2.2 CONFIGURATION
2.2.1 THE UNIVERSAL CONTROL OR COMMAND INTERPRETER
The Universal Control Card
Partitioning, port configuration, and diagnostic interface settings are done using the UniDiag PC software program. See the UniDiag Manual for instructions.
The Command Interpreter and the Matrix Control II are obsolete control cards for the NV3128 Router. Some instructions in this section apply only to older systems having these cards. These instructions have been retained for the benefit of customers who own older systems, but they are labeled "(OBSOLETE)" so that they are clearly identifiable.
2.2.2 PARTITIONING (OBSOLETE)
In systems using the newer Universal Control Card, partitioning is done with UniDiag. Older systems with the Command Interpreter are partitioned using the steps that follow.
The NV3128 consists of a single physical partition whose I/O dimension is the dimension of the routing switch, either 128x128 or 64x64. A shadow partition can be created to allow multidrop command hookups. By enabling the second ghost partition, I/O ports are addressed on either of two controller levels. A port addressed on the first level is configured for
NV3128 |