Dell 610 technical specifications Serial Port Connectors

Page 92

designation.

Both the new and the remapped COM ports share the same IRQ setting, as follows:

COM1, COM3: IRQ4 (shared setting)

COM2, COM4: IRQ3 (shared setting)

These COM ports have the following I/O address settings:

COM1: 3F8h

COM2: 2F8h

COM3: 3E8h

COM4: 2E8h

For example, if you add an internal modem card with a port configured as COM1, the computer then see s logical COM1 as the address on the modem card. It automatically remaps the built-in serial port that was designated as COM1 to COM3, which shares the COM1 IRQ setting. (Note that when you have two COM ports sharing an IRQ setting, you can use either port as necessary but you may not be able to use them both at the same time.) If you install one or more expansion cards with serial ports designated as COM1 and COM3, the corresponding built-in serial port is disabled, as described in "Serial Port 1 and Serial Port 2".

Before adding a card that remaps the COM ports, check the documentation that accompanied your software to make sure that the software can be mapped to the new COM port designation.

To avoid autoconfiguration, you may be able to reset the expansion card's jumpers or switches so that its port designation changes to the next available COM number, leaving the designation for the built-in port as is. Alternatively, you can disable the built-in ports through the System Setup program. The documentation for your expansion card should provide the card's default I/O address and allowable IRQ settings. It should also provide instructions for readdressing the port and changing the IRQ setting if necessary.

The built-in parallel port has autoconfiguration capability through the System Setup program. That is, if you set the parallel port to its automatic configuration and add an expansion card containing a port configured as LPT1 (IRQ7, I/O address 378h), the system automatically remaps the built-in parallel port to its secondary address (IRQ5, I/O address 278h). If the secondary port address is already being used, the built-in parallel port is turned off. For more information, see "Parallel Port".

For general information on how your operating system handles serial and parallel ports as well as for more detailed command procedures, see your operating system documentation.

Serial Port Connectors

If you reconfigure your hardware, you may need pin number and signal information for the serial port connectors. Figure B-3 illustrates the pin numbers for the serial port connectors, and Table B-3 lists and defines the pin assignments and interface signals for the serial port connectors.

