Dell 610 technical specifications Removing a Card

Page 41

You have completed this procedure; do not proceed to step 5.

5.To add, modify, or remove a resource value, select the box beneath the resource to be assigned, and then click Add, Modify, or Remove, respectively.

For example, if you click the box beneath IRQ, the Add, Modify, and Remove buttons change to Add Interrupt, Modify Interrupt, and Remove Interrupt. When you click one of these buttons, a smaller Specify list box (in this case, Specify Interrupt) appears.

If you are providing a value for the IRQ or DMA resource, click the down arrow beneath Available Resources. Click the value you want to assign to the resource. If the resource can be shared with another card or device, click Sharable. Then click OK.

If none of the values for the DMA or IRQ resource match the allowable values for your unlisted card (as indicated in the card's documentation), select one of the available values offered by the utility and click OK.

If you are providing values for the I/O port or memory resource, you must enter the starting and ending addresses in hexadecimal format using the two fields provided by the Specify Memory or Specify I/O Port dialog box.

6.When you have finished selecting resources for the unlisted card, click OK in the Configure Unlisted Card dialog box.

A message box appears, notifying you either that the card is using its default settings or that it cannot use its default settings and must be reconfigured.

7.Click OK. If the card must be reconfigured, record the resource settings recommended by the ICU. Click Close to accept the resource settings currently displayed.

8.If you had to assign a disallowed resource value to the card in steps 5, 6, and 7, click each of the other cards, and then click View until you find another card using a resource value that is allowed for the unlisted card. Reassign the resource setting for this other card. Then modify the resource settings for the unlisted card so that it uses an allowable value.

NOTE: After modifying the system configuration, you must turn off the system to install, remove, or change jumper settings on the non-Plug and Play ISA expansion cards to match the settings you selected in the ICU.

Removing a Card

Before you remove a non-Plug and Play ISA expansion card from your computer, you must use the ICU to remove the card from the system configuration.

NOTE: When you remove a Plug and Play or PCI expansion card from your computer, you do not need to run the ICU. To remove a Plug and Play or PCI expansion card, complete steps 2 through 8 in "Removing an Expansion Card".

Use the following procedure to remove a non-Plug and Play ISA expansion card from your computer:

1.Start the ICU as described in "Starting the ICU".

2.Select the card from the current system configuration list in the ICU window.

3.Select Remove Card from the Configuration menu, or click Remove. The ICU requests verification that you want to remove the card.

4.Click Yes to free the resources allocated to the card and remove the card's name from the list of active cards, or click No to cancel the operation.

The ICU returns to the ICU window.

CAUTION: After removing a card from the system configuration using the ICU, you must turn off the system and physically remove the card. Failure to do so can damage your system.

5.Remove the non-Plug and Play ISA expansion card from the computer. See "Removing an Expansion Card" for instructions.

