GD Commerce EDA-M150, EDA-M300, EDA-M350, EDA-M100, EDA-M200, Control and Booster Panels Windmill

Page 4

Page - 4 Windmill￿

5.0Using Windmill Software￿

5.1Defining a new system.￿

In order to create a new system click on the ‘create new’ button. The screen will display blank panel and￿ device information as shown in figure 5.2. To change the settings go to section 5.4￿

5.2 Loading from an earlier system stored on a disk￿

To load data from a previous system saved on disk click on the ‘Load from disk’ button.￿ A screen allowing you to select a file from the disk as shown in figure 5.1 is displayed.￿

To change the directory click on the appropriate buttons until the correct directory appears. To select the￿ desired file double click on the file name. Data will load and a screen similar to Figure 5.2 will be displayed.￿ To change settings proceed to section 5.4￿

Figure 5.1￿

5.3 Loading a system from the control panel.￿

Connect the front panel port of the control panel to the PC and click on ‘Load from panel’ button. A￿ progress bar will be displayed as the data is loaded. If this fails try pressing the internal reset button on the￿ processor board of the control panel and re-click the ‘load from panel’ button. Care should be taken to es-￿ tablish that the cause and effects are the same for the system in all panels as individual panels may oper-￿ ate different relays in an alarm or fault condition.This option is not available for the module port at present.￿

5.4 To Change Device Settings and/or Cause and Effects￿

Having created a new system, loaded the data from a disk or loaded data from a control panel the following￿ screen will be displayed. This screen may display information relating to the system being changed or be￿ blank if it is a new system. This screen is used to only display the settings. The screen details panel infor-￿ mation with the panel number pre-fixed with ‘P’ in the unit number column. Device information can be dis-￿ played by scrolling past the panel details. Panels 1 to 50 are displayed first. To scroll either click and hold￿ on the scroll bar or drag the drag bar to the appropriate position.￿

Figure 5.2￿

5.4.1 Change Device Settings￿

If you require to change device settings, then the screen needs to be positioned to display the device￿ number. Use the scroll bar or drag bar to position to selector to the devices.￿

Devices do not have the unit number prefixed with a ‘P’. Once positioned, double click on the parameter of￿ the appropriate device to be changed. Figure 5.3 will be displayed￿

If you require to change the cause and effects for a particular device number, select the device number and double click on the ‘Special’ row for the particular device. This will cause a screen as shown in figure 5.3 to￿ be displayed. If the device number is not correct then the up and down arrows can be used to reposition￿ the device number. It should be noted that any changes made prior to changing the device number will au-￿ tomatically be saved.￿

GD Systems

Image 4
Contents Hardware Specification 2 Windmill 3 Windmill 4 Windmill 5 Windmill 6 Windmill 7 Windmill 8 Windmill 9 Windmill 10 Windmill 11 Windmill 12 Windmill 13 Windmill 14 Windmill 15 Windmill 16 Windmill 17 Windmill Example M200 Download