Message | Causes | Corrective Actions |
|
|
|
Alert! Node | The memory configuration | Ensure that the memory |
Interleaving | does not support node | modules are installed in a |
disabled! Memory | interleaving, or the | configuration that supports |
configuration | configuration has changed | node interleaving. |
does not support | (for example, a memory | Check other system |
Node | module has failed) so that | messages for additional |
Interleaving. | node interleaving cannot be | information for possible |
| supported. The system still | causes. For memory |
| runs, but without node | configuration information, |
| interleaving. | see "General Memory |
|
| Module |
|
| Installation Guidelines" on |
|
| page 105. If the problem |
|
| persists, |
|
| see "Troubleshooting System |
|
| Memory" on page 165. |
|
|
|
Alert! Power | The system configuration | If any system components |
required exceeds | of processor(s), | were just upgraded, |
PSU wattage. | memory modules, | return the system to the |
Check PSU and | and expansion cards may | previous configuration. |
system | not be supported by the | If the system boots without |
configuration. | power supplies. | this warning, then the |
Alert! |
| replaced component(s) are |
| not supported with this | |
Continuing |
| |
| power supply. If Energy | |
system boot |
| |
| Smart power supplies are | |
accepts the risk |
| |
| installed, replace them with | |
that system may |
| |
| High Output power supplies | |
power down |
| |
| to use the components. | |
without warning. |
| |
| See "Power Supplies" on | |
|
| |
|
| page 102. |
|
|
|
Alert! System | An error caused the | Check other system |
fatal error | system to reboot. | messages for additional |
during previous |
| information for possible |
boot. |
| causes. |