Image 41
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge Overview System FeaturesPage Page Important Note to Windows NT 4.0 Users Reinstalling Windows NTCreating Disk Partitions for Windows NT Front PanelBack Panel Security Cable Slot and Padlock Ring Connecting External DevicesGetting Help Software Support Utilities on Diskette Dell-Installed Software Support UtilitiesBacking Up the Software Support Utilities Asset Tag Utility System Utilities and ServicesRemoving a Service Assigning and Deleting an Asset Tag Number Dell AutoShutdown ServiceAsset 1234$ABCD Assigning and Deleting an Owner TagInstalling the Auto Power On Utility Dell ThermalShutdown ServiceAuto Power On Utility Removing the Windows NT 4.0 Microsoft Updated Atapi Driver Microsoft Updated Atapi DriversSystem Setup Screen Entering the System Setup ProgramSystem-Setup Navigation Keys Keys Action Using the System Setup ProgramSystem Time System Setup OptionsDiskette Drive a and Diskette Drive B System DatePrimary Drive and Secondary Drive Eide DevicesIf You Have a Problem Boot SequenceHard-Disk Drive Sequence If You Know the Drive-Type NumberReserved Memory System MemoryCPU Speed PXENIC CPU IDsIntegrated Devices IDE Drive Interface Parallel Port ModeDiskette Interface PC SpeakerPassword Status System PasswordSetup Password System SecurityAuto Power On Report Keyboard ErrorsKeyboard NumLock Wakeup On LANSaving Eide Hard-Disk Drive Power Power ManagementSaving Monitor Power System Data Options Thermal Power-OffAsset Tag Assigning a System Password Using the System Password FeatureDeleting or Changing an Existing System Password Type the password and press EnterOperating With a Setup Password Enabled Using the Setup Password FeatureAssigning a Setup Password Deleting or Changing an Existing Setup Password Disabling a Forgotten PasswordInformation on resetting the chassis intrusion detector Responding to Error MessagesQuick Start ICU Database When to Run the ICUAbout the ICU Preparing to Use the ICU Accessing HelpStarting the ICU Backing Up the ICU DisketteKeyss Action Adding a Listed CardCard Configuration Dialog Box Adding an Unlisted Card Available Settings List BoxSpecify Interrupt Dialog Box Specify I/O Port Dialog Box Modifying a CardRemoving a Card Viewing Resources Saving the System ConfigurationExiting the ICU Locking and Unlocking CardsLocking and Unlocking All Resources Locking and Unlocking Configuration ResourcesPage NIC Connector and Indicators Connecting to a NetworkWindows NT 4.0 NIC Driver Configuring the NICNetwork Cable Requirements Setting the Network Frame Type Manually Configuring a 3Com PCI 3C905b NICReinstallation Speakers Connecting Audio DevicesAdjusting Volume in Windows NT Adjusting VolumeMicrophones Record/Playback DevicesUsing Audio Utilities Adjusting 3D SoundInstalling Audio Drivers Muting the Internal SpeakerScsi Device Considerations Scsi Drivers for Windows NT Installing Scsi DriversPage Unpacking Your Hardware Option Safety First-For You and Your ComputerBefore You Begin Replacing the Computer Cover Removing the Computer CoverReplacing the Computer Cover Inside Your ComputerRotating the Power Supply Rotating the Power Supply Away From the System BoardExpansion Cards System Board FeaturesExpansion Slots Installing an Expansion CardRemoving the Filler Bracket Removing an Expansion CardAdding Memory Dimm Installation GuidelinesTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal See Using the System Setup Program Replacing the System BatterySystem Battery and Battery Socket Obtaining technical assistance Drive Locations Removing and Replacing the Front BezelRemoving and Replacing Front-Panel Inserts Connecting DrivesDC Power Cable Connector Installing a Drive in a 5.25-Inch Drive BayRemoving a Drive Inserting the New Drive Into the Drive Bay Eide Drive Addressing Installing an Eide Hard-Disk Drive10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Scsi ID Numbers Installing Scsi DevicesScsi Configuration Guidelines Scsi Cables General Procedure for Installing Scsi DevicesDevice Termination ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives Expansion Bus Table A-1. Technical Specifications ProcessorSystem Information Drives Ports and ConnectorsSystem Clocks Key Combinations Controls and IndicatorsPhysical Page Jumpers Jumpers and Switches-A General ExplanationSwitches Reserved do not remove jumper PARALLEL/SCSI System Board LabelsSerial and Parallel Ports Ports and ConnectorsSerial Port Connectors Parallel Port Connector Dparh External Scsi ConnectorKeyboard Connector Keyboard and Mouse ConnectorsMouse Connector Video ConnectorNIC Connector Microphone Jack USB ConnectorsLine-Out Jack Interrupt AssignmentsLine-In Jack Table B-9. Interrupt Assignments IRQ Line Used By/AvailableTable B-10. Conventional Memory Map Address Range Use Memory AllocationsTable B-11. Upper Memory Map Address Range Use Corrective Action ICU Error MessagesTable C-1. Configuration Utility Messages Probable Cause Listed Card or Adding an Unlisted Card for instructions Change to the db subdirectory on the diskette drive Configuration Manager MessagesTable C-2. Configuration Manager Messages Page Cards mentioned Page Backup Devices Scheduling BackupsRecovering Data Data PreservationCleaning the Computer, Monitor, and Keyboard Exteriors Cleaning System ComponentsRecommended Tools and Accessories Temperature Cleaning DrivesEnvironmental Factors HumidityDust and Particles AltitudeCorrosion ESDShock and Vibration Power Source InterruptionsMagnetism Power Protection Devices Overview Class a Class B FCC Notices U.S. OnlyIC Notice Canada Only EN 55022 Compliance Czech Republic Only CE Notice European UnionVcci Notice Japan Only Class a ITEClass a Device MOC Notice South Korea OnlyClass B ITE Class B Device Polish Center for Testing and Certification NoticeExporter NOM Information Mexico OnlyOne Dell Way Round Rock, TXInformación para NOM únicamente para México Coverage During Years Two and Three Overview Limited Three-Year Warranty U.S. and Canada OnlyCoverage During Year One General Total Satisfaction Return Policy U.S. and Canada OnlyADI AcpiAGP AsciiAspi AsicBBS BiosBTU Cmos CD-ROMDAT CPUDIN DimmDIP DMADpms DmtfDram DTEECP ECCEeprom EideFAT EMSEprom FTP FCCHMA GUIHpfs IcesIRQ IPXISA ITEXMM LANLVD LED