4.2 CIRCUIT OPERATION

The following discussion provides an overview of circuit operation for each of the circuit boards in the NV3128 Router frame. Because repair is done by replacing modules rather than repairing them, schematics and bills of material are not provided but may be requested from NVISION Technical Support.

4.2.1 I/O CONNECTOR INTERFACE

ASSY: EM0038-XX

RS-422A Machine Control data enters the NV3128 through PC- mounted D connectors on this passive connector interface assembly. On each D connector, an RC circuit AC couples the input shield terminal to ground. High density Metral connectors route the signals back to the active I/O and Command Interpreter Modules.

A bayonet style BNC connector receives the reference video input and loops it through to a second to facilitate daisy chain connections. Alarms and changeover connections arrive via Phoenix terminal blocks. Two spare BNCs are provided to accomodate possible future customization.

D connector sets carry command information from the external router control system, the diagnostic interface, and (on older frames) the parallel interface. The RS-232 and RS-422 interfaces are 9-pin D connectors, and the parallel interface is a 37-pin D. The primary control and parallel connectors have neighboring connectors that can be used for loop through. Note that the primary ports and their loop- thru connectors are not equivalent; you must connect the control system directly to the primary port.

4.2.2 SIGNAL BACKPLANE:

ASSY: 0039-XX

This captive, passive assembly mounts the high-density Metral connectors that carry the intra-frame signal traffic.

NV3128 RS-422A Machine-Control Data Routing Switch

4-5

Image 67
Contents Nvision PrintingHistory WarrantyStatement TechnicalSupport ImportantSafeguardsandNotices Page Page NorthAmericanPowerSupplyCords Tableofcontents Page Generalinformation NV3128 RS-422A Machine-Control Data Switch General GeneralinformationArchitecture Background NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch Solution Dynamic Ports Crosspointarchitecture NV3128 RS-422A Machine-Control Data Switch Physical Multidrop Command ChainsAncillary Equipment System Specifications1NV3128SPECIFICATIONS Installation NV3128 RS-422A Machine-Control Routing Switch Chapter TWO Installation NV3128 RS-422A Machine-Control Routing Switch Frame Installation Partitioning Obsolete Universal Control or Command InterpreterPartition DIP Switches Obsolete RE-INITIALIZE BIT/MULTIDROP Enable s7 SettingsInput Length s8-s5 Matrix Control II Jumpers ObsoleteRS-422A RS-232 Parallel Interface Obsolete Configuring the Diagnostic Interface ObsoleteJumper Enabled Disabled Reference Input Ground Obsolete Configuring the Reference InputCabling the NV3128 Cabling the Serial Command InterfacePIN RS-232 DCE VS. DTE Decision Obsolete RS232 ObsoletePIN Connector Implementing HOT Changeover Obsolete Adding a Redundant ControllerCabling Complete PC Diagnostic Interface UNIDIAG/NVUTILSRear Connections NEW Frame Rear Ections OLD Frame Rearconnections OLD Frame Nvtake PC-BASED Software Installation ObsoleteInstallation GeneralSample Install Session Software Installation Fixed DiskOperation from a Floppy Disk Hardware ConfigurationOperation NV3128 RS-422A Machine Control Data Routing Switch Connection Notes OperationsMultidrop Connection Rules POINT-TO-POINT Connection RulesComputer Utilities Obsolete F3 Change Router Level Operating Instructions Nvtake ObsoleteInvocation OperationsF1 Sending a Single Take F9 Build a Salvo Table F2 Send a Salvo F10 Load a Salvo from DiskF6 List Destinations Connected to a Source F5 Query Multiple ConnectionsOperation Operating Instructions Nvmap ObsoleteNV3128 RS-422A Machine Control Data Routing Switch Screen NV3128 RS-422A Machine Control Data Routing Switch Theoryofoperation NV3128 RS-422A Machine-Control Data Routing Switch Control Structure SystemNV3128 RS-422A Machine-Control Data Routing Switch Assy EM0038-XX 1 I/O Connector InterfaceSignal Backplane Circuit OperationOutput Data Crosspoint Module Assy EM0041-XXInput Data Crosspoints4 I/O Assembly EM0040-XX Mapping Partitioning Parallel Interface Command Interpreter onlyPower Regulation Asynchronous TimingPower Supply Assy PS2001-XX NV3128 RS-422A Machine-Control Data Routing Switch NV3128 RS-422A Machine-Control Data Routing Switch Maintenanceand Troubleshooting NV3128 RS-422A Machine Control Data Routing Switch Customer Support Scheduled MaintenanceReliability Isolating Faults TroubleshootingPower Mapping and Command Problems Signal PathNV3128 RS-422A Machine Control Data Routing Switch Glossary NV3128 RS-422A Machine-Control Data Routing Switch AES/EBU MOV Vcxo NV3128 RS-422A Machine-Control Data Routing Switch Index NV3128 RS-422A Machine-Control Data Switch Index-2 Index NV3128 RS-422A Machine-Control Data Switch Index-4 NV3128 RS-422A Machine-Control Data Switch Index-5 NV3128 RS-422A Machine-Control Data Switch Index-6