Dell 610 technical specifications Adding Memory, Dimm Installation Guidelines

Page 62

1.If you are removing a non-Plug and Play ISA expansion card, enter the ICU and remove the expansion card from your configuration.

See "Using the ISA Configuration Utility" for instructions.

2.Remove the computer cover according to the instructions in See "Removing the Computer Cover".

CAUTION: See "Protecting Against Electrostatic Discharge".

3.If necessary, disconnect any cables connected to the card.

4.Unscrew the mounting bracket of the card you want to remove.

5.Grasp the card by its outside corners, and ease it out of its connector.

6.If you are removing the card permanently, install a metal filler bracket over the empty card-slot opening.

NOTE: Installing filler brackets over empty card-slot openings is necessary to maintain Federal Communications Commission (FCC) certification of the system. The brackets also keep dust and dirt out of your computer.

7. Replace the computer cover, and reconnect your computer and peripherals to their power sources and turn them on.

NOTE: After you remove and replace the cover, the chassis intrusion detector will cause the following message to be displayed at the next system start-up:

ALERT! Cover was previously removed.

8.To reset the chassis intrusion detector, enter the System Setup program and reset Chassis Intrusion to Not Detected. See "Using the System Setup Program" for instructions.

NOTE: If a setup password has been assigned by someone else, contact your network administrator for information on resetting the chassis intrusion detector.

Adding Memory

Dell Precision 610 systems can use unbuffered or registered synchronous dynamic random-access memory (SDRAM) modules that provide error checking and correction (ECC) capabilities.

System memory can be increased up to 512 megabytes (MB) using unbuffered SDRAM dual in-line memory modules (DIMMs) or up to 2048 MB using registered SDRAM DIMMs (see Tables 9-1 and 9-2). Unbuffered and registered SDRAM DIMMs cannot be mixed.

Figure 9-5 shows the DIMMs and DIMM sockets.

Figure 9-5. DIMMs and DIMM Sockets

DIMM Installation Guidelines

When adding system memory, you may install DIMMs in any order. For optimum operation, Dell recommends installing the DIMMs starting with socket A (closest to the top edge of the system board) and working toward socket D, leaving no open sockets between installed DIMMs.

Tables 9-1 and 9-2 list sample memory configurations.

