 is the Encoded Message
2D Matrix
Aztec Code
6 A Fixed Patterns 0 module errors
Data Matrix
1 This is a representative Data Matrix symbol 2 PQA from HHP
3 DATA MATRIX ECC200 24 x 24 modules in size
7 A Data Safety Margin = 100%
QR Code
1 This is a representative QR Code symbol 2 PQA from HHP
MaxiCode
4 lists this symbols Mask Pattern and Error Correction Level
Postal Height-Modulated Bar Code Symbologies
Postnet and Planet Code
7 A Ok Bar Widths = 0.022 in 8 A Ok Inter-Bar Gaps = 0.023 in
3 4-STATEBritish 34 Bars, nominally from 38.5 to 42.3 mm. in Width
4-State Codes
1 B15AJ6T 2 PQA from HHP
4 Bar Sequence ADHTATDAHDDAADADAADTHTADHHDATHTADH
Average Bar Height/Extension Height
Parameter Interpretation
Average Bar/Gap Width
Table 1 Dimensional Tolerances for the Various 4-State Bar
Codeword Data and Check
Data Safety Margin
Bar Sequence
Codeword Yield
Error Detection/Error Detection Characters
Error Correction/Error Correction Characters
Error Correction Level ECL
Encoded Message
Print Growth Horizontal and Vertical
Module Errors
Symbology
Row Height
X-dimension
Quick*View
Installing Quick*View from the Web
Setting Up the Imager and the Quick*View Software
Quick*View Demonstration Software Instructions
IT4600/4800/4X80
Temporary Quick*View Configuration
IT4410/4710
Using the Quick*View Software
If Communication Cannot Be Established
Scan Data Window
North America
Obtaining Factory Service
Customer Support
Latin America
North America/Canada
Technical Assistance
Asia
Page
QC2DPQA-UG Rev B
Related pages
All Error page
Factory Default Settings for IOGear GCS932UB
Error for Ricoh SP 112
Database Connection Error 5051 error appears for Cisco Systems 5.0(1)
Changing Default Seitings for Ricoh FT6645
Default is True for HP AA-RW20A-TE
Error for Amstrad DDI-1
To change the default fax resolution for Brother MFC-253CW
Default value 32 nodes for Omron CS1W-RPT01
Setting Up a Default DMZ Server for NETGEAR WNR3500
Load Default for Audiovox FPE1078
What detergent should I use for my
hotpoint aquarius fdm550
?
Top
Page
Image
Contents