Dell 610 technical specifications Cards mentioned

Page 105

WARNING: Could not

The card(s) mentioned

configure Plug and Play

are not fully configured

Card Name.

due to resource

WARNING: Could not

conflicts.

 

configure PCI device,

 

ID=DeviceID.

 

Failed to configure Number

 

of Total Count Plug and

 

Play ISA devices. Use your

 

system's configuration

 

utility to resolve conflicts.

 

Press any key to continue.

 

WARNING: Could not

The card(s) mentioned

configure Plug and Play

are not fully configured

Card Name.

due to resource

WARNING: Could not

conflicts.

 

configure PCI device,

 

ID=DeviceID.

 

Failed to configure Number

 

of Total Count Plug and

 

Play ISA devices. Use your

 

system's configuration

 

utility to resolve conflicts.

 

Press any key to continue.

 

WARNING: Boot Device

One of the devices is

conflict detected! CSN=Card

attempting to use one

Select Number Error=Error.

or more resources

If you still receive the error message, contact the manufacturer of the Plug and Play expansion card for assistance.

If you have documentation that lists the allowable resource values for your Plug and Play or PCI expansion card, you can use the following procedure to locate and resolve the resource conflict.

NOTE: If you do not have documentation listing the allowable resource values, see the corrective action for these messages on the following page.

1.Start the ICU.

Any Plug and Play or PCI expansion cards that could not be configured should be marked config err in the list of cards in the ICU window.

2.Select the System Resources option from the View menu.

The System Resource Usage dialog box displays all resources currently used by the system.

3.Select one of the resources used by your Plug and Play or PCI expansion card, and click the Used By Card button.

The Card Resources Usage dialog box identifies which device is using the resource.

4.Repeat step 3 until you have identified all conflicting resources and the cards that use them.

5.Modify the cards as needed to free the resources required by the unconfigured Plug and Play or PCI expansion card.

See "Modifying a Card" for instructions.

If you do not know the allowable resource values for your Plug and Play or PCI expansion card, use the following procedure to locate and resolve the resource conflict:

1.Remove all card configurations from the ICU. See "Removing a Card" for instructions.

2.Reboot your system.

The ICU should automatically configure your Plug and Play or PCI expansion card.

3.Add the ISA expansion cards back into the ICU, resolving any resource conflicts as they arise.

See "Adding a Listed Card" for instructions.

If your Plug and Play or PCI expansion card is not automatically configured when you reboot the system with all other cards removed, you should contact the manufacturer of the card or see the chapter titled "Getting Help" in your Diagnostics and Troubleshooting Guide.

Perform the following procedure:

