Metal oxide varistors DV1 and DV2 clamp voltage spikes on the AC input lines to safe levels.

Further, the PS2001 automatically bleeds all input capacitors when the unit is removed from the frame. Normally, a diode is connected to ground through the backplane, biasing FET Q4 off. Upon removal of the module from the frame, the FET conducts, quickly discharging the capacitors, thus minimizing the chance of electrical shock.

Switching FETs Q1 and Q2 chop the high voltage DC at 40 kHz into a square wave. The resulting square wave is subsequently fed into a step-downtransformer. The secondary side of the transformer has two identical sets of windings which feed full-wave rectifiers. The use of Schottky diodes for the rectifiers minimizes voltage losses in the outputs.

Inductors and capacitors form two-stage filters for the secondary rectifiers. They produce low voltage DC outputs at approximately +/-16 to +/-18 Volts and +/- 6 to +/-8 Volts. Schottky diodes assure proper load sharing among redundant supplies.

A pulse width modulation submodule tightly regulates the secondary outputs. A primary-side auxiliary winding on transformer T1 monitors the flux and feeds back a relative voltage to U1. This feedback governs the pulse width of the submodule's outputs, thereby regulating the drive signal applied to the switching FETs.

Aboot-strap multivibrator circuit on the submodule initializes the power-supply circuitry.

Although each of the NV3128 modules has its own on-board voltage regulators and current limiters, the power supply itself is self limiting. Transformer T2 monitors the primary current and steps it down to a level where it can safely drive the PWM submodule, shutting it down completely in case of excessive load. Operation resumes immediately when the overload is corrected.

NV3128 RS-422A Machine-Control Data Routing Switch

4-11

Image 73
Contents Nvision PrintingHistory WarrantyStatement TechnicalSupport ImportantSafeguardsandNotices Page Page NorthAmericanPowerSupplyCords Tableofcontents Page Generalinformation NV3128 RS-422A Machine-Control Data Switch General GeneralinformationArchitecture Background NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch NV3128 RS-422A Machine-Control Data Switch Solution Dynamic Ports Crosspointarchitecture NV3128 RS-422A Machine-Control Data Switch Physical Multidrop Command ChainsAncillary Equipment System Specifications1NV3128SPECIFICATIONS Installation NV3128 RS-422A Machine-Control Routing Switch Chapter TWO Installation NV3128 RS-422A Machine-Control Routing Switch Frame Installation Partitioning Obsolete Universal Control or Command InterpreterPartition DIP Switches Obsolete RE-INITIALIZE BIT/MULTIDROP Enable s7 SettingsInput Length s8-s5 Matrix Control II Jumpers ObsoleteRS-422A RS-232 Parallel Interface Obsolete Configuring the Diagnostic Interface ObsoleteJumper Enabled Disabled Reference Input Ground Obsolete Configuring the Reference InputCabling the NV3128 Cabling the Serial Command InterfacePIN RS-232 DCE VS. DTE Decision Obsolete RS232 ObsoletePIN Connector Implementing HOT Changeover Obsolete Adding a Redundant ControllerCabling Complete PC Diagnostic Interface UNIDIAG/NVUTILSRear Connections NEW Frame Rear Ections OLD Frame Rearconnections OLD Frame Installation PC-BASED Software Installation ObsoleteGeneral NvtakeSample Install Session Software Installation Fixed DiskOperation from a Floppy Disk Hardware ConfigurationOperation NV3128 RS-422A Machine Control Data Routing Switch Connection Notes OperationsMultidrop Connection Rules POINT-TO-POINT Connection RulesComputer Utilities Obsolete Invocation Operating Instructions Nvtake ObsoleteOperations F3 Change Router LevelF1 Sending a Single Take F9 Build a Salvo Table F2 Send a Salvo F10 Load a Salvo from DiskF6 List Destinations Connected to a Source F5 Query Multiple ConnectionsOperation Operating Instructions Nvmap ObsoleteNV3128 RS-422A Machine Control Data Routing Switch Screen NV3128 RS-422A Machine Control Data Routing Switch Theoryofoperation NV3128 RS-422A Machine-Control Data Routing Switch Control Structure SystemNV3128 RS-422A Machine-Control Data Routing Switch Signal Backplane 1 I/O Connector InterfaceCircuit Operation Assy EM0038-XXInput Data Crosspoint Module Assy EM0041-XXCrosspoints Output Data4 I/O Assembly EM0040-XX Mapping Power Regulation Parallel Interface Command Interpreter onlyAsynchronous Timing PartitioningPower Supply Assy PS2001-XX NV3128 RS-422A Machine-Control Data Routing Switch NV3128 RS-422A Machine-Control Data Routing Switch Maintenanceand Troubleshooting NV3128 RS-422A Machine Control Data Routing Switch Customer Support Scheduled MaintenanceReliability Isolating Faults TroubleshootingPower Mapping and Command Problems Signal PathNV3128 RS-422A Machine Control Data Routing Switch Glossary NV3128 RS-422A Machine-Control Data Routing Switch AES/EBU MOV Vcxo NV3128 RS-422A Machine-Control Data Routing Switch Index NV3128 RS-422A Machine-Control Data Switch Index-2 Index NV3128 RS-422A Machine-Control Data Switch Index-4 NV3128 RS-422A Machine-Control Data Switch Index-5 NV3128 RS-422A Machine-Control Data Switch Index-6