Dell 610 ICU Error Messages, Table C-1. Configuration Utility Messages Probable Cause

Page 101

ISA Configuration Utility Messages: Dell™ Precision™ WorkStation 610 Mini Tower Systems

Overview ICU Error Messages Configuration Manager Messages

Overview

The ISA Configuration Utility (ICU) and its Configuration Manager are capable of identifying problems and alerting you to them. Both utilities can alert you to problems with card configuration as well as problems that prevent proper operation of the utility. This appendix describes each type of message and lists the possible causes and actions you can take to resolve any problems indicated by a message. See the following tables to locate your message and identify any possible corrective actions.

ICU Error Messages

The ICU can display a variety of error messages while in operation. These messages alert you to problems that prevent the ICU from running correctly, as well as informing you of resource conflicts that prevent the configuration of various cards in your computer. If you receive a message from the ICU, see Table C-1 for suggestions on resolving any problems indicated by the message.

Table C-1. Configuration Utility Messages

Message

Probable Cause

Out of memory

Either of these messages can

Memory allocation failed

appear if the system runs out of

 

memory during your operation.

Corrective Action

Disable any terminate-and-stay-resident (TSR) programs or any unneeded device drivers.

Not enough memory to run the

This message appears when

ICU

you start the ICU if the system

 

does not have enough memory

 

to run the utility.

Can't open index file.

This file is required for ICU to run.

No Configuration Manager.

At least one Plug and Play card in your system is not configured due to conflicts. These are marked "config err" in the list of configured cards.

Due to conflicts, the ICU could only configure some Plug and Play cards in your system. Unconfigured cards are marked "config err" in the list of configured

The ICU cannot find the index file for its database.

The device driver needed by the ICU is corrupted or is not correctly configured.

The Configuration Manager or the ICU cannot configure at least one Plug and Play expansion card because of resource conflicts with one or more cards.

Make sure to switch to drive A before attempting to start the utility.

Verify that the following device statement appears in your config.sys file: device= drive:\ directory\ drivers\dos\dwcfgmg.sys

In this statement, drive and directory represent the drive and directory where the driver resides. The default is c:\plugplay.

You must reconfigure the conflicting card(s). To find the conflicting card, perform the following steps:

1.Select the Plug and Play expansion card marked with config err, and then click Modify.

The Card Configuration dialog box displays the functions assigned to the Plug and Play expansion card.

