Code | Text | Causes | Corrective Actions |
E2112 Memory spared | The system BIOS has |
on DIMM ##. | spared the memory |
Power cycle | because it has determined |
AC. | the memory had too many |
| errors. "##" represents the |
| memory module |
| implicated by the BIOS. |
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists, see "Troubleshooting System Memory" on page 165.
I1910 Intrusion | System cover has been | Information only. |
detected. | removed. |
|
Check chassis |
|
|
cover. |
|
|
I1912 System Event | The SEL is full of events |
Log full. | and is unable to log any |
Review & | more. |
clear log. |
|
Check the SEL for details on the events, then clear the SEL.
I1920 iDRAC6 Upgrade | Optional iDRAC6 has | Information only. |
Successful | been upgraded |
|
| successfully. |
|
W1228 RAID | Warns predictively that |
Controller | the RAID battery has |
battery | less than 24 hours of |
capacity < | charge left. |
24hr. |
|
Allow RAID battery to charge to greater than 24 hours of sustained charge.
If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 137.
W1627 Power required The system configuration
>PSU wattage. requires more power
Check PSU and | than what the power |
config. | supply can provide. |
Turn off power to the system, reduce the hardware configuration or install
38
About Your System