ETA Systems SM5505 manual Feature

Page 13

Section 3 - Product Overview

complete monitoring of three phase voltages, currents, phase angles, power factor, demand, energy usage, event logs and more. If the CPC is equipped with the power management option, documentation prepared by Power Measurements Limited will accompany this manual. The table below illustrates a matrix of standard equipment and options for each model of GPI Series 2000.

3.4

Power On LED

TVSS Fault LEDs

EMO Pushbutton

Safety Interlocks

Lockout/Tagout

 

 

Input Line Cord

Output Receptacles

Distribution Panel

Ext. EMO Contacts

Seismic Anchorage

Harmonic Filter

Zig Zag Transformer

Basic Power Meter

Power Management

Feature

 

Leveling Feet

Matrix

Casters

S= Standard

O= Option

NA = Not Available

 

ABC10.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC15.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

 

ABC20.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC25.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC30.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC35.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC45.0-XDXY

S

S

O

S

S

S

S

O

O

NA

O

O

NA

NA

O

NA

ABC55.0-XDXY

S

S

O

S

S

S

S

NA

O

NA

O

O

NA

NA

O

NA

ABC65.0-XDXY

S

S

O

S

S

S

S

NA

O

NA

O

O

NA

NA

O

NA

ABC75.0-XDXY

S

S

O

S

S

S

S

NA

O

NA

O

O

NA

NA

O

NA

ABC85.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC100.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC125.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC150.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC175.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC200.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC230.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC250.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

ABC300.0-XDXY

S

S

O

S

S

S

S

NA

O

O

O

O

O

O

O

O

Conditioned Power Center

13

Image 13
Contents CPC Series Conditioned Power Center Table of Contents Service and Support E a S E General Ansi Warning Notices SafetyInherent Hazards Alerts and LabelsWear protective gear before servicing internal parts Line Voltage Present With Machine Power OFFLockout/Tagout Safety InterlocksProduct Liability Conformance with Applicable Laws and RegulationsEmergency Contact Information Product Purpose Product OverviewOptional Features Standard FeaturesFeature Unpackaging PreparationPreparation Figure D Shipping Crate Disassembly 10 to 20 kVA Installation Alternate Conduit Landing Locations Outer Panel RemovalMain Input Circuit Breaker Fixed Input Circuit BreakersProgrammable Circuit Breakers Isolation TransformerFigure G Transformer Primary Voltage AdjustmentGrounding Output Voltage Fine AdjustmentFigure J Lockout/Tagout ProcedureOutput Power Connections Input Power ConnectionsModels With Optional Line Cord/Output Receptacles Energizing the Power Conditioner Restoring For ServiceOperation Orderly Shutdown Energizing the LoadConditioned Power Center Options Phase Loss/Low Voltage Detection and ProtectionExternal EMO Seismic AnchorageSemi S2-0200 Certification Input Power Conductor RestraintsSemi S2-0200 Compliant EMO Options Conditions Requiring Troubleshooting Troubleshooting/MaintenanceSource Circuit Breaker Trip Input Circuit Breaker TripsTvss Fault LEDs Illuminate Harmonic Filter Circuit Breaker Trips Out Routine MaintenanceTechnical and Service Assistance Customer Service Service and SupportProduct Warranty CPC Series Schematic SpecificationsGPI Series 2000 Standard EMO GPI Series 2000 Semi S2 EMO Important ALL Work to be Done By a Licensed Electrician Output Voltage Fine AdjustmentTitle Rev. Letter Rel. Date Next Rev. Level Document Revision HistorySM5505- Rev. a 03/01/2006, 2006 ETA Systems39