Section 3 - Product Overview

3.2 Standard Features

These include a “power on “ LED, TVSS Fault LEDs (one per phase), a lockout/tagout provision for the front panel input circuit breaker, safety interlocks, casters, and leveling feet. In addition, the CPC offers a range of options as described below.

3.3 Optional Features

Input line cord - This option is available on models 45 kVA and smaller.

Output receptacles - This option is available on all models. A range of different receptacle styles (each with over-current protection) may be added to the CPC power conditioner.

Distribution panels - This option is available only on models 85 kVA and larger. It provides a standard 42 circuit Square D panelboard from which the conditioner’s power may be distributed to individual branch circuits each with their own dedicated circuit breaker.

External EMO connector - This optional connector (if so equipped) is part of the power conditioner’s EMO (emergency machine off) circuit. It provides a point for connecting the power conditioner’s EMO circuit to an external control or the master EMO circuit of a computer room or similar facility. See Section 7.3

Seismic anchorage brackets - This options permits stabilization of the power conditioner in seismically active (earthquake prone) areas. Seismic design data is included in the specification sheet found in Section 10.

A 5th harmonic filter - The GPI Series 2000 may be ordered with an optional passive 5th harmonic filter. When so equipped, the CPC will significantly reduce the fifth odd order harmonic current regardless of origin (line or load). Passive harmonic filters tuned to other order harmonics are available special order. Consult the manufacturer for more information. If the CPC you are installing is equipped with an optional harmonic filter, consult Section 7.1 of this manual for complete information regarding it’s location and operation.

Zig-Zag transformer - This option is only available on models 85 kVA and larger. Special transformers with zigzag secondary windings for the elimination of harmonic currents are available as a special order from the manufacturer.

Basic metering/Power management package - All CPC models may be equipped with basic metering functions using Power Measurements Limited 6200 ION monitor. A full power management package is available on models 85 kVA and larger. This package uses a Power Measurements ION 7500 monitor and provides multiple functions including low voltage/phase loss/phase reversal detection and protection.

12

Conditioned Power Center

Image 12
Contents CPC Series Conditioned Power Center Table of Contents Service and Support E a S E General Safety Ansi Warning NoticesInherent Hazards Alerts and LabelsLine Voltage Present With Machine Power OFF Wear protective gear before servicing internal partsSafety Interlocks Lockout/TagoutConformance with Applicable Laws and Regulations Product LiabilityEmergency Contact Information Product Overview Product PurposeStandard Features Optional FeaturesFeature Preparation UnpackagingPreparation Figure D Shipping Crate Disassembly 10 to 20 kVA Installation Outer Panel Removal Alternate Conduit Landing LocationsMain Input Circuit Breaker Fixed Input Circuit BreakersIsolation Transformer Programmable Circuit BreakersTransformer Primary Voltage Adjustment Figure GOutput Voltage Fine Adjustment GroundingLockout/Tagout Procedure Figure JInput Power Connections Output Power ConnectionsModels With Optional Line Cord/Output Receptacles Restoring For Service Energizing the Power ConditionerOperation Energizing the Load Orderly ShutdownConditioned Power Center Phase Loss/Low Voltage Detection and Protection OptionsExternal EMO Seismic AnchorageInput Power Conductor Restraints Semi S2-0200 CertificationSemi S2-0200 Compliant EMO Options Troubleshooting/Maintenance Conditions Requiring TroubleshootingSource Circuit Breaker Trip Input Circuit Breaker TripsTvss Fault LEDs Illuminate Routine Maintenance Harmonic Filter Circuit Breaker Trips OutService and Support Technical and Service Assistance Customer ServiceProduct Warranty Specifications CPC Series SchematicGPI Series 2000 Standard EMO GPI Series 2000 Semi S2 EMO Output Voltage Fine Adjustment Important ALL Work to be Done By a Licensed ElectricianDocument Revision History Title Rev. Letter Rel. Date Next Rev. LevelSM5505- Rev. a 03/01/2006, 2006 ETA Systems39