E201E

POST memory

BIOS POST memory test

See "Troubleshooting

 

test failure.

failure.

System Memory" on

 

Check DIMMs.

 

page 165.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E2020

CPU

Processor configuration

Check screen for specific

 

configuration

failure.

error messages.

 

failure. Check

 

See "Troubleshooting

 

screen

 

Processors" on page 174.

 

message.

 

 

E2021

Incorrect

Incorrect memory

Check screen for specific

 

memory

configuration.

error messages. See

 

configuration.

 

"Troubleshooting System

 

Review User

 

Memory" on page 165.

 

Guide.

 

 

E2022

General

General failure after video. Check screen for specific

 

failure

 

error messages.

 

during POST.

 

 

 

Check screen

 

 

 

message.

 

 

E2110

Multibit Error

The memory module in

See "Troubleshooting

 

on DIMM ##.

slot “##” has had a

System Memory" on

 

Reseat DIMM.

multi-bit error (MBE).

page 165.

E2111

SBE log

The system BIOS has

Remove AC power to the

 

disabled on

disabled memory

system for 10 seconds and

 

DIMM ##.

single-bit error (SBE)

restart the system.

 

Reseat DIMM.

logging and does not log

If the problem persists,

 

 

anymore SBEs until the

see "Troubleshooting

system is rebooted. "##"

System Memory" on

represents the memory

page 165.

module implicated by

 

the BIOS.

 