1. Start the ICU.

Image 105
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge Overview System FeaturesPage Page Important Note to Windows NT 4.0 Users Reinstalling Windows NTFront Panel Back PanelCreating Disk Partitions for Windows NT Connecting External Devices Getting HelpSecurity Cable Slot and Padlock Ring Dell-Installed Software Support Utilities Backing Up the Software Support UtilitiesSoftware Support Utilities on Diskette System Utilities and Services Removing a ServiceAsset Tag Utility Assigning and Deleting an Asset Tag Number Dell AutoShutdown ServiceAsset 1234$ABCD Assigning and Deleting an Owner TagDell ThermalShutdown Service Auto Power On UtilityInstalling the Auto Power On Utility Removing the Windows NT 4.0 Microsoft Updated Atapi Driver Microsoft Updated Atapi DriversSystem Setup Screen Entering the System Setup ProgramSystem-Setup Navigation Keys Keys Action Using the System Setup ProgramSystem Time System Setup OptionsDiskette Drive a and Diskette Drive B System DatePrimary Drive and Secondary Drive Eide DevicesIf You Have a Problem Boot SequenceHard-Disk Drive Sequence If You Know the Drive-Type NumberReserved Memory System MemoryCPU Speed PXECPU IDs Integrated DevicesNIC IDE Drive Interface Parallel Port ModeDiskette Interface PC SpeakerPassword Status System PasswordSetup Password System SecurityAuto Power On Report Keyboard ErrorsKeyboard NumLock Wakeup On LANPower Management Saving Monitor PowerSaving Eide Hard-Disk Drive Power Thermal Power-Off Asset TagSystem Data Options Assigning a System Password Using the System Password FeatureDeleting or Changing an Existing System Password Type the password and press EnterUsing the Setup Password Feature Assigning a Setup PasswordOperating With a Setup Password Enabled Deleting or Changing an Existing Setup Password Disabling a Forgotten PasswordInformation on resetting the chassis intrusion detector Responding to Error MessagesQuick Start When to Run the ICU About the ICUICU Database Preparing to Use the ICU Accessing HelpStarting the ICU Backing Up the ICU DisketteKeyss Action Adding a Listed CardCard Configuration Dialog Box Adding an Unlisted Card Available Settings List BoxSpecify Interrupt Dialog Box Specify I/O Port Dialog Box Modifying a CardRemoving a Card Viewing Resources Saving the System ConfigurationExiting the ICU Locking and Unlocking CardsLocking and Unlocking All Resources Locking and Unlocking Configuration ResourcesPage NIC Connector and Indicators Connecting to a NetworkConfiguring the NIC Network Cable RequirementsWindows NT 4.0 NIC Driver Setting the Network Frame Type Manually Configuring a 3Com PCI 3C905b NICReinstallation Speakers Connecting Audio DevicesAdjusting Volume in Windows NT Adjusting VolumeMicrophones Record/Playback DevicesUsing Audio Utilities Adjusting 3D SoundInstalling Audio Drivers Muting the Internal SpeakerScsi Device Considerations Scsi Drivers for Windows NT Installing Scsi DriversPage Safety First-For You and Your Computer Before You BeginUnpacking Your Hardware Option Replacing the Computer Cover Removing the Computer CoverReplacing the Computer Cover Inside Your ComputerRotating the Power Supply Rotating the Power Supply Away From the System BoardExpansion Cards System Board FeaturesExpansion Slots Installing an Expansion CardRemoving the Filler Bracket Removing an Expansion CardAdding Memory Dimm Installation GuidelinesTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal See Using the System Setup Program Replacing the System BatterySystem Battery and Battery Socket Obtaining technical assistance Drive Locations Removing and Replacing the Front BezelRemoving and Replacing Front-Panel Inserts Connecting DrivesDC Power Cable Connector Installing a Drive in a 5.25-Inch Drive BayRemoving a Drive Inserting the New Drive Into the Drive Bay Eide Drive Addressing Installing an Eide Hard-Disk Drive10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Installing Scsi Devices Scsi Configuration GuidelinesScsi ID Numbers General Procedure for Installing Scsi Devices Device TerminationScsi Cables ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives Table A-1. Technical Specifications Processor System InformationExpansion Bus Ports and Connectors System ClocksDrives Key Combinations Controls and IndicatorsPhysical Page Jumpers and Switches-A General Explanation SwitchesJumpers Reserved do not remove jumper PARALLEL/SCSI System Board LabelsSerial and Parallel Ports Ports and ConnectorsSerial Port Connectors Parallel Port Connector Dparh External Scsi ConnectorKeyboard Connector Keyboard and Mouse ConnectorsVideo Connector NIC ConnectorMouse Connector Microphone Jack USB ConnectorsLine-Out Jack Interrupt AssignmentsLine-In Jack Table B-9. Interrupt Assignments IRQ Line Used By/AvailableTable B-10. Conventional Memory Map Address Range Use Memory AllocationsTable B-11. Upper Memory Map Address Range Use ICU Error Messages Table C-1. Configuration Utility Messages Probable CauseCorrective Action Listed Card or Adding an Unlisted Card for instructions Configuration Manager Messages Table C-2. Configuration Manager MessagesChange to the db subdirectory on the diskette drive Page Cards mentioned Page Backup Devices Scheduling BackupsRecovering Data Data PreservationCleaning System Components Recommended Tools and AccessoriesCleaning the Computer, Monitor, and Keyboard Exteriors Temperature Cleaning DrivesEnvironmental Factors HumidityDust and Particles AltitudeCorrosion ESDPower Source Interruptions MagnetismShock and Vibration Power Protection Devices Overview FCC Notices U.S. Only IC Notice Canada OnlyClass a Class B EN 55022 Compliance Czech Republic Only CE Notice European UnionVcci Notice Japan Only Class a ITEMOC Notice South Korea Only Class B ITEClass a Device Class B Device Polish Center for Testing and Certification NoticeExporter NOM Information Mexico OnlyOne Dell Way Round Rock, TXInformación para NOM únicamente para México Overview Limited Three-Year Warranty U.S. and Canada Only Coverage During Year OneCoverage During Years Two and Three General Total Satisfaction Return Policy U.S. and Canada OnlyADI AcpiAGP AsciiAspi AsicBBS BiosBTU Cmos CD-ROMDAT CPUDIN DimmDIP DMADpms DmtfDram DTEECP ECCEeprom EideEMS EpromFAT FTP FCCHMA GUIHpfs IcesIRQ IPXISA ITEXMM LANLVD LED
Related manuals
Manual 96 pages 49.66 Kb Manual 230 pages 48.24 Kb