Figure B-3. Pin Numbers for the Serial Port Connectors

Table B-3. Pin Assignments for the Serial Port Connectors

Pin

Signal

I/O

Definition

1

DCD

I

Data carrier detect

2

SIN

I

Serial input

3

SOUT

O

Serial output

Image 92
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge System Features OverviewPage Page Reinstalling Windows NT Important Note to Windows NT 4.0 UsersCreating Disk Partitions for Windows NT Front PanelBack Panel Security Cable Slot and Padlock Ring Connecting External DevicesGetting Help Software Support Utilities on Diskette Dell-Installed Software Support UtilitiesBacking Up the Software Support Utilities Asset Tag Utility System Utilities and ServicesRemoving a Service Dell AutoShutdown Service Assigning and Deleting an Asset Tag NumberAsset 1234$ABCD Assigning and Deleting an Owner TagInstalling the Auto Power On Utility Dell ThermalShutdown ServiceAuto Power On Utility Microsoft Updated Atapi Drivers Removing the Windows NT 4.0 Microsoft Updated Atapi DriverEntering the System Setup Program System Setup ScreenUsing the System Setup Program System-Setup Navigation Keys Keys ActionSystem Setup Options System TimeSystem Date Diskette Drive a and Diskette Drive BPrimary Drive and Secondary Drive Eide DevicesBoot Sequence If You Have a ProblemHard-Disk Drive Sequence If You Know the Drive-Type NumberSystem Memory Reserved MemoryCPU Speed PXENIC CPU IDsIntegrated Devices Parallel Port Mode IDE Drive InterfaceDiskette Interface PC SpeakerSystem Password Password StatusSetup Password System SecurityReport Keyboard Errors Auto Power OnKeyboard NumLock Wakeup On LANSaving Eide Hard-Disk Drive Power Power ManagementSaving Monitor Power System Data Options Thermal Power-OffAsset Tag Using the System Password Feature Assigning a System PasswordType the password and press Enter Deleting or Changing an Existing System PasswordOperating With a Setup Password Enabled Using the Setup Password FeatureAssigning a Setup Password Disabling a Forgotten Password Deleting or Changing an Existing Setup PasswordResponding to Error Messages Information on resetting the chassis intrusion detectorQuick Start ICU Database When to Run the ICUAbout the ICU Accessing Help Preparing to Use the ICUStarting the ICU Backing Up the ICU DisketteAdding a Listed Card Keyss ActionCard Configuration Dialog Box Available Settings List Box Adding an Unlisted CardSpecify Interrupt Dialog Box Modifying a Card Specify I/O Port Dialog BoxRemoving a Card Saving the System Configuration Viewing ResourcesExiting the ICU Locking and Unlocking CardsLocking and Unlocking Configuration Resources Locking and Unlocking All ResourcesPage Connecting to a Network NIC Connector and IndicatorsWindows NT 4.0 NIC Driver Configuring the NICNetwork Cable Requirements Manually Configuring a 3Com PCI 3C905b NIC Setting the Network Frame TypeReinstallation Connecting Audio Devices SpeakersAdjusting Volume Adjusting Volume in Windows NTMicrophones Record/Playback DevicesAdjusting 3D Sound Using Audio UtilitiesInstalling Audio Drivers Muting the Internal SpeakerScsi Device Considerations Installing Scsi Drivers Scsi Drivers for Windows NTPage Unpacking Your Hardware Option Safety First-For You and Your ComputerBefore You Begin Removing the Computer Cover Replacing the Computer CoverInside Your Computer Replacing the Computer CoverRotating the Power Supply Away From the System Board Rotating the Power SupplySystem Board Features Expansion CardsInstalling an Expansion Card Expansion SlotsRemoving an Expansion Card Removing the Filler BracketDimm Installation Guidelines Adding MemoryTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal Replacing the System Battery See Using the System Setup ProgramSystem Battery and Battery Socket Obtaining technical assistance Removing and Replacing the Front Bezel Drive LocationsConnecting Drives Removing and Replacing Front-Panel InsertsInstalling a Drive in a 5.25-Inch Drive Bay DC Power Cable ConnectorRemoving a Drive Inserting the New Drive Into the Drive Bay Installing an Eide Hard-Disk Drive Eide Drive Addressing10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Scsi ID Numbers Installing Scsi DevicesScsi Configuration Guidelines Scsi Cables General Procedure for Installing Scsi DevicesDevice Termination ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives Expansion Bus Table A-1. Technical Specifications ProcessorSystem Information Drives Ports and ConnectorsSystem Clocks Controls and Indicators Key CombinationsPhysical Page Jumpers Jumpers and Switches-A General ExplanationSwitches Reserved do not remove jumper System Board Labels PARALLEL/SCSIPorts and Connectors Serial and Parallel PortsSerial Port Connectors Parallel Port Connector External Scsi Connector DparhKeyboard and Mouse Connectors Keyboard ConnectorMouse Connector Video ConnectorNIC Connector USB Connectors Microphone JackInterrupt Assignments Line-Out JackLine-In Jack Table B-9. Interrupt Assignments IRQ Line Used By/AvailableMemory Allocations Table B-10. Conventional Memory Map Address Range UseTable B-11. Upper Memory Map Address Range Use Corrective Action ICU Error MessagesTable C-1. Configuration Utility Messages Probable Cause Listed Card or Adding an Unlisted Card for instructions Change to the db subdirectory on the diskette drive Configuration Manager MessagesTable C-2. Configuration Manager Messages Page Cards mentioned Page Scheduling Backups Backup DevicesRecovering Data Data PreservationCleaning the Computer, Monitor, and Keyboard Exteriors Cleaning System ComponentsRecommended Tools and Accessories Cleaning Drives TemperatureEnvironmental Factors HumidityAltitude Dust and ParticlesCorrosion ESDShock and Vibration Power Source InterruptionsMagnetism Power Protection Devices Overview Class a Class B FCC Notices U.S. OnlyIC Notice Canada Only CE Notice European Union EN 55022 Compliance Czech Republic OnlyVcci Notice Japan Only Class a ITEClass a Device MOC Notice South Korea OnlyClass B ITE Polish Center for Testing and Certification Notice Class B DeviceNOM Information Mexico Only ExporterOne Dell Way Round Rock, TXInformación para NOM únicamente para México Coverage During Years Two and Three Overview Limited Three-Year Warranty U.S. and Canada OnlyCoverage During Year One Total Satisfaction Return Policy U.S. and Canada Only GeneralAcpi ADIAGP AsciiAsic AspiBios BBSBTU CD-ROM CmosCPU DATDimm DINDIP DMADmtf DpmsDram DTEECC ECPEeprom EideFAT EMSEprom FCC FTPGUI HMAHpfs IcesIPX IRQISA ITELAN XMMLED LVD
Related manuals
Manual 96 pages 49.66 Kb Manual 230 pages 48.24 Kb