2.Select a function and then click Settings. Click

Image 101
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge Overview System FeaturesPage Page Important Note to Windows NT 4.0 Users Reinstalling Windows NTCreating Disk Partitions for Windows NT Front PanelBack Panel Security Cable Slot and Padlock Ring Connecting External DevicesGetting Help Software Support Utilities on Diskette Dell-Installed Software Support UtilitiesBacking Up the Software Support Utilities Asset Tag Utility System Utilities and ServicesRemoving a Service Assigning and Deleting an Asset Tag Number Dell AutoShutdown ServiceAsset 1234$ABCD Assigning and Deleting an Owner TagInstalling the Auto Power On Utility Dell ThermalShutdown ServiceAuto Power On Utility Removing the Windows NT 4.0 Microsoft Updated Atapi Driver Microsoft Updated Atapi DriversSystem Setup Screen Entering the System Setup ProgramSystem-Setup Navigation Keys Keys Action Using the System Setup ProgramSystem Time System Setup OptionsDiskette Drive a and Diskette Drive B System DatePrimary Drive and Secondary Drive Eide DevicesIf You Have a Problem Boot SequenceHard-Disk Drive Sequence If You Know the Drive-Type NumberReserved Memory System MemoryCPU Speed PXENIC CPU IDsIntegrated Devices IDE Drive Interface Parallel Port ModeDiskette Interface PC SpeakerPassword Status System PasswordSetup Password System SecurityAuto Power On Report Keyboard ErrorsKeyboard NumLock Wakeup On LANSaving Eide Hard-Disk Drive Power Power ManagementSaving Monitor Power System Data Options Thermal Power-OffAsset Tag Assigning a System Password Using the System Password FeatureDeleting or Changing an Existing System Password Type the password and press EnterOperating With a Setup Password Enabled Using the Setup Password FeatureAssigning a Setup Password Deleting or Changing an Existing Setup Password Disabling a Forgotten PasswordInformation on resetting the chassis intrusion detector Responding to Error MessagesQuick Start ICU Database When to Run the ICUAbout the ICU Preparing to Use the ICU Accessing HelpStarting the ICU Backing Up the ICU DisketteKeyss Action Adding a Listed CardCard Configuration Dialog Box Adding an Unlisted Card Available Settings List BoxSpecify Interrupt Dialog Box Specify I/O Port Dialog Box Modifying a CardRemoving a Card Viewing Resources Saving the System ConfigurationExiting the ICU Locking and Unlocking CardsLocking and Unlocking All Resources Locking and Unlocking Configuration ResourcesPage NIC Connector and Indicators Connecting to a NetworkWindows NT 4.0 NIC Driver Configuring the NICNetwork Cable Requirements Setting the Network Frame Type Manually Configuring a 3Com PCI 3C905b NICReinstallation Speakers Connecting Audio DevicesAdjusting Volume in Windows NT Adjusting VolumeMicrophones Record/Playback DevicesUsing Audio Utilities Adjusting 3D SoundInstalling Audio Drivers Muting the Internal SpeakerScsi Device Considerations Scsi Drivers for Windows NT Installing Scsi DriversPage Unpacking Your Hardware Option Safety First-For You and Your ComputerBefore You Begin Replacing the Computer Cover Removing the Computer CoverReplacing the Computer Cover Inside Your ComputerRotating the Power Supply Rotating the Power Supply Away From the System BoardExpansion Cards System Board FeaturesExpansion Slots Installing an Expansion CardRemoving the Filler Bracket Removing an Expansion CardAdding Memory Dimm Installation GuidelinesTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal See Using the System Setup Program Replacing the System BatterySystem Battery and Battery Socket Obtaining technical assistance Drive Locations Removing and Replacing the Front BezelRemoving and Replacing Front-Panel Inserts Connecting DrivesDC Power Cable Connector Installing a Drive in a 5.25-Inch Drive BayRemoving a Drive Inserting the New Drive Into the Drive Bay Eide Drive Addressing Installing an Eide Hard-Disk Drive10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Scsi ID Numbers Installing Scsi DevicesScsi Configuration Guidelines Scsi Cables General Procedure for Installing Scsi DevicesDevice Termination ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives Expansion Bus Table A-1. Technical Specifications ProcessorSystem Information Drives Ports and ConnectorsSystem Clocks Key Combinations Controls and IndicatorsPhysical Page Jumpers Jumpers and Switches-A General ExplanationSwitches Reserved do not remove jumper PARALLEL/SCSI System Board LabelsSerial and Parallel Ports Ports and ConnectorsSerial Port Connectors Parallel Port Connector Dparh External Scsi ConnectorKeyboard Connector Keyboard and Mouse ConnectorsMouse Connector Video ConnectorNIC Connector Microphone Jack USB ConnectorsLine-Out Jack Interrupt AssignmentsLine-In Jack Table B-9. Interrupt Assignments IRQ Line Used By/AvailableTable B-10. Conventional Memory Map Address Range Use Memory AllocationsTable B-11. Upper Memory Map Address Range Use Corrective Action ICU Error MessagesTable C-1. Configuration Utility Messages Probable Cause Listed Card or Adding an Unlisted Card for instructions Change to the db subdirectory on the diskette drive Configuration Manager MessagesTable C-2. Configuration Manager Messages Page Cards mentioned Page Backup Devices Scheduling BackupsRecovering Data Data PreservationCleaning the Computer, Monitor, and Keyboard Exteriors Cleaning System ComponentsRecommended Tools and Accessories Temperature Cleaning DrivesEnvironmental Factors HumidityDust and Particles AltitudeCorrosion ESDShock and Vibration Power Source InterruptionsMagnetism Power Protection Devices Overview Class a Class B FCC Notices U.S. OnlyIC Notice Canada Only EN 55022 Compliance Czech Republic Only CE Notice European UnionVcci Notice Japan Only Class a ITEClass a Device MOC Notice South Korea OnlyClass B ITE Class B Device Polish Center for Testing and Certification NoticeExporter NOM Information Mexico OnlyOne Dell Way Round Rock, TXInformación para NOM únicamente para México Coverage During Years Two and Three Overview Limited Three-Year Warranty U.S. and Canada OnlyCoverage During Year One General Total Satisfaction Return Policy U.S. and Canada OnlyADI AcpiAGP AsciiAspi AsicBBS BiosBTU Cmos CD-ROMDAT CPUDIN DimmDIP DMADpms DmtfDram DTEECP ECCEeprom EideFAT EMSEprom FTP FCCHMA GUIHpfs IcesIRQ IPXISA ITEXMM LANLVD LED