Table 9-1. Sample Unbuffered SDRAM DIMM Configuration Options

Image 62
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge System Features OverviewPage Page Reinstalling Windows NT Important Note to Windows NT 4.0 UsersCreating Disk Partitions for Windows NT Front PanelBack Panel Security Cable Slot and Padlock Ring Connecting External DevicesGetting Help Software Support Utilities on Diskette Dell-Installed Software Support UtilitiesBacking Up the Software Support Utilities Asset Tag Utility System Utilities and ServicesRemoving a Service Asset 1234$ABCD Dell AutoShutdown ServiceAssigning and Deleting an Asset Tag Number Assigning and Deleting an Owner TagInstalling the Auto Power On Utility Dell ThermalShutdown ServiceAuto Power On Utility Microsoft Updated Atapi Drivers Removing the Windows NT 4.0 Microsoft Updated Atapi DriverEntering the System Setup Program System Setup ScreenUsing the System Setup Program System-Setup Navigation Keys Keys ActionSystem Setup Options System TimePrimary Drive and Secondary Drive System DateDiskette Drive a and Diskette Drive B Eide DevicesHard-Disk Drive Sequence Boot SequenceIf You Have a Problem If You Know the Drive-Type NumberCPU Speed System MemoryReserved Memory PXENIC CPU IDsIntegrated Devices Diskette Interface Parallel Port ModeIDE Drive Interface PC SpeakerSetup Password System PasswordPassword Status System SecurityKeyboard NumLock Report Keyboard ErrorsAuto Power On Wakeup On LANSaving Eide Hard-Disk Drive Power Power ManagementSaving Monitor Power System Data Options Thermal Power-OffAsset Tag Using the System Password Feature Assigning a System PasswordType the password and press Enter Deleting or Changing an Existing System PasswordOperating With a Setup Password Enabled Using the Setup Password FeatureAssigning a Setup Password Disabling a Forgotten Password Deleting or Changing an Existing Setup PasswordResponding to Error Messages Information on resetting the chassis intrusion detectorQuick Start ICU Database When to Run the ICUAbout the ICU Starting the ICU Accessing HelpPreparing to Use the ICU Backing Up the ICU DisketteAdding a Listed Card Keyss ActionCard Configuration Dialog Box Available Settings List Box Adding an Unlisted CardSpecify Interrupt Dialog Box Modifying a Card Specify I/O Port Dialog BoxRemoving a Card Exiting the ICU Saving the System ConfigurationViewing Resources Locking and Unlocking CardsLocking and Unlocking Configuration Resources Locking and Unlocking All ResourcesPage Connecting to a Network NIC Connector and IndicatorsWindows NT 4.0 NIC Driver Configuring the NICNetwork Cable Requirements Manually Configuring a 3Com PCI 3C905b NIC Setting the Network Frame TypeReinstallation Connecting Audio Devices SpeakersMicrophones Adjusting VolumeAdjusting Volume in Windows NT Record/Playback DevicesInstalling Audio Drivers Adjusting 3D SoundUsing Audio Utilities Muting the Internal SpeakerScsi Device Considerations Installing Scsi Drivers Scsi Drivers for Windows NTPage Unpacking Your Hardware Option Safety First-For You and Your ComputerBefore You Begin Removing the Computer Cover Replacing the Computer CoverInside Your Computer Replacing the Computer CoverRotating the Power Supply Away From the System Board Rotating the Power SupplySystem Board Features Expansion CardsInstalling an Expansion Card Expansion SlotsRemoving an Expansion Card Removing the Filler BracketDimm Installation Guidelines Adding MemoryTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal Replacing the System Battery See Using the System Setup ProgramSystem Battery and Battery Socket Obtaining technical assistance Removing and Replacing the Front Bezel Drive LocationsConnecting Drives Removing and Replacing Front-Panel InsertsInstalling a Drive in a 5.25-Inch Drive Bay DC Power Cable ConnectorRemoving a Drive Inserting the New Drive Into the Drive Bay Installing an Eide Hard-Disk Drive Eide Drive Addressing10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Scsi ID Numbers Installing Scsi DevicesScsi Configuration Guidelines Scsi Cables General Procedure for Installing Scsi DevicesDevice Termination ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives Expansion Bus Table A-1. Technical Specifications ProcessorSystem Information Drives Ports and ConnectorsSystem Clocks Controls and Indicators Key CombinationsPhysical Page Jumpers Jumpers and Switches-A General ExplanationSwitches Reserved do not remove jumper System Board Labels PARALLEL/SCSIPorts and Connectors Serial and Parallel PortsSerial Port Connectors Parallel Port Connector External Scsi Connector DparhKeyboard and Mouse Connectors Keyboard ConnectorMouse Connector Video ConnectorNIC Connector USB Connectors Microphone JackLine-In Jack Interrupt AssignmentsLine-Out Jack Table B-9. Interrupt Assignments IRQ Line Used By/AvailableMemory Allocations Table B-10. Conventional Memory Map Address Range UseTable B-11. Upper Memory Map Address Range Use Corrective Action ICU Error MessagesTable C-1. Configuration Utility Messages Probable Cause Listed Card or Adding an Unlisted Card for instructions Change to the db subdirectory on the diskette drive Configuration Manager MessagesTable C-2. Configuration Manager Messages Page Cards mentioned Page Recovering Data Scheduling BackupsBackup Devices Data PreservationCleaning the Computer, Monitor, and Keyboard Exteriors Cleaning System ComponentsRecommended Tools and Accessories Environmental Factors Cleaning DrivesTemperature HumidityCorrosion AltitudeDust and Particles ESDShock and Vibration Power Source InterruptionsMagnetism Power Protection Devices Overview Class a Class B FCC Notices U.S. OnlyIC Notice Canada Only Vcci Notice Japan Only CE Notice European UnionEN 55022 Compliance Czech Republic Only Class a ITEClass a Device MOC Notice South Korea OnlyClass B ITE Polish Center for Testing and Certification Notice Class B DeviceOne Dell Way NOM Information Mexico OnlyExporter Round Rock, TXInformación para NOM únicamente para México Coverage During Years Two and Three Overview Limited Three-Year Warranty U.S. and Canada OnlyCoverage During Year One Total Satisfaction Return Policy U.S. and Canada Only GeneralAGP AcpiADI AsciiAsic AspiBios BBSBTU CD-ROM CmosCPU DATDIP DimmDIN DMADram DmtfDpms DTEEeprom ECCECP EideFAT EMSEprom FCC FTPHpfs GUIHMA IcesISA IPXIRQ ITELAN XMMLED LVD