Section 3 - Product Overview

Welcome to the world of conditioned power. Electrical power users from around the world benefit from the use of clean, quality power. That's why we developed the Conditioned Power Center (CPC). The CPC Series is a low- impedance power conditioner that provides high peak-load capability. You'll find that we've engineered these products to provide features not readily available as standard equipment on other three-phase power line conditioning products. The CPC series of products provide the functionality and flexibility that your business needs in a power quality solution-both now and in the future.

3.1 Product Purpose

The CPC is designed to eliminate high-frequency noise and high-voltage impulses (also known as spikes or surges) from the AC power that runs your electronic equipment. The power conditioner installs between the power source and the critical load. And because it is a three-phase device, the CPC provides protection for all transformer phases that power a large system. Sophisticated electronic systems contribute to the profitability of your business, and clean power is an essential element in their reliable operation. Each electronic system responds to power-quality problems differently, but properly protected systems benefit in a variety of ways. These benefits include fewer hardware failures, fewer "no problem found" service calls, less system downtime, higher manufacturing yield, better image quality and longer equipment life.

The CPC power conditioning series incorporates these three important power quality elements:

1.A low-impedance isolation transformer - The transformer is the "heart" of the power conditioning system. It provides unequaled protection against common mode (neutral to ground) disturbances and voltages. In addition, it provides all the criteria necessary to meet National Electrical Code 250-5d requirements for a "separately derived power source." The isolation transformer can be specified to accommodate the variety of electrical supply voltages and frequencies that are encountered throughout the world.

2.A low pass filter - The filter is responsible for removing normal mode (phase to neutral and phase to phase) noise components from the electrical power. These power disturbances are the ones that are caused by your system's "electrical neighbors" (i.e. elevators, copy machines, motors, HVAC equipment and even other computer systems).

3.A surge diverter - The surge diverter is part of the input (primary) circuit of the isolation transformer. This ensures that any voltage impulses generated within the facility (our outside of it due to occurrences like lightning and utility activities) do not interfere with the connected system. Although the surge diverter is designed to handle substantial energies, catastrophic events may occur, which damage one or more of the circuit’s protective elements. If such damage occurs, one or more of the TVSS Fault LEDs on the power conditioner’s front panel will illuminate. Consult Section 8.1.3 for instructions on how to proceed if a TVSS Fault LED illuminates.

Conditioned Power Center

11

Image 11
Contents CPC Series Conditioned Power Center Table of Contents Service and Support E a S E General Alerts and Labels SafetyAnsi Warning Notices Inherent HazardsWear protective gear before servicing internal parts Line Voltage Present With Machine Power OFFLockout/Tagout Safety InterlocksEmergency Contact Information Conformance with Applicable Laws and RegulationsProduct Liability Product Purpose Product OverviewOptional Features Standard FeaturesFeature Unpackaging PreparationPreparation Figure D Shipping Crate Disassembly 10 to 20 kVA Installation Fixed Input Circuit Breakers Outer Panel RemovalAlternate Conduit Landing Locations Main Input Circuit BreakerProgrammable Circuit Breakers Isolation TransformerFigure G Transformer Primary Voltage AdjustmentGrounding Output Voltage Fine AdjustmentFigure J Lockout/Tagout ProcedureModels With Optional Line Cord/Output Receptacles Input Power ConnectionsOutput Power Connections Operation Restoring For ServiceEnergizing the Power Conditioner Orderly Shutdown Energizing the LoadConditioned Power Center Seismic Anchorage Phase Loss/Low Voltage Detection and ProtectionOptions External EMOSemi S2-0200 Compliant EMO Input Power Conductor RestraintsSemi S2-0200 Certification Options Input Circuit Breaker Trips Troubleshooting/MaintenanceConditions Requiring Troubleshooting Source Circuit Breaker TripTvss Fault LEDs Illuminate Harmonic Filter Circuit Breaker Trips Out Routine MaintenanceProduct Warranty Service and SupportTechnical and Service Assistance Customer Service CPC Series Schematic SpecificationsGPI Series 2000 Standard EMO GPI Series 2000 Semi S2 EMO Important ALL Work to be Done By a Licensed Electrician Output Voltage Fine AdjustmentTitle Rev. Letter Rel. Date Next Rev. Level Document Revision HistorySM5505- Rev. a 03/01/2006, 2006 ETA Systems39