3.2 COMPUTER UTILITIES (OBSOLETE)

The following information applies only to older systems with the

Command Interpreter module. Newer systems with the Universal

Control module use UniDiag instead of the NVUtils described below.

See the UniDiag manual for details.

NVUtils is a collection of PC compatible computer programs that provide diagnostics and control of the NVision family of digital routing switches. The utilities currently consist of two programs, NVTake and NVMap. Both programs communicate with the router Control Interface Module using RS- 232 data-exchange protocol, requiring either the configuration of the module for that protocol or the intervention of an RS232/RS-422Aconverter.

Software installation and hardware configuration are detailed in Chapter 2 of thismanual.

NVTAKE

NVtake is a simple, minimally featured router control system. The program sends takes and take salvos to the routing switch Control Interface Module using controller commands from a long and growing list of protocols. Take salvos can be saved to disk and reloaded. For some protocols, the program enables crosspoint address queries and listings.

NVMAP

NVMap is a multi-purpose configuration and diagnostic tool. It allows the user to:

1.Query the router’s crosspoints connections

2.Query the router’s output monitor connections (for routing switches that support output monitors).

3.Query and edit the configuration of the router/control interface.

4.Remap the correlation between received controller addresses and the physical switch addresses (the “scramble map”). This ability greatly enhances the NV3128's ability to mesh with existing router control systems.

NVMap also provides diagnostic messages showing the results of controller commands sent to the router.

NV3128 RS-422A Machine Control Data Routing Switch

3-5

Image 53
Contents Nvision PrintingHistory WarrantyStatement TechnicalSupport ImportantSafeguardsandNotices Page Page NorthAmericanPowerSupplyCords Tableofcontents Page Generalinformation NV3128 RS-422A Machine-Control Data Switch General GeneralinformationArchitecture Background NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch Solution Dynamic Ports Crosspointarchitecture NV3128 RS-422A Machine-Control Data Switch Physical Multidrop Command ChainsAncillary Equipment System Specifications1NV3128SPECIFICATIONS Installation NV3128 RS-422A Machine-Control Routing Switch Chapter TWO Installation NV3128 RS-422A Machine-Control Routing Switch Frame Installation Partitioning Obsolete Universal Control or Command InterpreterPartition DIP Switches Obsolete RE-INITIALIZE BIT/MULTIDROP Enable s7 SettingsInput Length s8-s5 Matrix Control II Jumpers ObsoleteRS-422A RS-232 Parallel Interface Obsolete Configuring the Diagnostic Interface ObsoleteJumper Enabled Disabled Reference Input Ground Obsolete Configuring the Reference InputCabling the NV3128 Cabling the Serial Command InterfacePIN RS-232 DCE VS. DTE Decision Obsolete RS232 ObsoletePIN Connector Implementing HOT Changeover Obsolete Adding a Redundant ControllerCabling Complete PC Diagnostic Interface UNIDIAG/NVUTILSRear Connections NEW Frame Rear Ections OLD Frame Rearconnections OLD Frame Installation PC-BASED Software Installation ObsoleteGeneral NvtakeSample Install Session Software Installation Fixed DiskOperation from a Floppy Disk Hardware ConfigurationOperation NV3128 RS-422A Machine Control Data Routing Switch Connection Notes OperationsMultidrop Connection Rules POINT-TO-POINT Connection RulesComputer Utilities Obsolete Invocation Operating Instructions Nvtake ObsoleteOperations F3 Change Router LevelF1 Sending a Single Take F9 Build a Salvo Table F2 Send a Salvo F10 Load a Salvo from DiskF6 List Destinations Connected to a Source F5 Query Multiple ConnectionsOperation Operating Instructions Nvmap ObsoleteNV3128 RS-422A Machine Control Data Routing Switch Screen NV3128 RS-422A Machine Control Data Routing Switch Theoryofoperation NV3128 RS-422A Machine-Control Data Routing Switch Control Structure SystemNV3128 RS-422A Machine-Control Data Routing Switch Signal Backplane 1 I/O Connector InterfaceCircuit Operation Assy EM0038-XXInput Data Crosspoint Module Assy EM0041-XXCrosspoints Output Data4 I/O Assembly EM0040-XX Mapping Power Regulation Parallel Interface Command Interpreter onlyAsynchronous Timing PartitioningPower Supply Assy PS2001-XX NV3128 RS-422A Machine-Control Data Routing Switch NV3128 RS-422A Machine-Control Data Routing Switch Maintenanceand Troubleshooting NV3128 RS-422A Machine Control Data Routing Switch Reliability Scheduled MaintenanceCustomer Support Power TroubleshootingIsolating Faults Mapping and Command Problems Signal PathNV3128 RS-422A Machine Control Data Routing Switch Glossary NV3128 RS-422A Machine-Control Data Routing Switch AES/EBU MOV Vcxo NV3128 RS-422A Machine-Control Data Routing Switch Index NV3128 RS-422A Machine-Control Data Switch Index-2 Index NV3128 RS-422A Machine-Control Data Switch Index-4 NV3128 RS-422A Machine-Control Data Switch Index-5 NV3128 RS-422A Machine-Control Data Switch Index-6