About Your System

37

Image 37
Contents Dell PowerEdge R515 Systems August Contents Entering the Uefi Boot Manager Choosing the System Boot ModeOther Information You May Need Embedded System Management IDRAC6 Configuration UtilityOpening and Closing the System Removing a Hard Drive From a Integrated Storage Controller Card Control Panel Assembly-LEDIDRAC6 Express Card Optional IDRAC6 Enterprise Card Optional143 140148 152Embedded System Diagnostics Features Troubleshooting Expansion Cards 172When to Use the Embedded System Diagnostics Running the Embedded System Diagnostics181 Disabling a Forgotten Password 184182 187Keystroke Description Accessing System Features During StartupFront-Panel Features and Indicators AC power and an error has been Indicator, Button Icon Description Or Connector Image, depending on the amount LCD Panel Features Buttons Description LCD Panel Features OptionalButtons Description Home ScreenView Menu Setup MenuOption Description OptionDescriptionHard-Drive Indicators Hard-Drive Indicator PatternsDrive-Status Indicator Pattern Condition Back-Panel Features and IndicatorsIndicator, Button, or Icon Description Connector Indicator, Button, or Icon Description Connector NIC Indicator Codes Guidelines for Connecting Optional External DevicesIndicator Indicator Code Power Supply Status Indicator Power Indicator CodesDiagnostic Indicator Codes Causes Corrective Action Diagnostic Lights OptionalDiagnostic Indicator Codes Causes Corrective Action Code Text Causes Corrective Actions LCD Status Messages OptionalAmbient temperature has See Troubleshooting VTT voltage regulator See Troubleshooting Getting Started Guide System Bios has Specified power supplys Check the AC power Reported a PCI parity IDRAC6 Express Memory configured See Troubleshooting Programmable interval Remove AC power to Bios Post memory test See Troubleshooting Spared the memory Removing LCD Status Messages Solving Problems Described by LCD Status MessagesMessage Causes Corrective Actions System MessagesMemory configuration Ensure that the memory System is in manufacturing Reboot to take the system Mismatched processors have Ensure that all processors Invalid memory Ensure that the memory Overcurrent detected at See Getting Help on Memtest lane Incorrect configuration Check the hard drive There is no device connected Information only Match in rank Count x,x Following DIMMs should Match in size Memory module without a Replace the memory Integrated Dell Remote Unsupported Processors, memory Were just upgraded Write fault Write fault on selected drive Alert Messages Diagnostics MessagesOther Information You May Need Choosing the System Boot Mode Using the System Setup Program and Uefi Boot ManagerResponding to Error Messages Entering the System Setup ProgramUsing the System Setup Program Navigation Keys Keys ActionMain Screen System Setup OptionsPCI IRQ Processor Settings Screen Memory Settings ScreenC1E Sata Settings Screen OptionalNot installed in the same boot mode Boot Settings ScreenEmulation Type fields Integrated Devices Screen All Ports On defaultSerial Communication Screen PCI IRQ Assignments ScreenEmbedded Server Management Screen VT100/VT220 default VT100/VT220 or AnsiSystem Security Screen Power Management ScreenTPM keys prior to enabling this option More informationExit Screen Diagnostic screenDo so by qualified support personnel or by Using the Uefi Boot Manager Navigation Keys Entering the Uefi Boot ManagerUefi Boot Settings Screen Uefi Boot Manager ScreenUsing the System Password System and Setup Password FeaturesAssigning a System Password System Utilities ScreenUsing Your System Password to Secure Your System Verify that Password Status is UnlockedChanging an Existing System Password Disabling the System PasswordAssigning a Setup Password Using the Setup PasswordOperating With a Setup Password Enabled Embedded System Management Deleting or Changing an Existing Setup PasswordEntering the BMC Setup Module Baseboard Management Controller ConfigurationEntering the iDRAC6 Configuration Utility IDRAC6 Configuration UtilityInside the System Recommended ToolsInside the System Eight-Hard-Drive System Inside the System Twelve-Hard-Drive System Removing the Front Bezel Front Bezel OptionalOpening and Closing the System Installing the Front BezelOpening the System System cover latch Closing the System Removing the Cooling Shroud Cooling ShroudHard Drives Installing the Cooling ShroudRemoving a Hard-Drive Blank Removing a Hard Drive Installing a Hard-Drive BlankRemoving and Installing a Hard Drive Installing a Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Drive CarrierInternal Hard Drives Installing a Hard Drive Into a Hard-Drive CarrierRemoving an Internal Hard-Drive Bay Came with the product10. Removing and Installing an Internal Hard-Drive Bay Installing an Internal Hard-Drive Bay Installing a Hard Drive Into a Hard-Drive Bay Removing an Optical Drive Optical Drive Optional12. Removing and Installing the Optical Drive Installing an Optical DriveCooling Fans Removing a Cooling Fan 13. Removing and Installing a Fan Eight-Hard-Drive System 100 14. Removing and Installing a Fan Twelve-Hard-Drive System101 Installing a Cooling FanRemoving a Power Supply Power Supplies102 103 Installing a Power SupplyInstalling the Power Supply Blank Removing the Power Supply BlankSystem Memory 104105 General Memory Module Installation GuidelinesMode-Specific Guidelines Optimizer Independent Channel Mode106 Single Processor Dual Processor Module 107Size Physical Available Memory Single Processor Dual Processor Memory108 Installing Memory Modules109 16. Removing and Installing a Memory Module110 Removing Memory ModulesExpansion Cards and Expansion-Card Risers Expansion Card Installation Guidelines111 Perc H800 Hpcc 112113 Installing an Expansion Card114 17. Removing and Installing an Expansion Card115 Removing an Expansion Card116 Removing an Expansion-Card Riser117 18. Removing and Installing an Expansion-Card Riser118 Installing an Expansion-Card RiserRemoving the Storage Controller Card Integrated Storage Controller Card119 120 19. Removing and Installing the Storage Controller Card121 Installing the Storage Controller CardIDRAC6 Express Card Optional Installing an iDRAC6 Express Card122 123 Removing an iDRAC6 Express CardIDRAC6 Enterprise Card Optional Installing an iDRAC6 Enterprise Card124 125 21. Removing and Installing an iDRAC6 Enterprise Card126 Removing an iDRAC6 Enterprise CardVFlash Media Optional Installing a VFlash Media CardInternal USB Memory Key Removing a VFlash Media CardRemoving a Processor Processors128 129 130 23. Removing and Installing the Heat Sink131 24. Removing and Installing a Processor132 Installing a ProcessorReplacing the System Battery System Battery133 134 25. Replacing the System Battery135 Removing the RAID Battery RAID Battery Optional136 Installing the RAID Battery Control Panel Assembly-LEDRemoving the Control-PanelModule-LED 137138 27. Removing and Installing the Control Panel-LED139 Installing the Control-Panel Module-LEDRemoving the Control Panel Display Module Control Panel Assembly-LCD Optional140 Removing the Control Panel Assembly Installing the Control Panel Display Module141 142 28. Removing and Installing the Control Panel-LCDSAS Backplane Installing the Control Panel AssemblyRemoving the SAS Backplane 143144 145 146 147 Installing the SAS BackplaneRemoving the Power Distribution Board Power Distribution Board148 149 150 151 Replacing the Power Distribution BoardRemoving the System Board System Board152 153 33. Removing and Installing the System Board154 Installing the System Board155 156 157 Troubleshooting External ConnectionsTroubleshooting a USB Device Troubleshooting the Video Subsystem158 Troubleshooting a NIC Troubleshooting a Serial I/O Device159 160 Troubleshooting a Wet System161 Troubleshooting the System Battery Troubleshooting a Damaged System162 Troubleshooting System Cooling Problems Troubleshooting Power Supplies163 164 Troubleshooting a Fan165 Troubleshooting System Memory166 167 Troubleshooting an Internal USB Key168 Troubleshooting an Optical Drive169 Troubleshooting a Hard Drive170 Troubleshooting an Internal Hard Drive171 Troubleshooting a Storage Controller172 Troubleshooting Expansion Cards173 174 Troubleshooting Processors175 176 Embedded System Diagnostics Features Using Online Diagnostics177 Running the Embedded System Diagnostics When to Use the Embedded System Diagnostics178 Using the Custom Test Options Embedded System Diagnostics Testing OptionsSelecting Devices for Testing Selecting Diagnostics Options180 Viewing Information and ResultsSystem Board Jumpers System Board Jumper Settings Description181 182 System Board Connectors183 System Board Connectors Description184 Disabling a Forgotten Password185 186 187 Contacting Dell188 189 Index190 191 Post192 193 USB194